User manual DATALOGIC POWERSCAN PD7100 CORDED

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DATALOGIC POWERSCAN PD7100 CORDED. We hope that this DATALOGIC POWERSCAN PD7100 CORDED user guide will be useful to you.


DATALOGIC POWERSCAN PD7100 CORDED : Download the complete user guide (1257 Ko)

Manual abstract: user guide DATALOGIC POWERSCAN PD7100 CORDED

Detailed instructions for use are in the User's Guide.

[. . . ] PowerScan PD7100 Corded Linear Imaging Barcode Reader Product Reference Guide Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). [. . . ] Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. ACK Character Setting Examples STEP 1 2 3 4 5 6 ACTION Desired Character/Value Hex equivalent ACK 0x06 $ 0x24 EXAMPLES @ 0x40 > 0x3E Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK CHARACTER SETTING Scan Two Characters From Appendix E, Keypad `0' and `6' `2' and `4' `4' and `0' `3' AND `E' Scan ENTER/EXIT PROGRAMMING MODE 58 PowerScan PD7100 Corded ACK NAK Options ACK Character -- cont. ENTER/EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 `ACK' Character Product Reference Guide 59 RS-232/USB-Com Interfaces NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. NOTE To set this feature: 1. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. NAK Character Setting Examples STEP 1 2 3 4 5 6 ACTION Desired Character/Value Hex equivalent NAK 0x15 $ 0x24 EXAMPLES @ 0x40 > 0x3E Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK CHARACTER SETTING Scan Two Characters From Appendix E, Keypad `1' and `5' `2' and `4' `4' and `0' `3' AND `E' Scan ENTER/EXIT PROGRAMMING MODE 60 PowerScan PD7100 Corded ACK NAK Options NAK Character -- cont. ENTER/EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 `NAK' Character Product Reference Guide 61 RS-232/USB-Com Interfaces ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15, 000ms (15 seconds) in 200ms increments. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a twobeep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. ACK NAK Timeout Value Setting Examples STEP 1 2 3 4 5 7 ACTION Desired Setting Divide by 200 Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK NAK TIMEOUT VALUE SETTING Scan Two Characters From 200ms 01 EXAMPLES 1, 000ms (1 sec. ) 5200ms (5. 2 sec. ) 05 26 15, 000ms (1 sec. ) 75 Appendix E, Keypad `0' and `1' `0' and `5' `2' and `6' `7' and `5' Scan ENTER/EXIT PROGRAMMING MODE 62 PowerScan PD7100 Corded ACK NAK Options ACK NAK Timeout Value -- cont. ENTER/EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake?CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms Product Reference Guide 63 RS-232/USB-Com Interfaces ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. [. . . ] ^ TM t u v w x y d e f g h i j z S s T U V W X Y Z [ k { < > oe D E F G H I J K 3 4 5 6 7 8 9 : ; < L \ l | # $ % & ` ( ) * + , - Pg Dwn Home F9 F10 2x Space ! . O _ o Del _ Y 3x 0 1 4x @ A B 5x b r ` ' P Q R 6x ` a 7x p q 8x _ _ 9x _ ` Ax NBSP Bx Cx Dx _ Ex Fx Product Reference Guide 301 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode x3 Alt+003 Alt+019 Alt+020 Alt+021 Alt+022 Alt+023 Alt+024 Alt+025 Alt+026 ESC Esc Alt+028 Alt+029 Alt+004 Alt+005 Alt+006 Alt+007 Alt+008 HT TAB Alt+010 Alt+011 Alt+012 CR Enter Alt+014 Alt+030 Table 41. Scancode Set When Control Character is 00 or 01 x0 x1 x2 x4 x5 X6 x7 x8 x9 xA xB xC xD xE Xf Alt+015 Alt+031 0x Alt+000 Alt+001 Alt+002 1x A+035 A+051 A+067 A+083 A+099 A+115 Ins Ent (keyp) Pg Dwn A+0164 A+0180 A+0196 A+0212 A+0228 A+0244 A+0245 A+0229 A+0213 A+0214 A+0230 A+0246 A+0197 A+0198 A+0181 A+0182 A+0183 A+0199 A+0215 A+0231 A+0247 A+0165 A+0166 A+0167 A+0168 A+0184 A+0200 A+0216 A+0232 A+0248 Ar A+0169 A+0185 A+0201 A+0217 A+0233 A+0249 F1 F2 F3 F4 F5 A+116 A+117 A+118 A+119 A+120 A+121 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+122 F6 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+091 A+107 A+123 F7 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+060 A+076 A+092 A+108 A+124 F8 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 A+044 Alt+016 Alt+017 Alt+018 2x A+032 A+033 A+034 A+045 A+061 A+077 A+093 A+109 A+125 F9 A+046 A+062 A+078 A+094 A+110 A+126 F10 A+047 A+063 A+079 A+095 A+111 A+127 F11 3x A+048 A+049 A+050 4x A+064 A+065 A+066 5x A+080 A+081 A+082 6x A+096 A+097 A+098 7x A+112 A+113 A+114 8x Pg Up A+0163 A+0179 A+0195 A+0211 A+0227 A+0243 _ Sh Sh? 9x F12 Home End Ar A+0170 A+0186 A+0202 A+0218 A+0234 A+0250 Al A+0171 A+0187 A+0203 A+0219 A+0235 A+0251 Al A+0172 A+0188 A+0204 A+0220 A+0236 A+052 Cl A+0173 A+0189 A+0205 A+0221 A+0237 A+0253 Cl A+0174 A+0190 A+0206 A+0222 A+0238 A+0254 Cr A+0175 A+0191 A+0207 A+0223 A+0239 A+0255 Ax Cr A+0161 A+0162 Bx A+0176 A+0177 A+0178 Cx A+0192 A+0193 A+0194 Dx A+0208 A+0209 A+0210 Ex A+0224 A+0225 A+0226 Fx A+0240 A+0241 A+0242 Product Reference Guide 302 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode -- cont. x3 Al Cl Cr Cl Cr BS Tab S+ Tab Enter Keypd F7 A+044 A+060 A+076 A+092 A+107 A+123 A+0138 A+0154 A+0169 A+0184 A+0200 A+0215 A+0231 A+0246 A+0247 A+0216 A+0232 A+0248 A+0185 A+0201 A+0217 A+0233 A+0249 A+0170 A+0186 A+0202 A+0218 A+0234 A+0250 A+0139 A+0155 A+0171 A+0187 A+0203 A+0219 A+0235 A+0251 A+108 A+124 A+0140 A+0156 A+0172 A+0188 A+0204 A+0220 A+0236 A+052 Table 42. Scancode Set When Control Character is 02 x0 Enter Ins x1 x2 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF Pg Up 0x F6 A+035 A+051 A+067 A+083 A+099 A+115 A+0131 A+0147 A+0163 A+0179 A+0195 A+0211 A+0227 A+0243 A+0244 A+0245 A+0228 A+0229 A+0212 A+0213 A+0214 A+0230 A+0196 A+0197 A+0198 A+0180 A+0181 A+0182 A+0183 A+0199 A+0164 A+0165 A+0166 A+0167 A+0168 A+0148 A+0149 A+0150 A+0151 A+0152 A+0132 A+0133 A+0134 A+0135 A+0136 A+0137 A+0153 A+116 A+117 A+118 A+119 A+120 A+121 A+100 A+101 A+102 A+103 A+104 A+105 A+106 A+122 A+084 A+085 A+086 A+087 A+088 A+089 A+090 A+068 A+069 A+070 A+071 A+072 A+073 A+074 A+075 A+091 A+052 A+053 A+054 A+055 A+056 A+057 A+058 A+059 A+036 A+037 A+038 A+039 A+040 A+041 A+042 A+043 Ar Ar Al 1x F1 F2 F3 F4 F5 ESC F8 Pg Dwn Home F9 A+046 F10 A+047 2x A+032 A+033 A+034 A+045 A+061 A+077 A+093 A+109 A+125 A+0141 A+0157 A+0173 A+0189 A+0205 A+0221 A+0237 A+0253 3x A+048 A+049 A+050 A+062 A+078 A+094 A+110 A+126 A+0142 A+0158 A+0174 A+0190 A+0206 A+0222 A+0238 A+0254 A+063 A+079 A+095 A+111 A+127 A+0143 A+0159 A+0175 A+0191 A+0207 A+0223 A+0239 A+0255 4x A+064 A+065 A+066 5x A+080 A+081 A+082 6x A+096 A+097 A+098 7x A+112 A+113 A+114 8x A+0128 A+0129 A+0130 9x A+0144 A+0145 A+0146 Ax A+0160 A+0161 A+0162 Bx A+0176 A+0177 A+0178 Cx A+0192 A+0193 A+0194 Dx A+0208 A+0209 A+0210 Ex A+0224 A+0225 A+0226 Fx A+0240 A+0241 A+0242 Product Reference Guide 303 Digital Interface x3 ETX C(S)+C DC3 C(S)+S DC4 C(S)+T NAK C(S)+U SYN C(S)+V ETB C(S)+W CAN C(S)+X EM C(S)+Y SUB C(S)+Z ESC Esc FS C(S)+\ GS C+] EOT C+D ENQ C(S)+E ACK C(S)+F BEL C(S)+G BS C(S)+H HT TAB LF C(S)+J VT C(S)+K FF C(S)+L CR Enter SO C(S)+N RS C(S)+^ Table 43. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC POWERSCAN PD7100 CORDED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC POWERSCAN PD7100 CORDED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.