User manual DSC PC4000
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC4000. We hope that this DSC PC4000 user guide will be useful to you.
Manual abstract: user guide DSC PC4000
Detailed instructions for use are in the User's Guide.
[. . . ] Jan 11, 1993 Software Version 1. 3
INSTRUCTION MANUAL
PC4OOO SECURITY SYSTEM
DOC NOTICE
NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. [. . . ] Smoke Detector Loop Trouble. . . If a FIRE loop is open circuit, a keypad trouble and a Fire Loop trouble transmission are generated. A trouble on the FIRE loop will unconditionally initiate an audible indication on the keypad. This means that even if any other previous trouble has been silenced, a FIRE loop trouble will restart the keypad buzzer. Loss of Internal Time. . . When the PC4000 is powered up, the internal time of day clock needs to be set to the correct time. 4204 Battery TBL. . . If any PC4204 relay output module's battery drops below 11. 3 volts, a battery trouble is generated. So the battery trouble may not restore instantly when the battery voltage is restored. 4204 AC Trouble. . . If any PC4204 relay output module loses incoming AC power, the keypad trouble light will indicate a 4204 AC trouble. But there will be no audible annunciation until there is also a low battery condition. 4204 AUX Trouble. . . If the Aux fuse on any PC4204 relay module should open or if the Aux supply is overloaded, a 4204 Aux trouble is generated. 5
ALARM MEMORY DISPLAY
[]+[3] Press [] then [3] to enter the alarm memory mode. The "Alarm Memory" message will only be displayed when an alarm occurred during the last armed period. Press [#] to return to "READY".
USER FUNCTIONS COMMAND
[]+[6]+[ACCESS CODE] Enter [][6][Access Code] and then use the [<][>] keys to display the items of the function menu. [0] Quick Arm [1] Quick Exit [2] Auto Arm Control [3] Keypad Setup [4] Bell/Comm Test [5] Door Chime [6] Spec. Messages [7] User Call Up [8] View Partitions Item [0], [1], [5] and [6] turn on and off various functions. To enable or disable these functions, press the [] key to toggle "Y "or "N" on the keypad. Y - The function is enabled N - The function is disabled QUICK ARM []+[6]+[ACCESS CODE]+[0] The "Quick Arm" feature is enabled by toggling to "Y" on the keypad. One time use access codes should not be used with the quick arm feature. QUICK EXIT []+[6]+[ACCESS CODE]+[1] The "Quick Exit" function is enabled by toggling to "Y" on the keypad. When enabled the user can exit through any delay zone without altering the status of the system, by entering [][0] on the keypad. AUTO ARM CONTROL []+[6]+[ACCESS CODE]+[2] This function must be enabled by the installer, or an error tone will sound when this section is entered. The PC4000 can be programmed to arm a partition at the same time each day, by enabling the Auto Arm function and programming the Auto Arm time. The keypad begins to sound and the Bell/Siren will pulse once every 10 seconds to alert anyone on the premises that the system is about to arm. [. . . ] neither assumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. be liable for any direct or indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.
10
APPENDIX A
LIST OF AVAILABLE ASCII CHARACTERS
032
048
064
080
096
112
160
176
192
208
224
240
033
049
065
081
097
113
161
177
193
209
225
241
034
050
066
082
098
114
162
178
194
210
226
242
035
051
067
083
099
115
163
179
195
211
227
243
036
052
068
084
100
116
164
180
196
212
228
244
037
053
069
085
101
117
165
181
197
213
229
245
038
054
070
086
102
118
166
182
198
214
230
246
039
055
071
087
103
119
167
183
199
215
231
247
040
056
072
088
104
120
168
184
200
216
232
248
041
057
073
089
105
121
169
185
201
217
233
249
042
058
074
090
106
122
170
186
202
218
234
250
043
059
075
091
107
123
171
187
203
219
235
251
044
060
076
092
108
124
172
188
204
220
236
252
045
061
077
093
109
125
173
189
205
221
237
253
046
062
078
094
110
126
174
190
206
222
238
254
047
063
079
095
111
127
175
191
207
223
239
255
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC4000
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC4000 will begin.