User manual EUTECH INSTRUMENTS ALPHA PH 2000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH 2000. We hope that this EUTECH INSTRUMENTS ALPHA PH 2000 user guide will be useful to you.


EUTECH INSTRUMENTS ALPHA PH 2000 : Download the complete user guide (797 Ko)

Manual abstract: user guide EUTECH INSTRUMENTS ALPHA PH 2000

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha pH 2000 Processor/Transmitter pH / ORP ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTO-BAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTO-STIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. [. . . ] If one-point calibration was selected, the display will show the slope and offset. If two-point calibration was selected, the lower section of the display will now show its next lower "pH" buffer. Use and keys to select the second buffer from one of these preset values: - pH 1. 68, pH 4. 01, pH 9. 00, pH 9. 18 and pH 10. 01. Remove the electrode from the first buffer, wash and then immerse it into the second buffer. After calibrating with the second buffer value, the controller will automatically display the slope in the upper and the zero point in the lower section of the display. Note: You can also view the values for zero point and slope without calibration (see section 5. 1. 2 for instruction). The zero point and slope are redetermined after each calibration. 7. Note: If you entered the Calibration mode from the Setup mode, the controller will return to the setup menu. Note: If there is a calibration error the transmitter displays "ERR". In this case, press the and keys simultaneously (escape) to restart the calibration beginning from step 1. Note: When calibrating with manual temperature compensation, the controller automatically changes from the preset process temperature to the calibration temperature. After leaving the Calibration mode, the controller switches back to the process temperature (for setting the calibration temperature and the process temperature, see section 6. 3). 5. 3 ORP­mV Calibration If controller is configured for ORP-mV measuring you can perform only a one-point calibration. SETUP HOLD HOLD CAL MV CAL HOLD MV meas 250 CAL 250 1. Note: If the display reads "CAL PH", see section 6. 9 for procedures on how to switch from pH to ORP-mV readings. The display shows the current mV output of the electrode without any offset adjustment. The controller calculates the correction factor and returns to the Measurement mode. 5. 4 ORP -% Calibration If controller is configured for ORP-% measuring you can perform a calibration at two points using a low concentration sample (20%) and a high concentration sample (80%). To calibrate the controller for ORP %: SETUP HOLD HOLD CAL HOLD CAL meas % 59. 0 CAL CAL 1. Note: If the display reads "CAL PH", see section 6. 9 for procedures on how to switch from pH to ORP-% readings. The display prompts you to place the sensor in the high concentration sample (relative value of 80%). Place sensor in the high concentration sample, then press the ENT key. The unit automatically adjusts its reading to match the solution value. The display prompts you to place the sensor in the low concentration sample (relative value of 20%). Remove the electrode from the first standard, wash it well and then immerse it in the 20% standard. [. . . ] If repair or adjustment is necessary and has not been the result of abuse or misuse within the designated period, please return ­ freight pre-paid ­ and correction will be made without charge. Thermo Scientific/ Eutech will determine if the product problem is due to deviations or customer misuse. Exclusions The warranty on your instrument shall not apply to defects resulting from: · Improper or inadequate maintenance by customer · Unauthorized modification or misuse · Operation outside of the environment specifications of the products 10. 2 Packaging The instrument is packaged in a corrugated box with a warranty card, instruction manual and the following accessories: Wall mount version · Plug, nylon, black, 2 pcs · PG 13. 5, cable gland, 3 pcs · Connectors, 1 each of 3-way (5. 08 mm), 9-way(5. 08 mm), 13-way (3. 5 mm), 8way (3. 5 mm) Panel mount version · Rubber Gasket, 1 pc · Catch, 2 pcs · Rod, thread, 2 pcs · Connectors, 1 each of 3-way (5. 08 mm), 9-way (5. 08 mm) and 19-way (3. 5 mm). 10. 3 Return of Goods Authorization must be obtained from our Customer Service Department or authorized distributor before returning items for any reason. A "Return Goods Authorization" (RGA) form is available through our authorized distributor. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH 2000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH 2000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.