User manual EFD ULTRASAVER
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EFD ULTRASAVER. We hope that this EFD ULTRASAVER user guide will be useful to you.
Manual abstract: user guide EFD ULTRASAVER
Detailed instructions for use are in the User's Guide.
[. . . ] ULTRASAVER USER GUIDE
TM
1200
·
1215
USA: 800-556-3484 In the UK: 0800 585733 In Mexico: 001-800-556-3484
®
A NORDSON COMPANY
Setting up the ULTRASAVERTM
Note: Clean, dry, filtered air is required to meet warranty. If necessary, use five-micron filter regulator (not supplied order #2000F755). [. . . ] Squeeze barrel sides slightly to allow trapped air to escape.
Caulking gun or spatula
Air gap
2/3 max. If drop forms at tip, turn vacuum control counter-clockwise until drop disappears.
5
2. To fill tip, set mode switch to steady (yellow light on) and press foot pedal. Set time at #3, adjust as necessary.
Note: Settings are general recommendations. For best results, test settings for your specific application.
How to make DOTS
GREEN
Time range adjustments special setups
Most applications work best with ULTRASAVER's default time setting (shipped with 0. 010 1. 000 momentary). However, for special setups the ULTRASAVER's time range may be adjusted with the rotary switch located under the plug in the bottom panel of the cabinet. To change the time range, rotate the switch to the desired setting using a small screwdriver. In maintained mode, the foot pedal must remain depressed throughout the entire dispense cycle. In momentary mode, the foot pedal can be pressed and immediately released, and the cycle will continue. If the pedal is pressed again during a cycle, the dispenser will stop.
Press the mode switch so the green light is lit. Press the foot pedal to repeat the same size dot.
MODE SWITCH
3
How to make STRIPES
YELLOW
Press the mode switch so the yellow light is lit. Place tip on work surface.
Switch Time range Setting in seconds 0 0. 005 0. 200 1 0. 010 1. 000 2 0. 050 10. 000 3 0. 100 20. 000 4 0. 015 30. 000 5 0. 005 0. 200 6 0. 010 1. 000 7 0. 050 10. 000 8 0. 100 20. 000 9 0. 015 30. 000
Foot pedal Mode Momentary Momentary Momentary Momentary Momentary Maintained Maintained Maintained Maintained Maintained
MODE SWITCH
Use the foot pedal to control flow.
Technical specifications
Input voltage: Fuse rating: Air input pressure: Air output pressure: Dimensions: Weight: 100-120/208-240 VAC, 50/60 Hz, 8VA max.
Exhaust
80 mA, 250V, Type T
40
50
3 2 4
R
60
80 100 psi (5. 5 6. 9 bar) Use only clean, dry, filtered air minimum 20 micron 1200: 0 100 psi (0 6. 9 bar) 1215: 0 15 psi (0 1. 03 bar) 4-3/4" w x 6" h x 5-1/2" d (120. 7mm x 152. 4mm x 139. 7mm) 2. 78 lbs. (1. 26 kg)
30
Dispense pressure gauge
80
5 6 0
bar 100 x kPa
1
7
psi
40
50
3 4
60
2
R
Dispense pressure regulator
80
Air input quick-connect
Model No. Serial No.
70
20
10
0
90
30
20
0
bar 100 x kPa
7
90
psi
10
0
3
8
0
10 4
5
115V
9
3
Enclosure rating: NEMA 1 or IP100 Time ranges: 0. 005 0. 200 seconds 0. 010 1. 000 seconds (momentary, default) 0. 050 10. 000 seconds 0. 100 20. 000 seconds 0. 015 30. 000 seconds
0
10
9
8
For assistance or to order EFD ULTRA dispensing components, contact your local EFD authorized distributor.
10
0
1200 656964
70
5 6
1
Providence, RI 02914 U. S. A. [. . . ] See www. efd-inc. com for information about how to properly dispose of this equipment. Sales and service of EFD dispensers and dispensing components are available through EFD authorized distributors in over 30 countries. [. . . ]