User manual DATALOGIC MAGELLAN 1400I

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 1400I. We hope that this DATALOGIC MAGELLAN 1400I user guide will be useful to you.


DATALOGIC MAGELLAN 1400I : Download the complete user guide (920 Ko)

Manual abstract: user guide DATALOGIC MAGELLAN 1400I

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 1400i Omni-Directional Imaging Scanner Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data) START / END PROGRAMMING BAR CODES Ignore Errors Detected DEFAULT Process error as valid ACK character Process error as valid NAK character Product Reference Guide 3-23 Interface Related Features RS-232 Interface Features -- cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure. START / END PROGRAMMING BAR CODES Disable Transmission Error Indication Enable Transmission Error Indication DEFAULT IBM-USB Interface Features IBM-USB Device usage The IBM-USB protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are: · · Table Top Scanner Handheld Scanner START / END PROGRAMMING BAR CODES Configure as Table Top Scanner Configure as Handheld Scanner DEFAULT 3-24 Magellan® 1400i Interface Features IBM IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for IBM USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B. START / END PROGRAMMING BAR CODES Disable Convert to Code 39 DEFAULT Enable Convert to Code 39 Product Reference Guide 3-25 Interface Related Features Wand Emulation Supported Symbologies The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code symbologies: · · · · · · · UPC/EAN UPC/EAN with addons Code 39 Full ASCII Code 39 Interleaved 2 of 5 Codabar Code 128 Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scanner will be transmitted as Code 128. Wand Emulation Bar Code Format The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners. · · · · · · · UPC-A bar codes must include all 12 digits. UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the check digit. Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start / stop characters. Codabar bar codes must include the start / stop characters, presented in the ABCD format. Interleaved 2 of 5 bar codes must have an even number of digits. 3-26 Magellan® 1400i Interface Features Wand Emulation -- cont. Bar/Space Polarity Low/High -- Black will be transmitted as a low voltage level (0 to +0. 7V) and space as high level (+2. 4 to +5. 25V). High/Low -- Black will be transmitted as a high voltage level (+2. 4 to +5. 25V) and space as low level (0 to +0. 7V). START / END PROGRAMMING BAR CODES Bar/Space = Low/High Bar/Space = High/Low DEFAULT Wand Idle State This feature specifies the level of the wand output signal when idle. TTL logic levels: High voltage level (+2. 4 to +5. 25V) Low voltage level (0 to +0. 7V). START / END PROGRAMMING BAR CODES Wand Idle State = Low DEFAULT Wand Idle State = High Product Reference Guide 3-27 Interface Related Features Wand Emulation -- cont. Signal Speed The speed of the transmission can be set. 330 microseconds 660 microseconds START / END PROGRAMMING BAR CODES Signal Speed = 330mS Signal Speed = 660mS DEFAULT Transmit Trailing Noise The transmission of noise pulses after the label may be enabled or disabled. START / END PROGRAMMING BAR CODES Disable Trailing Noise Enable Trailing Noise DEFAULT 3-28 Magellan® 1400i Interface Features Wand Emulation -- cont. Transmit Leading Noise The transmission of noise pulses before the bar code may be enabled or disabled. START / END PROGRAMMING BAR CODES Disable Leading Noise Enable Leading Noise DEFAULT Symbology Conversion Wand Emulation can convert all bar codes to a single symbology. Choices are: No Conversion Convert to Code 39 Convert to Code 128 START / END PROGRAMMING BAR CODES No Symbology Conversion DEFAULT Convert to C39 Convert to C128 Product Reference Guide 3-29 Interface Related Features Keyboard Wedge and USB Keyboard As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn't require any changes of software or hardware. All of the options in this section apply to the Keyboard Wedge, however, only some apply to USB Keyboard. NOTE Keyboard Layout The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual. START / END PROGRAMMING BAR CODES USA DEFAULT Belgium Britain Denmark France Germany 3-30 Magellan® 1400i Interface Features Keyboard Wedge -- cont. START / END PROGRAMMING BAR CODES Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech Product Reference Guide 3-31 Interface Related Features Keyboard Wedge -- cont. START / END PROGRAMMING BAR CODES Slovakia Romania Croatia Poland Caps Lock State Specifies the format in which the scanner sends character data. START / END PROGRAMMING BAR CODES Disable Caps Lock DEFAULT Caps Lock "ON" Shift Lock "ON" 3-32 Magellan® 1400i Interface Features Keyboard Wedge -- cont. Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on. START / END PROGRAMMING BAR CODES Disable Power-on Simulation DEFAULT ³ Enable Power-on Simulation ³ 028901 Product Reference Guide 3-33 Interface Related Features Keyboard Wedge -- cont. Control Characters Specifies how the scanner transmits ASCII control characters to the host. [. . . ] RS-232 Setting 1 Disable Don't Transmit Enable Interface-Specific Exceptions Page # 5-32 5-33 5-33 5-34 Enable 5-35 Disable Don't Transmit Variable Length 1 80 Disable Disable 1 Disable Disable Enable Variable Length 6 50 Disable 1 5-35 5-36 5-37 5-38 5-38 5-38 5-39 5-39 5-40 5-40 5-47 5-42 5-43 5-43 5-44 5-45 D-8 Magellan® 1400i Standard Feature Defaults Feature Disable/Enable Codabar Codabar Check Character Verification Codabar Check Character Transmit Codabar Length Control Codabar Length 1 Codabar Length 2 Codabar Quiet Zones Codabar Start/Stop Character Type Codabar Start/Stop Character Transmission Codabar Start/Stop Character Match Codabar Stitching Codabar Minimum Reads Disable/Enable Code 93 Code 93 Length Control Code 93 Length 1 Code 93 Length 2 Code 93 Stitching Code 93 Minimum Reads Disable/Enable MSI/ Plessey MSI/Plessey Check Digit Verification MSI/Plessey Check Digit Transmit Std. RS-232 Setting Disable Disable Enable Variable Length 3 50 Don't Require Start/Stop Type: abcd/ abcd Enable Interface-Specific Exceptions Page # 5-46 5-46 5-47 5-48 5-49 5-49 5-49 5-50 5-50 Disable Disable 1 Disable Variable Length 1 50 Disable 1 Disable Disable 1-Digit 5-51 5-51 5-52 5-53 5-54 5-55 5-55 5-56 5-56 5-57 5-57 5-58 Product Reference Guide D-9 Feature Number of Check Characters MSI/Plessey Length Control MSI/Plessey Length 1 MSI/Plessey Length 2 MSI/Plessey Stitching MSI/Plessey Minimum Reads Disable/Enable Standard 2 of 5 Std 2 of 5 Check Digit Verification Std 2 of 5 Check Digit Transmit Std 2 of 5 Length Control Std 2 of 5 Length 1 Std 2 of 5 Length 2 Standard 2 of 5 Stitching Std 2 of 5 Minimum Reads Disable/Enable PDF417 PDF417 Length Control PDF417 Length 1 PDF417 Length 2 PDF417 Minimum Reads Std. RS-232 Setting 1 Check Character Variable Length 4 16 Disable 1 Disable Disable Enable Variable Length 8 50 Disable 1 Disable Variable Length 1 600 1 Interface-Specific Exceptions Page # 5-58 5-65 5-60 5-60 5-61 5-62 5-63 5-63 5-64 5-65 5-66 5-66 5-67 5-68 5-69 5-70 5-71 5-71 5-69 D-10 Magellan® 1400i Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 1400I




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 1400I will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.