User manual DAIKIN FAQ71BVV1B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN FAQ71BVV1B. We hope that this DAIKIN FAQ71BVV1B user guide will be useful to you.


DAIKIN FAQ71BVV1B : Download the complete user guide (1187 Ko)

Manual abstract: user guide DAIKIN FAQ71BVV1B

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATION MANUAL English SPLIT SYSTEM MODELS (Wall mounted type) Air Conditioner Deutsch Franais FAQ71BUV1B FAQ71BVV1B Espaol Italiano Nederlands Portugues d j a h f e g i b c d e f k [1] Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. Operation: see the remote controller operation manual for details on the names and functions of switches and displays on the remote controller. Daikin. [. . . ] Check and make sure that foundation blocks are not damaged after a long use. If they are left in a damaged condition, the unit may fall and result in injury. 2 English Neither place a flammable spray bottle near the air conditioner nor perform spraying. To clean the air conditioner, stop operation, and unplug the power cord from the outlet. Do not place items that might be damaged by water under the indoor unit. Water may condensate and drip if the humidity reaches 80% or if the drain exit gets clogged. Do not place a burner or heater at a place directly exposed to the wind from the air conditioner. Do not allow a child to mount on the outdoor unit or avoid placing any object on it. Do not install the air conditioner at any place where flammable gas may leak out. If the gas leaks out and stays around the air conditioner, a fire may break out. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. Consult with installation contractor for cleaning the inside of the air conditioner. Wrong cleaning may make the plastics parts broken or cause failure of water leakage or electric shock. Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts. 3. OPERATION RANGE If the temperature or the humidity is beyond the following conditions, safety devices may work and the air conditioner may not operate, or sometimes, water may drop from the indoor unit. COOLING OUTDOOR UNIT RZQ71140 RQ71 RR71 HEATING OUTDOOR UNIT RZQ71140 RQ71 INDOOR TEMPERATURE DB DB 10 to 27 10 to 27 OUTDOOR TEMPERATURE DB 19. 5 to 21 WB 20 to 15. 5 DB 9 to 21 WB 10 to 15 INDOOR TEMPERAHUMIDITY TURE DB 18 to 37 80% or below WB 12 to 28 DB 18 to 37 80% or below WB 12 to 28 DB 18 to 37 WB 12 to 28 80% or below OUTDOOR TEMPERATURE DB 15 to 50 DB 5 to 46 DB 15 to 46 For Australia model Only COOLING OUTDOOR UNIT RZQ71 HEATING OUTDOOR UNIT RZQ71 INDOOR TEMPERATURE DB 10 to 27 OUTDOOR TEMPERATURE DB 14 to 21 WB 15 to 15. 5 INDOOR OUTDOOR TEMPERAHUMIDITY TEMPERATURE TURE DB 20 to 37 80% or DB 5 to 46 below WB 14 to 28 D B: Dry bulb temperature WB: Wet bulb temperature The setting temperature range of the remote controller is 16C to 32C. English 3 4. INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well-ventilated place where there are no obstacles around?a. Filled with much mineral oil such as cutting oil b. Where there is much salt such as a beach area c. Where sulfured gas exists such as a hot-spring resort d. Where there are considerable voltage fluctuations such as a factory or plant e. Vehicles and vessels f . Where there is much spray of oil and vapor such as a cookery, etc. g. Where there are machines generating electromagnetic waves h. Filled with acid and/or alkaline steam or vapor Is a snow protection measure taken?OPERATION PROCEDURE Read the operation manual that came with the remote controller. Operating procedure varies with heat pump type and cooling only type. [. . . ] VIII. THE LIQUID CRYSTAL OF THE REMOTE CONTROLLER SHOW " " It happens immediately after the main power supply switch is turned on. When the room temperature reaches the set temperature in heating mode, the outdoor unit stops and the indoor unit switches to whisper mode. This is to prevent the cool air from being blown directly onto anyone in the room. WHITE MIST COMES OUT OF A UNIT When humidity is high during cooling operation (In oily or dusty places) If the inside of an indoor unit is extremely contaminated, the temperature distribution inside a room becomes uneven. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN FAQ71BVV1B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN FAQ71BVV1B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.