User manual ENEO VKC-1330IR
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ENEO VKC-1330IR. We hope that this ENEO VKC-1330IR user guide will be useful to you.
Manual abstract: user guide ENEO VKC-1330IR
Detailed instructions for use are in the User's Guide.
[. . . ] Montage und Betriebsanleitung
Farb-Kamera VKC-1330IR12-24, VKC-1330/IR
Installation and Operating Manual
Colour Camera VKC-1330IR12-24, VKC-1330/IR
Mode d'emploi
Caméra Couleur VKC-1330IR12-24, VKC-1330/IR
1
Inhaltsverzeichnis
1. Sicherheitshinweise. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Allgemeine Beschreibung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Anschluss und Bedienung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Pinout
Power Supply at the VKC-1330IR12-24
12VDC
24VAC
G
G
Note
Only switch on the power supply when all the other connections have been carried out. The use of power supply units with stabilised output voltage (12VDC ±10%) is recommended.
3 1 4 2
Connector assignment for DC voltage controlled lenses Description 1 2 3 4 Damping (-) Damping (+) Control (+) Control (-)
Lens connection
AE status of menu should be selected to manual mode and shutter speed is fixed at normal status. A/I switch in dc position To be optimized with LEVEL potentiometer Use only DC voltage controlled lenses with internationally standardized plug pinout.
Signal level Remark
3 1 4 2
Connector assignment for Videosignal controlled lenses Description 1 2 3 4 Supply voltage N. C. Video Ground Colour red white black
Lens connection
AE status of menu should be selected to manual mode and shutter speed is fixed at normal status. A/I switch in video position Optimise via the , , LEVEL" regulator on the AI lens.
20
Signal level
5. Lens Mounting and Adjustment
Lens Mounting
N
Dust protection cap Lens C/CS mount
Remove dust cover N before screwing on the lens. Screw in the lens, and with lenses with automatic iris control, plug the lens cable into the , , LENS" socket. When using a C mount lens, screw on the C mount ring K.
Adjustment
D
LEVEL
Note Video level adjustment
Deactivation of the functions shutter and AGC is recommended for video level adjustment. Once the camera is supplied with voltage and connected to a monitor, undertake sensitivity control on the camera via potentiometer D (when using DC controlled lenses adjust at the camera, when using auto iris lenses adjust at the lens). Appropriately this takes place by means of an oscillograph and a sufficiently illuminated test pattern (min. Should these auxiliary means be unavailable, one must attempt to make an approximate adjustment according to the subjective impression made by the picture, whereby the potentiometer must be turned to the left in the event of an dense picture or to the right in the event of little contrast. (Increase in brightness on the monitor > rotational direction of the LEVEL-potentiometer clockwise. Reduction in brightness on the monitor > rotational direction of the LEVEL-potentiometer anticlockwise). Mean value/peak value control (auto iris lenses only): If the impression made by the picture is unsatisfactory in spite of correctly adjusted level, this may result from strong differences in brightness in the picture (possibly highlight areas), which falsify the adjustment. Continuous adjustment up to 100% peak value control, thus improved recognisability of dense picture sections, is possible by turning the potentiometer to the left.
21
6. Adjustment of Lenses
M
K M
C mount lens
CS mount lens
L
AL
L
Adjustment of flange focus for fixed focus lenses
This adjustment (distance between lens casing and sensor surface) is required if a sharp definition cannot be obtained with the lens focussing, or in order to adjust the position. To obtain a sharp definition, point the camera at an object which is at least 2000 times further away from the front of the lens than the focal length. (If the focal length is 7. 5mm, the object must be at least 15m distant from the camera). If the lens has automatic exposure control, select a dark object, or better use an ND filter (64-x) to ensure that the aperture is fully open. Turn the lens with the CS mount connection until the definition is sharp. When finished, retighten screw M.
Adjustment of flange focus for variable focus lenses
To obtain a sharp definition, point the camera at an object which is at least 5 times the minimum lens distance (MOD) of the lens. (If this is 1m, the object must be at least 5m distant from the camera). [. . . ] Affichage du titre de la caméra, numéro d'identification et position Affichage de l'ensemble des paramètres de la caméra Indication MARCHE / ARR T (l'écran) et PUSHON (tant que la touche est maintenue enfoncée). Réglage du numéro d'identification de la caméra Réglage de la vitesse de communication du port série (9600 / 19200 bauds) Réglage du luminosité. 38 Réglage dé usine AWB
AE
AUTO
ON Normal
OFF
BLC TITLE
OFF
Display
DISP2
000 9600 0 08
EFFECT
D-ZOOM NEGA/POSI B/W MIRROR PIP FREEZE Remarque
PRESET
SYNC INIT LOAD SAVE
DNR Remarque
Activation ou désactivation du zoom numérique Sélection de l'image négative / positive Sélection de la restitution en couleurs ou en noir et blanc Représentation de l'image en miroir sur le moniteur Image dans l'image, MARCHE / ARRET Passe de l'image en direct à l'arrêt sur image (et vice versa) Dans l'entreprise de mise au point et de Zoom-, le mode Freeze est désactivé automatiquement. Synchronisation interne ou ligne Initialisation de la caméra (réglée en usine) Paramètres de la caméra (réglés en usine) Pour conserver la programmation des menus (en cas de panne d'alimentation, etc. ), il faut sauvegarder celle-ci avec l'option SAVE. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ENEO VKC-1330IR
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ENEO VKC-1330IR will begin.