User manual EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER : Download the complete user guide (415 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha COND 1000 Controller/Transmitter uS/cm / mS/cm / ºC ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTO-BAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTO-STIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. [. . . ] 3) Push ENTER key again and use or keys to select between "Pur" and "Lin" temperature coefficients. 4) If "Pur" tC is be selected, press the ENTER key and controller goes back to "tC". If "Lin" tC is selected, press the ENTER key and proceed to step 5. 5) The upper display shows "2. 10%", while the lower display show "P. tC". This option allows you to input the Process Temperature coefficient, from 0 to 10%. Use the or keys to enter the required temperature coefficient value. Next, enter the temperature coefficient of the calibration solution (0 to 10%). 7) Press the or keys to input the desired calibration solution temperature coefficient. 9) Continue with additional Advance setup procedures or return to Measurement mode by pressing the and keys (escape) simultaneously. 13 HOLD SETUP L HOLD SETUP 2. 10 P. HOLD SETUP % ATC 2. 10 C. % ATC Operating Instructions Thermo Scientific Alpha COND 1000 7. 2 1) Temperature Calibration (ATC mode only) HOLD SETUP Enter Advanced Set-up mode. Push the ENTER key and (use or keys to) scroll to Advanced Set-up security code "22". Press the or keys to scroll until the display shows °C "SEt ºC". Compare the current measured temperature on the HOLD SETUP controller display to a thermometer known to be accurate. Press the or keys to scroll the lower display to match the correct value. Continue with additional Advanced Set-up procedures, or return to the Measurement mode by pressing the and keys (escape) simultaneously). 2) 3) 4) 5) 6) 0. 0 7) 8) 7. 2. 1 Setting Manual Temperature Compensation HOLD SETUP NOTE: This parameter is blanked out when the controller is set for ATC operation. For manual temperature compensation, you can set two different temperatures: Process and Calibration. This allows A calibration at a temperature other than your process temperature. Example: setting a calibration temperature of 25 HOLD SETUP ºC lets you calibrate using standard buffer solutions at 25 ºC, °C even if your process temperature is at different temperature. c (use or keys to) scroll to Advanced Set-up security code "22". 2) Press the or keys to scroll until the display shows HOLD SETUP "SEt ºC". c 4) The upper display shows the current process temperature and the lower display shows "P. You can adjust the value from -9. 9 to 125 ºC. FF 25. 0 25. 0 14 Operating Instructions Thermo Scientific Alpha COND 1000 6) After you set the process temperature value, press the ENTER key. [. . . ] 27 Operating Instructions Thermo Scientific Alpha COND 1000 9 TECHNICAL SPECIFICATIONS Conductivity Range 0. 000 to 1. 999 S/cm 0. 00 to 19. 99 S/cm 0. 0 to 199. 9 S/cm 0 to 1999 S/cm 0 to 5000 S/cm 0. 00 to 19. 99 mS/cm 0. 0 to 199. 9 mS/cm Resolution 0. 001 S/cm 0. 01 S/cm 0. 1 S/cm 1 S/cm 5 S/cm 0. 01 mS/cm 0. 1 mS/cm Default Cell Constant, K 0. 01 0. 01 0. 1 1. 0 1. 0 1. 0 10. 0 o Optional Cell, K 0. 1 1. 0 1. 0 o Temperature Resolution Relative Accuracy Sensor Temperature Compensation Set-point and Controller Functions Controller characteristics Pickup / Dropout delay Switching Condutivity hysteresis Contact outputs, controller Switching voltage Switching current Switching power Alarm Functions Function (switchable) Pickup delay Switching voltage Switching current Switching power Electrical Data and Connections Power Requirements Frequency Signal Output Signal Output Load Connection terminal Mains fuse / fine wire fuse EMC Specifications Emissions Susceptibility Environmental Conditions Ambient temp. operating range Relative humidity Mechanical Specifications Dimensions (control panel housing L x H x W) Weights (control panel housing) Material Insulation (Front / Housing) 0-50 C (Display: -9. 9 to 125 C) o 0. 1 C o ± 0. 5 C Pt 1000/Pt 100 o Auto / manual (reference at 25. 0 C) Limit / proportional (pulse or frequency) controller 0 to 1999 sec. 600 VA 110 / 220 VAC (jumper selectable) 48 to 62 Hz 0/4 to 20 mA, galvanically isolated max. 600 Terminal blocks 5-pole / 17-pole, removable slow-blow 250 V / 100 mA According to EN 50081-1 According to EN 50082-1 0 to 50 C 10 to 95%, non-condensing 175 x 96 x 96 mm max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA COND 1000 CONDUCTIVITY CONTROLLER TRANSMITTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.