User manual DAXTEN RACKACCESS 8I

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAXTEN RACKACCESS 8I. We hope that this DAXTEN RACKACCESS 8I user guide will be useful to you.


DAXTEN RACKACCESS 8I : Download the complete user guide (643 Ko)

You may also download the following manuals related to this product:

   DAXTEN RACKACCESS 8I (445 ko)
   DAXTEN RACKACCESS 8I BROCHURE (330 ko)
   DAXTEN RACKACCESS 8I BROCHURE (446 ko)
   DAXTEN RACKACCESS 8I BROCHURE (661 ko)
   DAXTEN RACKACCESS 8I BROCHURE (140 ko)

Manual abstract: user guide DAXTEN RACKACCESS 8I

Detailed instructions for use are in the User's Guide.

[. . . ] RackAccess 8i RackAccess 16i Installation guide Specifications Part Numbers 3115-108M-xx 3115-116M-xx 3115-116MIP-xx 3117-108M-xx 3117-116M-xx 3117-116MIP-xx 3119-108M-xx 3119-116M-xx 3119-116MIP-xx RackAccess 8i console 15" TFT Display & integrated SCOUTutp 8 port kvm Switch RackAccess 16i console 15" TFT Display & integrated SCOUTutp 16 port kvm Switch RackAccess 16i console 15" TFT Display & integrated SCOUTutp 16 port kvm Switch & IP Access RackAccess 8i console 17" TFT Display & integrated SCOUTutp 8 port kvm Switch RackAccess 16i console 17" TFT Display & integrated SCOUTutp 16 port kvm Switch RackAccess 16i console 17" TFT Display & integrated SCOUTutp 16 port kvm Switch & IP Access RackAccess 8i console 19" TFT Display & integrated SCOUTutp 8 port kvm Switch RackAccess 16i console 19" TFT Display & integrated SCOUTutp 16 port kvm Switch RackAccess 16i console 19" TFT Display & integrated SCOUTutp 16 port kvm Switch & IP Access xx represents country specific keyboard layouts Part Numbers 2364-01P 2364-01U 2364-01S 2364-00A SCOUTutp CPU Adaptor PS/2 SCOUTutp CPU Adaptor USB SCOUTutp CPU Adaptor SUN SCOUTutp Flash upgrade Cable Height 4. 32cm / 1. 7" 4. 32cm / 1. 7" 4. 32cm / 1. 7" Width 48. 26cm / 19" 48. 26cm / 19" 48. 26cm / 19" Depth 51. 51cm / 20. 28" 56. 59cm / 22. 28" 56. 59cm / 22. 28" Weight 13kg / 28. 6lb 15kg / 33. 0lb 15kg / 33. 0lb Physical Properties RackAccess 15" TFT Display RackAccess 17" TFT Display RackAccess 19" TFT Display Operation and Storage parameters Operating Temperature: Humidity: Storage Temperature: Humidity: 15" TFT Display 0 ~ 40° C 32 ~104° F 10~85% RH noncondensing -20 ~ 60° C - 4 ~140° F 10~95% RH noncondensing 17" TFT Display 0 ~ 40°C 32 ~104° F 10~85% RH noncondensing -20 ~ 60° C - 4 ~140° F 10~95% RH noncondensing 19" TFT Display 0 ~ 40°C 32 ~104° F 10~85% RH noncondensing -20 ~ 60° C - 4 ~140° F 10~95% RH noncondensing Connections PC: Upgrade Power All in one RJ45 Socket (Keyboard, Video and Mouse) RJ11 Socket IEC Female connector RackAccess i Series 1 User Guide Monitor Display Area: Scan frequency horizontal: Scan frequency vertical: Viewing Angle: Pixels: Pixel pitch: Picture tube: Video: Sync: Display Data Channel Compatibility 15" TFT Display 30. 4 x 22. 8 cm 12 x 9" 31. 47K to 68KHz 60Hz to 85Hz 160° Horizontal, 160° Vertical 1024 x 768 0. 297 x 0. 297 mm 15" TFT Active Matrix Analog RGB 7Vp-p/75 Separate DDC 2B 17" TFT Display 33. 7 x 27. 0 cm 13. 7 x 10. 64" 31. 47K to 68KHz 60Hz to 75Hz 140° Horizontal, 110° Vertical 1280 x 1024 0. 264 x 0. 264 mm 17" TFT Active Matrix Analog RGB 0. 7 Vp-p/75 Separate DDC 2B 19" TFT Display 37. 6 x 30. 10 cm 14. 8 x 11. 8" 31. 47K to 68KHz 60Hz to 75Hz 140° Horizontal, 135° Vertical 1280 x 1024 0. 294 x 0. 294 mm 19" TFT Active Matrix Analog RGB 0. 7 Vp-p/75 Separate DDC 2B Keyboard Keys Travel Typing force Life cycle 88 key keyboard & 17 key numeric keypad 3mm / 0. 11" 60g ± 20g / 2. 11oz ± 0. 70oz 10 million key presses Touchpad Compatibility Mouse button Life cycle Industrial standard Two key buttons >1 million cycles Operations User Controls: On Screen Display Adjustment Control type Operating Systems Transmission distance On/Off Power Button Contrast, Brightness, Display Quality, OSD adjustment Auto-Adjustment Contrast, Balance Phase, Pixel clock TXT/GFX Selection Colour temperature & brightness Digital DOS, Windows (9X, NT4, 2000, XP, 2003 Server) LINUX, UNIX, QNX, SGI, FreeBSD, BeOS, Open VMS, Novell, Alpha UNIX, HP UX, SUN Up to 10m (33ft) Power Input Consumption 110-240 VAC (auto sensing) 48-62Hz 35 Watts maximum (On) on 15" RackAccess 45 Watts maximum (On) on 17" RackAccess 50 Watts maximum (On) on 19" RackAccess 1 Watt Power Saving Mode (Off) RackAccess i Series 2 User Guide Agency Approvals EMI Emissions Energy Saving FCC-A and CE MRP-II EPA energy star, VESA DPMS CPU Adaptors Connections Video Keyboard/Mouse System Power Product weight Shipping weight Dimensions PS/2 HD15 MiniDin6 RJ45 From computer's Keyboard port USB HD15 USB RJ45 From USB port 107g / 0. 23lb 300g / 0. 66lb SUN HD15 MiniDin8 RJ45 From computer's Keyboard port 91 x 41 x 24mm / 3. 58 x 1. 61 x 0. 94" NOTE: This equipment complies with the requirements of European EMC directive 89/336 EEC in respect of EN55022 Class B, EN 50082-1 and EN 60555-2. This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. [. . . ] Press Esc to save and exit. Using the Control software As an alternative to the OSD you can operate the SCOUTutp system with the Control software located on the Documentation CD. With the OSD you operate the system and view the computer screens on the same monitor. The Control software requires 2 monitors 1 for the software and 1 to view the computer screens. With the Control software you can: -View computers -Edit OSD Settings -Save configurations for future use -Read and write configurations to the SCOUTutp Switch Control software system requirements Pentium 166 or higher computer, 16Mb RAM, Windows 98 and later, a free Serial port Connecting the serial download cable To run the software, connect the serial cable to the computer containing the software, and to the SCOUTutp. The system must be fully connected BEFORE running the Control software. Failure to connect the system first will lead to the software working in demo mode. To run the software from the CD: Choose Run SCOUTutp switch Control Software from CD. If the Security feature is activated, the software requires a password. Selecting a Com port (Serial port) During the Setup process you will be prompted to choose a Com port. Failure to select the correct Com port will result in the software running in demo mode. Computer icons Icon Meaning Computer is connected and switched on Computer is switched off or unconnected Icon Meaning Computer that you are presently connected to Connected and switched on computer with a Local Workstation attached and presently being used locally. After remaining idle for the Timeout period, it changes to yellow. When you first open the Control window the software automatically gets the status of the system, including the security access Settings. RackAccess i Series 12 User Guide Communication Error If a Communication Error box appears when trying to scan the system, check that: The Serial download cable is connected to the computer's and SCOUTutp IP Manager's serial ports. The View menu From the View menu choose one of the following: -All computers, or only active switched on computers. -The Legend -The toolbar Selecting a computer To select a computer: Click on the computers icon. Control and monitor the selected computer from the keyboard and mouse connected to the SCOUTutp. The toolbar buttons The toolbar buttons are explained below. Get Status If for whatever reason there is a break in communication between the Control software and the system, click "Get Status" to get the current status of the computers in system. Read Configuration To see the current Settings of the entire system (names, scan Settings etc. ) click "Read Configuration". You view the computer Settings from the Control window and other Settings from the Edit menu ­ discussed below. Write Configuration With the Control software you can make changes to all OSD Settings. You can then save these configurations in a file to use in the future by selecting Save or Save As from the File menu. To change the OSD Settings you must press "Write Configuration" or choose Write Configuration from the File menu after making changes. The changes will then be sent to the SCOUTutp system Manager, and the OSD will reflect these changes. [. . . ] Scandinavian "*" key code conversion changes the scan code for the <|> (pipe character) key. Allows the operating system to control the "Num Lock" indicator. (Default mode uses <Scroll Lock> as a Mac "Power off" key). Esc Esc Esc Esc Esc O P Q T Y RackAccess i Series 18 User Guide Service Information Technical Support If you cannot determine the nature of a problem, please call Daxten and ask for Technical Support. If possible, call from a phone located near the unit, as we may be able to solve your problem directly over the phone. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAXTEN RACKACCESS 8I




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAXTEN RACKACCESS 8I will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.