User manual DAIKIN EKRTETS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN EKRTETS. We hope that this DAIKIN EKRTETS user guide will be useful to you.


DAIKIN EKRTETS : Download the complete user guide (455 Ko)

Manual abstract: user guide DAIKIN EKRTETS

Detailed instructions for use are in the User's Guide.

[. . . ] Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 EKRTR + EKRTETS Room thermostat 4PW56106-1 Operation manual 1 1. Introduction The EKRTR is a state of the art programmable electronic thermostat, which regulates your Daikin system, where comfort, simplicity and energy saving go hand in hand. [. . . ] Use this mode for a fixed temperature on reduced level (reduced setpoint default on 17. 0°C/63. 0°F in heating mode, 28. 0°C/82. 5°F in cooling mode). Integrated frost protection remains activated (frost protection default on 4. 0°C/39. 5°F in heating mode). B C D Operation manual 8 EKRTR + EKRTETS Room thermostat 4PW56106-1 5. 2. Modes and menus in the advanced menu E F G To activate advanced modes, navigate to OFF mode (D) and press > during 5 seconds. Use this menu to choose a factory-defined schedule or create a custom one. Use this menu to set date and time. F G EKRTR + EKRTETS Room thermostat 4PW56106-1 Operation manual 9 6. Using the key lock function k Activate or deactivate the key lock function by pressing + and - at the same time. Activating the schedule timer For full comfort with limitation of energy consumption you can pick an ideal schedule for each day. This makes sure the temperature is in the comfort mode when you are at home and that the temperature is automatically reduced at times you are sleeping, at work and so on. 1 2 3 If needed, activate the advanced mode by pressing > during 5 seconds in OFF mode (D). Navigate to the schedule timer setting menu (F) by pressing >. Select the desired schedule by pressing + or -. The possible schedules are: 2 user-defined (1+2) and 5 factory-defined (1~5). The factory-defined schedules are described in "APPENDIX: factory-defined programs" on page 22. For the user-defined schedules, refer to "Setting up a user-defined schedule" on page 13. Press + and - to consult the programmed actions, press < and > to consult the other days (if already programmed). Optionally, press = to lock the schedule timer mode (S). 4 5 6 Operation manual 10 EKRTR + EKRTETS Room thermostat 4PW56106-1 NOTE For your optimum comfort, the schedule timer can be set to start up in advance (120 minutes, code 2® 02, for 4. 0° setpoint difference), trying to reach the programmed setpoint at the programmed time. This control can be enabled or disabled by means of code 2® 01 in the user menu. Refer to "Setting up codes in the user menu" on page 16. EKRTR + EKRTETS Room thermostat 4PW56106-1 Operation manual 11 6. 3. Manually overriding a schedule There are 2 ways of overriding a schedule: S A temporary override in locked schedule timer mode (S) Temporarily choose the comfort or reduced setpoint by pressing 1 button only: < or >. · reduced setpoint: w and h are displayed. A temporary override of the setpoint in schedule timer mode Press + or - to modify the setpoint in steps of 0. 5°C/0. 5°F. Locking and unlocking the schedule timer mode is performed by pressing =. The unlocked schedule timer mode displays as B. NOTE By default the manual override is active until the next scheduled action. You can change this behavior by means of user code 2® 03: the manual override will then only be active for 1 hour. Refer to "Setting up codes in the user menu" on page 16. Operation manual 12 EKRTR + EKRTETS Room thermostat 4PW56106-1 6. 4. Setting up a user-defined schedule (1 and 2) Within the user-defined schedule each day can be programmed individually and 12 actions (setpoints) are possible per day. First decide upon the temperature scale you prefer (°C/°F) by setting up code 1® 01 as decribed in "Setting up codes in the user menu" on page 16. [. . . ] Disposal requirements The batteries supplied with the thermostat are marked with this symbol. This means that the batteries shall not be mixed with unsorted household waste. If a chemical symbol is printed beneath the symbol, this means that the battery contains a heavy metal above a certain concentration. Waste batteries must be treated at a specialized treatment facility for re-use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN EKRTETS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN EKRTETS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.