User manual DATALOGIC MAGELLAN 1000I

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 1000I. We hope that this DATALOGIC MAGELLAN 1000I user guide will be useful to you.


DATALOGIC MAGELLAN 1000I : Download the complete user guide (872 Ko)

Manual abstract: user guide DATALOGIC MAGELLAN 1000I

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 1000i Omni-Directional Imaging Scanner Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set ACK Character, " followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the "START/END" barcode above. DEFAULT SETTING FOR THIS FEATURE: 006 Set ACK Character NAK Character START / END PROGRAMMING BARCODES Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in "005". To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set NAK Character, " followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the "START/END" barcode above. DEFAULT SETTING FOR THIS FEATURE: 021 Set NAK Character 3-20 Magellan® 1000i Interface Features RS-232 Interface Features -- cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired. START / END PROGRAMMING BARCODES Disable Retry on ACK NAK Timeout Enable Retry on ACK NAK Timeout DEFAULT ACK NAK Timeout Value START / END PROGRAMMING BARCODES This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. 000 = Infinite timeout 001 - 075 = Timeout in 200-millisecond increments To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set ACK NAK Timeout Value, " followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired value. Exit programming mode by again scanning the "START/END" barcode above. DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec) Set ACK NAK Timeout Value Product Reference Guide 3-21 Interface Related Features RS-232 Interface Features -- cont. ACK NAK Retry Count START / END PROGRAMMING BARCODES This feature sets the number of times for the scanner to retry a label transmission under a retry condition. 000 = No retry 001 - 254 = Retry for the specified number of times 255 = Retry forever To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set ACK NAK Retry Count, " followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired retry count. Exit programming mode by again scanning the "START/END" barcode above DEFAULT SETTING FOR THIS FEATURE: 003 Set ACK NAK Timeout Value 3-22 Magellan® 1000i Interface Features ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data) START / END PROGRAMMING BARCODES Ignore Errors Detected DEFAULT Process error as valid ACK character Process error as valid NAK character Product Reference Guide 3-23 Interface Related Features RS-232 Interface Features -- cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure. START / END PROGRAMMING BARCODES Disable Transmission Error Indication Enable Transmission Error Indication DEFAULT IBM-USB Interface Features IBM-USB Device usage The IBM-USB protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are: · · Table Top Scanner Handheld Scanner START / END PROGRAMMING BARCODES Configure as Table Top Scanner Configure as Handheld Scanner DEFAULT 3-24 Magellan® 1000i Interface Features IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for IBM USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B. START / END PROGRAMMING BARCODES Disable Convert to Code 39 DEFAULT Enable Convert to Code 39 Product Reference Guide 3-25 Interface Related Features Wand Emulation Supported Symbologies The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code symbologies: · · · · · · · UPC/EAN UPC/EAN with addons Code 39 Full ASCII Code 39 Interleaved 2 of 5 Codabar Code 128 Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scanner will be transmitted as Code 128. Wand Emulation Bar Code Format The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners. · · · · · · · UPC-A bar codes must include all 12 digits. UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the check digit. [. . . ] The following tables list default exceptions by interface for the remaining available interfaces. Product Reference Guide D-1 IBM Interfaces IBM Interfaces include IBM-USB, IBM Port 9B, IBM Port5B and IBM Port17. Parameter IBM Interface Type Number of Host Transmit Buffers Label I. D. Transmission Suffix Characters Default Setting IBM Port 9B One Buffer Disable No Suffix RS-232 Wincor/Nixdorf Parameter Interface Type Number of Host Transmit Buffers RS-232 Parity RS-232 Hardware Control UPC-E Check Character Conversion UCC/EAN-128 Label ID Code 39 Label ID Code 93 Label ID Code 128 Label ID Codabar Label ID EAN-8 Label ID EAN-13 Label ID ISBN Label ID Interleaved 2 of 5 Label ID Standard 2 of 5 Label ID MSI/Plessey Label ID UPC-E Label ID RSS-14 Label ID RSS Expanded Label ID Default Setting RS-232-WN One Buffer Odd CTS Flow Control Disabled `P' `M' `L' `K' `N' `B' `A' `A' `I' `H' `O' `C' `E' `E' D-2 Magellan® 1000i Interface Default Exceptions Wand Emulation Parameter Interface Type Code 39 Start/Stop Character Transmission Default Setting Wand Emulation Enable Keyboards Keyboard interfaces include USB Keyboard and Keyboard Wedge A-Y. Parameter Keyboard Wedge Interface Type Label ID Transmission Default Setting USB Keyboard Disable Product Reference Guide D-3 NOTES D-4 Magellan® 1000i Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets. Keyboard Model Cross Reference TransScancode mission Set Protocol Func. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 1000I




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 1000I will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.