User manual DATALOGIC MAGELLAN 8300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 8300. We hope that this DATALOGIC MAGELLAN 8300 user guide will be useful to you.


DATALOGIC MAGELLAN 8300 : Download the complete user guide (3324 Ko)

Manual abstract: user guide DATALOGIC MAGELLAN 8300

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 8300/8400 Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] Scanning the TEST MODE = DISABLE bar code sets the Double Read Timeout to 600ms. NOTE TEST MODE = DISABLE TEST MODE = ENABLE Product Reference Guide 6-11 General Scanner Features Scanner Button Options Allows configuration of the scanner (volume) button to different modes of operation. · · · Disable Scanner Button -- Disables all button functions Enable Standard Functions -- Enables volume, tone, and reset. Enable Reset Only -- The button's sole function will be to reset the scanner. To set this feature: 1. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SCANNER BUTTON OPTIONS = DISABLE SCANNER BUTTON 6-12 Magellan® 8300/8400 General Scanner Features Scanner Button Options -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. SCANNER BUTTON OPTIONS = ENABLE STANDARD FUNCTIONS SCANNER BUTTON OPTIONS = ENABLE RESET ONLY Product Reference Guide 6-13 Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e. g. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. If the incidence of multiple reads is not acceptable, increase the Double Read Timeout setting to a higher value. NOTE DOUBLE READ TIMEOUT = 400ms DOUBLE READ TIMEOUT = 600ms 6-14 Magellan® 8300/8400 General Scanner Features Double Read Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. DOUBLE READ TIMEOUT = 800ms DOUBLE READ TIMEOUT = 1 SECOND Product Reference Guide 6-15 Laser Timeout The laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. LASER TIMEOUT = 5 MINUTES 6-16 Magellan® 8300/8400 General Scanner Features Laser Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. LASER TIMEOUT = 10 MINUTES LASER TIMEOUT = 15 MINUTES Product Reference Guide 6-17 Motor Timeout The Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use. Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the motor and the laser will both shut off when the motor timeout expires. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. MOTOR TIMEOUT = 5 MINUTES 6-18 Magellan® 8300/8400 General Scanner Features Motor Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. MOTOR TIMEOUT = 10 MINUTES MOTOR TIMEOUT = 15 MINUTES Product Reference Guide 6-19 Motor Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. MOTOR TIMEOUT = 30 MINUTES MOTOR TIMEOUT = 60 MINUTES 6-20 Magellan® 8300/8400 General Scanner Features Label Gone Timeout Specifies the amount of time that data segments are stored by the software before being discarded if a label has not been successfully decoded during the current "label in volume session, " which is defined as the time between when the label gone time is first started until the label gone timer expires. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. LABEL GONE TIMEOUT = 50 mS Product Reference Guide 6-21 Label Gone Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. LABEL GONE TIMEOUT = 160 mS LABEL GONE TIMEOUT = 250 mS 6-22 Magellan® 8300/8400 General Scanner Features Label Gone Timeout -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. LABEL GONE TIMEOUT = 500 mS LABEL GONE TIMEOUT = 1 Second Product Reference Guide 6-23 Auxiliary Port Mode Selects the usage for the scanner's optional auxilliary port. The choices listed below are mutually exclusive (only one option can be active at a time). · · Disabled -- Port is inactive External Handheld Input -- Supports Datalogic® handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices. Cable pinout information for the Auxiliary Port is provided in Appendix B of this manual. A connected handheld scanner must be configured to transmit data as outlined in Appendix G. NOTE · PIR/CT -- PIR (Productivity Index Reporting) is a value-added feature which allows the scanner to provide information to an external computer indicating how easy the label was to read. CT (Checker Training) is also a value-added feature which allows the scanner to provide feedback to the cashier on how to scan in a more ergonomic fashion To set this feature: 1. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. [. . . ] Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. Example : ']G0Code93-test'. · DataBar Omnidirectional · · · · Prefix must be ASCII characters ']e0'. Example: ']e001044123456789'. DataBar Expanded · · Prefix must be ASCII characters ']e0'. Label length excluding prefix characters must be at least 1 character. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 8300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 8300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.