User manual DATALOGIC MAGELLAN 8100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 8100. We hope that this DATALOGIC MAGELLAN 8100 user guide will be useful to you.


DATALOGIC MAGELLAN 8100 : Download the complete user guide (4567 Ko)

Manual abstract: user guide DATALOGIC MAGELLAN 8100

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 8100/8100 8200/8200 Model 8204 shown Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. [. . . ] Complete the programming sequence by scanning the SWITCH bar code. RS-232 ACK NAK ERROR HANDLING = IGNORE ERRORS Product Reference Guide 6-95 RS-232 ACK NAK Error Handling -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. RS-232 ACK NAK ERROR HANDLING = ASSUME ACK RS-232 ACK NAK ERROR HANDLING = ASSUME NAK 6-96 Magellan® 8100/8100 and 8200/8200 Scanner RS-232 Label ID Control This feature specifies whether or not Label IDs are transmitted to the host and if so, whether to attach them as a prefix or suffix. RS-232 LABEL ID CONTROL = DISABLE RS-232 LABEL ID CONTROL = ENABLE AS PREFIX Product Reference Guide 6-97 RS-232 Label ID Control -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. RS-232 LABEL ID CONTROL = ENABLE AS SUFFIX 6-98 Magellan® 8100/8100 and 8200/8200 Scanner Single Cable RS-232 Options The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces. Rather than repeat them in this section as Single Cable options, please find them referenced as follows: · · · · · · · · RS-232 Baud Rate on page 68 RS-232 Number of Data Bits on page 72 RS-232 Number of Stop Bits on page 73 RS-232 Parity on page 74 RS-232 Software Flow Control on page 79 RS-232 Beep After Weigh on page 86 RS-232 Beep on Not on File on page 87 RS-232 Label ID Control on page 97 Product Reference Guide 6-99 Single Cable RS-232 Scanner Only Protocol This sets the type of interface protocol that will be used in Single Cable RS-232. Options are: · · Scanner/scale RS-232 protocol Scanner only RS-232 protocol To set this feature: 1. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SINGLE CABLE RS-232 PROTOCOL = SCANNER/SCALE SINGLE CABLE RS-232 PROTOCOL = SCANNER ONLY 6-100 Magellan® 8100/8100 and 8200/8200 Scanner Single Cable RS-232 RTS CTS Selection Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the configuration values state, to determine when to send label data. Choices are: · · · · · · Option 0 = RTS is held in low state and CTS is ignored Option 1 = RTS is held in high state and CTS is ignored Option 2 = Assert RTS and wait for CTS to be asserted Option 3 = Assert RTS and ignore CTS Option 4 = RTS held low, wait for CTS to be asserted Option 5 = RTS held high, wait for CTS to be asserted To set this feature: 1. Scan a bar code below or on the following pages representing the desired option. You'll need to cover any unused bar codes, as well as facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. RTS CTS SELECTION = OPTION 0 RTS CTS SELECTION = OPTION 1 Product Reference Guide 6-101 Single Cable RS-232 RTS CTS Selection -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. RTS CTS SELECTION = OPTION 2 RTS CTS SELECTION = OPTION 3 6-102 Magellan® 8100/8100 and 8200/8200 Scanner Single Cable RS-232 RTS CTS Selection -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. RTS CTS SELECTION = OPTION 4 RTS CTS SELECTION = OPTION 5 Product Reference Guide 6-103 Single Cable RS-232 Use BCC Enables/disables the ability of the scanner to use BCC. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SINGLE CABLE RS-232 USE BCC = DISABLE SINGLE CABLE RS-232 USE BCC = ENABLE Magellan® 8100/8100 and 8200/8200 Scanner 6-104 Single Cable RS-232 Use ACK/NAK Enables/disables the ability of the scanner to use ACK/NAK. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SINGLE CABLE RS-232 USE ACK/NAK = DISABLE SINGLE CABLE RS-232 USE ACK/NAK = ENABLE Product Reference Guide 6-105 Single Cable RS-232 Use STX Enables/disables the ability of the scanner to use STX. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SINGLE CABLE RS-232 USE STX = DISABLE SINGLE CABLE RS-232 USE STX = ENABLE Magellan® 8100/8100 and 8200/8200 Scanner 6-106 Set Single Cable RS-232 STX Character This feature selects the STX character. You'll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual. ASCII parameters must be input by scanning decimal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). [. . . ] F-10 UPC-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-122 UPC-E Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-120 UPC-E Label ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-121 UPC-E with 2-Digit Supplemental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 8100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 8100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.