User manual EUTECH INSTRUMENTS ALPHA COND 560

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA COND 560. We hope that this EUTECH INSTRUMENTS ALPHA COND 560 user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA COND 560 : Download the complete user guide (817 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA COND 560

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha COND 560 Controller mS / µS / ºC / ºF ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. patent 6, 793, 787. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTOBAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTOSTIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. PerpHecT meters are protected by U. S. patents 5, 198, 093, D334, 208 and D346, 753. ionplus electrodes and Optimum Results solutions are protected by U. S. and its subsidiaries. The specifications, descriptions, drawings, ordering information and part numbers within this document are subject to change without notice. This publication supersedes all previous publications on this subject. Preface This manual serves to explain the use of the Alpha COND 560 Controller. [. . . ] If the conductivity reading of the solution is beyond the selected measuring range, calibration error occurs; LCD displays "Or" (over range), "ERR" and flashes electrode annunciator. If calibration error occurs, exit form calibration mode by pressing and keys simultaneously. 4 Calibration is completed. This serves as an indication of the effectiveness of the sensor which will degrade with time and usage. An effective sensor should have a calibration factor of 0. 60 to 1. 40 Press ENT key to return to measurement mode. NOTES: · If you use a 2-cell conductivity sensor, make sure that the pin 1 and 2 are shorted and pin 3 and 4 are shorted on the J10 connector. (Refer section 2 for more details) When calibrating with manual temperature compensation, the controller automatically changes from the preset process temperature to the calibration temperature. After leaving the Calibration mode, the controller switches back to the process temperature (for setting the calibration temperature and the process temperature, see section 5. 3) · WARNING: If you change the measuring range of the controller after calibration is done, the controller will reset back to its factory default calibration. 5 5. 1 SETUP MODE Enter Setup mode The setup mode allows you to customize the settings of the conductivity controller to suite your requirements. LCD shows `SETUP' mode indicator and the first page of setup (rAng ­ Range settings). Press or key to access other pages of the setup mode. MEAS READY µS °C ATC ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT SETUP HOLD ENT ENT NOTES: · To exit setup mode at any time press and keys simultaneously (escape). The controller returns to the measurement mode · If you do not press any key for 2. 5 minutes, the controller automatically exists from the setup mode. 5. 2 Temperature Coefficient Settings Setting the temperature coefficient to match your process/calibration liquids allows controller to achieve conductivity readings with higher accuracy. 1 SETUP HOLD 2 ENT SETUP HOLD 3 SETUP SETUP % HOLD 4 ENT HOLD % ENT ENT 2 SETUP ENT HOLD 1 2 3 4 From measurement mode press ENT key to enter setup mode as described in section 5. 1. Press or key to select temperature coefficient settings screen (tC). Select type of temperature coefficient: The upper display shows the last configured temperature coefficient type (Lin or PUr). Press or key to select the desired type based on type of your process liquid. PUr : Pure water temperature coefficient: Select this if your process liquid is pure water or ultra pure water. Lin : Linear temperature coefficient: Select this for all other process liquids Press ENT key to confirm your selection. If PUr was selected: The controller reverts back to tC screen If Lin was selected: Select temperature coefficient for process liquid: The lower display shows `P. tC'. The upper display shows last configured temperature coefficient for process liquid (if any). Select temperature coefficient for calibration liquid: The lower display shows `C. tC'. The upper display shows last configured temperature coefficient for calibration liquid (if any). The controller reverts to tC screen. Press or key to access other setup screens or press and key simultaneously (escape) to return to measurement mode. 5. 3 Temperature Settings Automatic Temperature Compensation (ATC): The conductivity value of a sample is affected by temperature. Use ATC feature of the controller to compensate for conductivity changes when the temperature of the sample or process liquid fluctuates. Connect a separate temperature probe (Pt100/pt1000) to the controller if an integrated conductivity/Temperature probe is not available. Manual Temperature Compensation (MTC): Set the controller to MTC (disable ATC) when the temperature of sample or process liquid is constant and a temperature probe is not available. [. . . ] coefficients) Linear 25 oC (Both process & calibration temperature) Limit control De-energized 100 µS Low Hysteresis On-delay time Off-delay time Relay 2 (SP2) Set point value Relay function Hysteresis On-delay time Off-delay time Display Backlight 20 µS 0 seconds 0 seconds 1900 µS High 20 µS 0 seconds 0 seconds On 7 7. 1 LIST OF ACCESSORIES Thermo Scientific Order Codes Conductivity Controller Replacement and Accessories Item Description Alpha CON 560 Controller Conductivity cell, Epoxy body, Graphite sensor, w/3-wire Pt100, k = 0. 1 Conductivity cell, Epoxy body, Graphite sensor, w/3-wire Pt100, k = 1. 0 Conductivity 2 Cell type probe, 0. 1 - 200S; Cell constant, K=0. 1 with integrated Pt 100, Material SS316 and 25ft cable (open-ended) Conductivity 2 Cell type probe, up to 200 mS; Cell constant, K=1. 0 with integrated Pt 100, Material SS316 and 25ft cable (open-ended) Order Code TSCONCP0560 ECCONSEN89X ECCONSEN88X ECCS1001S ECCS1010S 7. 2 Eutech Instruments Order Code Conductivity Controller Replacement and Accessories Item Description Alpha COND 560 Controller Eutech Instruments Four-Electrode Conductivity Cell 3/4" NPT(M) 100 Ohm Pt RTD Industrial Conductivity Cells Conductivity Cell; K=0. 1, SS, In-Line; 100 Ohm Pt RTD ATC 100 Ohm Pt RTD Industrial Conductivity Cells Conductivity Cell; K=1. 0, SS, In-Line; 100 Ohm Pt RTD ATC 100 Ohm Pt RTD Industrial Conductivity Cells Conductivity Cell; K=10. 0 CPVC, In-Line; 100 Ohm Pt RTD ATC Order Code 19505-40 19503-00 19500-44 19500-45 19500-46 NOTE: Please contact your authorised distributor or dealer for the prices of extension measuring cables and other accessories such as tee joints, electrode assembly, and calibration solutions. 8 TROUBLESHOOTING Cause a) b) c) Loose connections Incorrect output voltage of the power adaptor Cables not in correct polarity (+ and ­ position) Air bubbles in the probe Dirty probe Probe not deep enough in sample Solution a) b) c) a) b) c) Ensure cables make good contact Use an power adaptor with specified output voltage Re-wire loop cables with correct polarity Tap probe to remove air bubbles Clean probe and recalibrate Ensure that the sample entirely covers the sensor of the probe Ensure shield wire is properly connected to pin 7 Problem Power on, but no display Unstable conductivity reading a) b) c) Oscillating temperature readings Slow response Blinking ATC a) Electrical noise interference a) a) Dirty / Oily probe a) No temperature probe connection during ATC mode Error in calibration Conductivity value of the calibration standard is not within acceptable range a) Clean probe a) Ensure temperature sensing cable makes good contact Ensure calibration standard solution is not contaminated. Ensure electrode is clean Ensure calibration standard is within 10 to 100% of full-scale of the selected measuring range Ensure correct conductivity measurement range is selected Ensure electrode makes good contact with controller Ensure temperature calibration is done properly. Ensure process temperature is within the specified range Blinking electrode annunciator a) b) a) b) Or (Conductivity) a) Or/Ur (Temperature) a) b) Conductivity reading is above the selected measuring range Temperature probe is not connected when ATC enabled Temperature value exceeds above/ below the specified range a) a) b) 9 9. 1 GENERAL INFORMATION Warranty This Controller is supplied with a one-year warranty against significant deviations in material and workmanship from date of purchase and a six-month warranty for probe. Each instrument will have a warranty card with a specific serial number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA COND 560




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA COND 560 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.