User manual DSC PC5010 V1.0 REV3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC5010 V1.0. We hope that this DSC PC5010 V1.0 user guide will be useful to you.


DSC PC5010 V1.0 REV3: Download the complete user guide (1013 Ko)

Manual abstract: user guide DSC PC5010 V1.0REV3

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. Instruction Manual PC5O1O WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. [. . . ] To exit a function and return to the Ready state, press [#]; to select a function press [D]. NOTE: All functions can be performed from any LCD keypad by using the LED keypad commands, as well as by scrolling through the message display. Important Note: Test system weekly and have any system trouble conditions corrected by your alarm installer. LCD5501Z Keypad LCD5501Z Keypad: The LCD5501Z keypad shows the status of your security system using an LCD, along with fixed words and numbers. 10 Programming codes from an LCD Keypad: Master Code Press the [D] key to enter the function list. Access Codes Enter Master Access Code Enter your current Master Code. The display will read. . . (*) to Edit < > "01P" represents the first access code. Use the arrow (< >) keys to scroll to "40P" User Code 01P and press the [D] key to indicate that you wish to program the Master Code. The display will read. . . Enter New Code Enter the new Master Code. The Master Code must be four digits unless otherwise 1234 < > indicated by your installer. Once the new code is entered, the keypad will beep 3 times and the display will read. . . (*) to Edit < > Press [#] to exit the code programming function. User Code 01P Be sure to record your new Master Code on the "System Information" page in this booklet. NOTE: We recommend that the factory default Master Code [1234] not be used. Additional Access Codes To erase, add or change a user code, press [D] to enter the functions list. Use the arrow (< >) keys to scroll to the following message. . . Press (*) for<> Press [D]. Display will read. . . [*] to Edit <> Use the scroll keys (< >) to find the access code ­ indicated by "01P" to "34P" or User Code 01P "41P" to "42P" ­ you wish to add, change or delete. The display will read. . . Enter New Code To add or change a code, enter the new code. Access codes must be four digits 1234 < > unless otherwise indicated by your installer. Once the 4 digit code or [D] has been entered, the keypad sounder will beep 3 times and the display will read. . . [*] to Edit <> The "P" means the code has been programmed. Remember to record your new code(s) on the "System Information" page in this booklet. Access Code Attributes Additional programmable attributes, such as zone bypassing capability, can be activated or deactivated for each access code. For more information regarding access code attributes, please contact your installer. Partition Master Codes If your system is partitioned, you can have a master code for each partition. Partition 1 master code is access code 41, partition 2 master code is access code 42. 11 Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied before the next arming. [. . . ] EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment, please contact the facility indicated below for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning. 160 Washburn St. , Lockport, NY 14094 LIMITED WARRANTY Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC5010 V1.0




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC5010 V1.0 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.