If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 1400I. We hope that this DATALOGIC MAGELLAN 1400I user guide will be useful to you.
Manual abstract: user guide DATALOGIC MAGELLAN 1400I
Detailed instructions for use are in the User's Guide.
[. . . ] Magellan® 1400i
Omni-Directional Imaging Scanner
Product Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data)
START / END PROGRAMMING BAR CODES Ignore Errors Detected DEFAULT
Process error as valid ACK character
Process error as valid NAK character
Product Reference Guide
3-23
Interface Related Features
RS-232 Interface Features -- cont.
Transmission Failure Indication
Enables/disables bad-label indication upon transmission failure.
START / END PROGRAMMING BAR CODES
Disable Transmission Error Indication
Enable Transmission Error Indication DEFAULT
IBM-USB Interface Features
IBM-USB Device usage
The IBM-USB protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are: · · Table Top Scanner Handheld Scanner
START / END PROGRAMMING BAR CODES Configure as Table Top Scanner
Configure as Handheld Scanner DEFAULT
3-24
Magellan® 1400i
Interface Features
IBM
IBM Transmit Labels in Code 39 Format
This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for IBM USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.
START / END PROGRAMMING BAR CODES Disable Convert to Code 39 DEFAULT
Enable Convert to Code 39
Product Reference Guide
3-25
Interface Related Features
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code symbologies: · · · · · · · UPC/EAN UPC/EAN with addons Code 39 Full ASCII Code 39 Interleaved 2 of 5 Codabar Code 128
Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scanner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners. · · · · · · · UPC-A bar codes must include all 12 digits. UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the check digit. Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start / stop characters. Codabar bar codes must include the start / stop characters, presented in the ABCD format. Interleaved 2 of 5 bar codes must have an even number of digits.
3-26
Magellan® 1400i
Interface Features
Wand Emulation -- cont.
Bar/Space Polarity
Low/High -- Black will be transmitted as a low voltage level (0 to +0. 7V) and space as high level (+2. 4 to +5. 25V). High/Low -- Black will be transmitted as a high voltage level (+2. 4 to +5. 25V) and space as low level (0 to +0. 7V).
START / END PROGRAMMING BAR CODES Bar/Space = Low/High
Bar/Space = High/Low DEFAULT
Wand Idle State
This feature specifies the level of the wand output signal when idle. TTL logic levels: High voltage level (+2. 4 to +5. 25V) Low voltage level (0 to +0. 7V).
START / END PROGRAMMING BAR CODES Wand Idle State = Low DEFAULT
Wand Idle State = High
Product Reference Guide
3-27
Interface Related Features
Wand Emulation -- cont.
Signal Speed
The speed of the transmission can be set. 330 microseconds 660 microseconds
START / END PROGRAMMING BAR CODES Signal Speed = 330mS
Signal Speed = 660mS DEFAULT
Transmit Trailing Noise
The transmission of noise pulses after the label may be enabled or disabled.
START / END PROGRAMMING BAR CODES
Disable Trailing Noise
Enable Trailing Noise DEFAULT
3-28
Magellan® 1400i
Interface Features
Wand Emulation -- cont.
Transmit Leading Noise
The transmission of noise pulses before the bar code may be enabled or disabled.
START / END PROGRAMMING BAR CODES Disable Leading Noise
Enable Leading Noise DEFAULT
Symbology Conversion
Wand Emulation can convert all bar codes to a single symbology. Choices are: No Conversion Convert to Code 39 Convert to Code 128
START / END PROGRAMMING BAR CODES No Symbology Conversion DEFAULT
Convert to C39
Convert to C128
Product Reference Guide
3-29
Interface Related Features
Keyboard Wedge
and
USB Keyboard
As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn't require any changes of software or hardware.
All of the options in this section apply to the Keyboard Wedge, however, only some apply to USB Keyboard. NOTE Keyboard Layout
The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual.
START / END PROGRAMMING BAR CODES USA DEFAULT
Belgium
Britain
Denmark
France
Germany
3-30
Magellan® 1400i
Interface Features
Keyboard Wedge -- cont.
START / END PROGRAMMING BAR CODES Italy
Norway
Portugal
Spain
Sweden
Switzerland
Japan 106 Key
Hungary
Czech
Product Reference Guide
3-31
Interface Related Features
Keyboard Wedge -- cont.
START / END PROGRAMMING BAR CODES Slovakia
Romania
Croatia
Poland
Caps Lock State
Specifies the format in which the scanner sends character data.
START / END PROGRAMMING BAR CODES Disable Caps Lock DEFAULT
Caps Lock "ON"
Shift Lock "ON"
3-32
Magellan® 1400i
Interface Features
Keyboard Wedge -- cont.
Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.
START / END PROGRAMMING BAR CODES Disable Power-on Simulation DEFAULT
³
Enable Power-on Simulation
³ 028901
Product Reference Guide
3-33
Interface Related Features
Keyboard Wedge -- cont.
Control Characters
Specifies how the scanner transmits ASCII control characters to the host. [. . . ] RS-232 Setting 1 Disable Don't Transmit Enable
Interface-Specific Exceptions
Page # 5-32 5-33 5-33
5-34
Enable
5-35
Disable Don't Transmit Variable Length 1 80 Disable Disable 1 Disable Disable Enable Variable Length 6 50 Disable 1
5-35
5-36 5-37 5-38 5-38 5-38 5-39 5-39 5-40 5-40 5-47 5-42 5-43 5-43 5-44 5-45
D-8
Magellan® 1400i
Standard Feature Defaults
Feature Disable/Enable Codabar Codabar Check Character Verification Codabar Check Character Transmit Codabar Length Control Codabar Length 1 Codabar Length 2 Codabar Quiet Zones Codabar Start/Stop Character Type Codabar Start/Stop Character Transmission Codabar Start/Stop Character Match Codabar Stitching Codabar Minimum Reads Disable/Enable Code 93 Code 93 Length Control Code 93 Length 1 Code 93 Length 2 Code 93 Stitching Code 93 Minimum Reads Disable/Enable MSI/ Plessey MSI/Plessey Check Digit Verification MSI/Plessey Check Digit Transmit
Std. RS-232 Setting Disable Disable Enable Variable Length 3 50 Don't Require Start/Stop Type: abcd/ abcd Enable
Interface-Specific Exceptions
Page # 5-46 5-46 5-47 5-48 5-49 5-49 5-49
5-50
5-50
Disable Disable 1 Disable Variable Length 1 50 Disable 1 Disable Disable 1-Digit
5-51 5-51 5-52 5-53 5-54 5-55 5-55 5-56 5-56 5-57 5-57 5-58
Product Reference Guide
D-9
Feature Number of Check Characters MSI/Plessey Length Control MSI/Plessey Length 1 MSI/Plessey Length 2 MSI/Plessey Stitching MSI/Plessey Minimum Reads Disable/Enable Standard 2 of 5 Std 2 of 5 Check Digit Verification Std 2 of 5 Check Digit Transmit Std 2 of 5 Length Control Std 2 of 5 Length 1 Std 2 of 5 Length 2 Standard 2 of 5 Stitching Std 2 of 5 Minimum Reads Disable/Enable PDF417 PDF417 Length Control PDF417 Length 1 PDF417 Length 2 PDF417 Minimum Reads
Std. RS-232 Setting 1 Check Character Variable Length 4 16 Disable 1 Disable Disable Enable Variable Length 8 50 Disable 1 Disable Variable Length 1 600 1
Interface-Specific Exceptions
Page # 5-58 5-65 5-60 5-60 5-61 5-62 5-63 5-63 5-64 5-65 5-66 5-66 5-67 5-68 5-69 5-70 5-71 5-71 5-69
D-10
Magellan® 1400i
Appendix E
Keyboard Function Key Mappings
Keyboard Model Cross Reference
Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 1400I
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 1400I will begin.