User manual DRAKE DIGITAL DA8642

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DRAKE DIGITAL DA8642. We hope that this DRAKE DIGITAL DA8642 user guide will be useful to you.


DRAKE DIGITAL DA8642 : Download the complete user guide (253 Ko)

Manual abstract: user guide DRAKE DIGITAL DA8642

Detailed instructions for use are in the User's Guide.

[. . . ] Vertical mounting on a wall with the output end up is recommended for best ventilation and the coolest operation. OUT 4) If the power transformer is to be wall mounted, install the included bracket as shown. WALL MOUNTING HOLES OF MOUNTING BRACKET SCREW HOLES FOR WALL MOUNTING (2 each side) SCREWS FOR FASTENING MOUNTING BRACKET TO TRANSFORMER CASE 5) Connect input and output cables to the amplifier. 6) Plug the power transformer line cord into a 120 VAC/60 Hz power source. [. . . ] Choose an SXP type attenuator of the value required, and install at the location indicated below. Carefully replace the top cover being sure that the spacer mounted to the cover does not unseat the just installed attenuator. The spacer should be directly over the attenuator when the cover is positioned correctly. FORWARD PATH FIXED INPUT ATTENUATION LOCATION A factory installed jumper is installed here for no attenuation. To install an input attenuator, remove jumper and plug in a "SXP" type attenuator rated for the same or higher frequency as the amplifier. IN OUT IN OUT GROUND ATTENUATOR +18 dBmV +10 dBmV +16 dBmV +7 dBmV +12 dBmV + 7 dBmV GROUND +44 dBmV +44 dBmV +40 dBmV +40 dBmV +38 dBmV +38 dBmV 110 CH 110 CH 129 CH 129 CH 150 CH 150 CH INSTALLING AN INPUT EQUALIZER Follow the same basic procedure as described above for the input attenuator except that the equalizer is installed at the equalizer location shown above. NOTE ABOUT COVER REMOVAL AND REPLACEMENT This note only applies if the input attenuator has been installed. There is a spacer mounted to the inside of the top cover that will be located directly above the input attenuator. When removing or replacing the cover, be sure that all of the cover screws are loosened several turns before moving the cover. Be sure the attenuator is seated fully in its socket before reinstalling the cover, and carefully place the cover in position with the spacer directly over the attenuator, before retightening the screws. POWER LED FORWARD PATH INPUT EQUALIZER LOCATION A factory installed jumper is installed here for no equalization. If the equalizer is later removed, the jumper must be reconnected between the IN and OUT connections, keeping the length as short as possible. If the input level is within the optimum input level window, distortion will be at or below that which is specified. If a higher input level is supplied, add a fixed input attenuator equal to the number of dB needed to reduce the level to be within the optimum input range. 4 Specifications and Warranty SPECIFICATIONS COMMON TO ALL MODELS Forward Gain Adjustment Range: 10 dB minimum. Power Requirement: 26 VAC from supplied transformer with six foot amp-to-transformer cable. ADDITIONAL SPECIFICATIONS FOR SPECIFIC MODELS DA7533 Frequency Coverage (fwd path): 49 to 750 MHz. Output Level (maximum per channel for distortions listed below): +44 dBmV. Power Transformer: Supplied transformer has 120 VAC/ 60 Hz ±10% input requirement at 35 W. Output is 26. 3 VAC with screw terminals for attaching power cable from amplifier. Size: 10. 25" (26 cm) L x 7. 25" (18. 4 cm) W x 2. 75" (7 cm) D. - 64 dB. DA100032 DA100042 49 to 1000 MHz 32 dB 42 dB 8 dB maximum 7 dB max. 12 dB 12 dB 150 CH 150 CH +38dBmV +12 dBmV +6 dBmV to +10 dBmV -62 dB -60 dB -66 dB +38 dBmV +7 dBmV -2 dBmV to +5 dBmV -62 dB -60 dB -66 dB Output levels listed above are for all analog and flat channel loading. Output levels could be significantly higher when some channels are QAM , 6 dB below analog, and when slope is applied. THREE YEAR LIMITED WARRANTY R. L. DRAKE LLC warrants to the original purchaser this product shall be free from defects in material or workmanship for three (3) years from the date of original purchase. [. . . ] To reduce the reverse path gain by 17 dB, move the 16 dB programmable attenuator jumper to the IN position. Then adjust the REVERSE PATH GAIN adjustment counterclockwise to obtain the additional 1 dB of attenuation. EXAMPLE 2 Assume that an installation requires 15 dB of gain reduction in the reverse path amplifier to achieve a gain of 7 dB. The step attenuator can be programmed for 12 dB (setting the 8 dB and 4 dB jumpers both to `IN') or to 14 dB (setting the 8 dB, 4 dB, and 2 dB jumpers all to `IN') and then adjusting the variable REVERSE PATH GAIN control to reduce the gain the additional 1 or 3 dB. The idea here is that one should set the step attenuator slightly less than the attenuation needed so that there can always be some fine adjustment of the variable gain control. (Jumpers at the "4 db" and "8 dB" "IN" positions) (Jumpers at the "2 dB", "4 dB", and "8 dB" "IN" positions) SUMMARY If reverse input levels are low, in the 0 dBmV area, use as little attenuation at the reverse path gain input attenuator as possible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DRAKE DIGITAL DA8642




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DRAKE DIGITAL DA8642 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.