User manual DAIKIN FTXG25JV1BS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAIKIN FTXG25JV1BS. We hope that this DAIKIN FTXG25JV1BS user guide will be useful to you.


DAIKIN FTXG25JV1BS : Download the complete user guide (3143 Ko)

Manual abstract: user guide DAIKIN FTXG25JV1BS

Detailed instructions for use are in the User's Guide.

[. . . ] 11 HOME LEAVE VENTILATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TIMER Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 COMFORT SLEEP Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 POWERFUL Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 SET UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 MOLD PROOF Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 MOLD SHOCK OUT Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 INFORMATION DISPLAY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 CARE Care and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TROUBLE SHOOTING Trouble Shooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 1 English Safety Precautions READ BEFORE OPERATION · · · · Keep this manual where the operator can easily find them. For safety reason the operator must read the following cautions carefully. Be sure to follow all precautions below: they are all important for ensuring safety. WARNING CAUTION Never do. If you do not follow these instructions exactly, the unit may cause property damage, personal injury or loss of life. If you do not follow these instructions exactly, the unit may cause minor or moderate property damage or personal injury. Be sure to follow the instructions. Be sure to earth the air conditioner. Never cause the air conditioner (including the remote controller) to get wet. Never touch the air conditioner (including the remote controller) with a wet hand. WARNING · In order to avoid fire, explosion or injury, do not operate the · · · unit when harmful, among which flammable or corrosive gases, are detected near the unit. [. . . ] The time from 0. 5 to 9. 5 hours can be set. ON/OFF TIMER operation Set time for ON TIMER or OFF TIMER. (page 6. ) · The present time display disappears when the time ON/OFF TIMER is reserved. 2. Press " TIMER. * OFF TIMER " for OFF TIMER and press " is displayed. Press " " to set the time to be reserved. 3 · Pressing the button changes the time in 10 minutes. Press " TIMER. " for OFF TIMER and press " " for ON 2, 4 5 The displayed time is set. Orange * OFF TIMER To cancel the TIMER operation 5. Press " ". · The TIMER lamp will go off and the TIMER will be canceled. NOTE In the following cases, set the timer again. Note on TIMER operation · Starting COUNTDOWN OFF TIMER and OFF TIMER causes the unit to automatically change the set temperature 1 hour later to prevent the room from becoming too cold or too hot. (Turns up 0. 5°C during COOLING or DRY COOLING and turns down 2°C during HEATING or HUMID HEATING. ) · Reserving the ON TIMER will cause the unit to start running up to 1 hour before, in order to make sure the temperature reaches the temperature set on the remote controller by the set time. · When operating the unit via the COUNTDOWN OFF TIMER or OFF TIMER, the (Example) actual length of operation may vary from the time entered by the user. · Once you set ON/OFF TIMER, the time setting is kept in the memory. You want to have the unit run for 1 more hour and However, the COUNTDOWN OFF TIMER does not have this memory function. (page 15. ) MONITOR BRIGHTNESS HIGH BEEP volume CONTRAST Setting Setting complete LOW 1 LOW HIGH 6 OFF OFF 16 · Changes the brightness of the indoor unit display. 3 1, 2 · Sets the receiving tone volume. · Sets the grayscale for the remote controller LCD. · Selectable from contrast 1 to 16. : The display on the remote control goes back to normal if no setting is made for 10 seconds. NOTE Note on CHILD PROOF LOCK · Selecting "ON" while CHILD PROOF LOCK setting and then pressing " PROOF LOCK to be enabled and the display to show " ". " or making no setting for 10 seconds will cause the CHILD · The button operations other than " " are disabled in CHILD PROOF LOCK mode. · To cancel the CHILD PROOF LOCK, set to "OFF" following the above steps from 1 to 3. English 14 MOLD PROOF Operation Dries the inside of the unit to prevent mold and odors. Movement during MOLD PROOF operation Stop COOLING, DRY COOLING, and "SARARA" DRYING operations PREDRYING [FAN] HEATING with the internal fan off FAN HEATING <Color of multi-colored indicator lamp> Purple Blue Blinks alternately. Blue Light blue Blinks alternately. Light blue White Blinks alternately. White Operation complete Auto operation (approximately once every 2 weeks) If the unit is set to "MOLD PROOF ON", the MOLD PROOF operation will start automatically after the unit has been run in "SARARA" DRYING or COOLING mode, depending on the amount of time the unit has been run (approximately once every 2 weeks). (page 14. ) The default is set to "MOLD PROOF OFF". 1, 2 Manual operation 1. " for about 2 seconds while the unit is not The MOLD PROOF operation will start. The display will return to normal. (In case of manual operation) · The front panel and horizontal louver will open. · The MOLD PROOF operation runs for 2-3 hours, changing the color of the multicolored indicator lamp of the unit. If you want to stop MOLD PROOF operation during operation 2. Hold " " (again) for about 2 seconds. · The front panel and horizontal louver will close. · The multi-colored indicator of the unit will go off. NOTE Note on MOLD PROOF operation · Dries out the interior of the air conditioner using FAN and HEATING operation mode to exhaust humidity to the outdoor. · During MOLD PROOF operation, the room temperature may rise and humidity from the machine may be sent into the room. · The mode may not be used if the outside temperature or humidity is very high. [. . . ] · The air conditioner may malfunction with lightning or radio waves. Turn the breaker OFF, turn it ON again and try operating the air conditioner with the remote controller. (Multi-colored indicator lamp flashes. ) The multi-colored indicator lamp flashes for a certain amount of time (about 2 minutes) at the start of or during FLASH STREAMER AIR PURIFYING operation. · Is there something caught in the front panel? Remove the object and attempt operation again using the remote controller. If the panel still does not open, contact your dealer if the operation lamp is still flashing. · Is the streamer unit installed securely? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN FTXG25JV1BS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN FTXG25JV1BS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.