User manual DATALOGIC MAGELLAN 8500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC MAGELLAN 8500. We hope that this DATALOGIC MAGELLAN 8500 user guide will be useful to you.


DATALOGIC MAGELLAN 8500 : Download the complete user guide (4017 Ko)

Manual abstract: user guide DATALOGIC MAGELLAN 8500

Detailed instructions for use are in the User's Guide.

[. . . ] Magellan® 8500/8500 Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. [. . . ] Choices are: · · · No Scale Interface RS-232 -- SASI RS-232 -- ICL To set the Scale Interface Type: 1. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SCALE INTERFACE TYPE = NO SCALE INTERFACE SCALE INTERFACE TYPE = RS-232 -- SASI 6-38 Magellan® 8500 Scanner Scale Interface Type -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. SCALE INTERFACE TYPE = RS-232 -- ICL Product Reference Guide 6-39 Scale Motion Level Filter In environments where checkstands generate excessive vibration, the scale can be set to filter a certain amount of the motion with regard to its operation. This filter is generally used only in applications where scale error E_1 (too much motion at power-up) has occurred. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. The strategy is to select the lowest possible filter level needed that allows normal scale operation. Complete the programming sequence by scanning the SWITCH bar code. SCALE MOTION LEVEL FILTER = LOW SCALE MOTION LEVEL FILTER = MEDIUM LOW 6-40 Magellan® 8500 Scanner Scale Motion Level Filter -- continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. SCALE MOTION LEVEL FILTER = MEDIUM HIGH SCALE MOTION LEVEL FILTER = HIGH Product Reference Guide 6-41 Scale LED Enable This feature enables/disables Scale LED (Yellow LED) operation. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. SCALE LED = DISABLE SCALE LED = ENABLE 6-42 Magellan® 8500 Scanner Remote Display -- Enable/Disable The scanner-scale can be configured to operate with or without a Remote Display. Recalibration/recertification may be required when adding a Remote Display. If this feature is enabled the scanner-scale will expect that it is connected to a Remote Display, and will indicate an error if one is not. See Error Codes in Section 4 for more information. NOTE REMOTE DISPLAY = DISABLE REMOTE DISPLAY = ENABLE Product Reference Guide 6-43 EAS Active State Specifies the active state polarity of EAS (Electronic Article Survellance); the inactive state is its opposite polarity. EAS output goes active during the good read of a bar code, allowing the EAS device to deactivate a tag on the product. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code. EAS ACTIVE STATE = ACTIVE LOW EAS ACTIVE STATE = ACTIVE HIGH 6-44 Magellan® 8500 Scanner EAS Timeout Specifies the amount of time that an EAS (Electronic Article Survellance) signal is held in its active state for a good read. You'll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Scan the appropriate digits from the keypad in Appendix C that represent the desired EAS Timeout duration. The selectable range is 0-255, which is the timeout in 10-millisecond increments. Pad all single and double digit numbers with leading zeroes to yield a three-digit entry (000-255). Examples: 000 = EAS timeout disabled 001 = 10ms 005 = 50ms 040 = 400ms 250 = 2, 500ms (2. 5 seconds) A setting of 0 (000) disables this feature. The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned SET EAS TIMEOUT Product Reference Guide 6-45 Aux Port Mode Selects the usage for the scanner's optional auxiliary port. The choices listed below are mutually exclusive (only one option can be active at a time). · · Disabled -- Port is inactive External Handheld Input -- Supports DatalogicTM handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices. Cable pinout information for the Aux Port is provided in Appendix B of this manual. [. . . ] Example: ']M0144769254'. · · Code 93 · · Prefix must be ASCII characters ']G0'. Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. Example : ']G0Code93-test'. · RSS-14 · · · · Prefix must be ASCII characters ']e0'. Example: ']e001044123456789'. Product Reference Guide F-13 RSS Expanded · · Prefix must be ASCII characters ']e0'. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC MAGELLAN 8500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC MAGELLAN 8500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.