User manual FLUKE 87 TRUE RMS MULTIMETER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE 87 TRUE RMS MULTIMETER. We hope that this FLUKE 87 TRUE RMS MULTIMETER user guide will be useful to you.


FLUKE 87 TRUE RMS MULTIMETER : Download the complete user guide (266 Ko)

Manual abstract: user guide FLUKE 87 TRUE RMS MULTIMETER

Detailed instructions for use are in the User's Guide.

[. . . ] ® True RMS Multimeter 87 Users Manual PN 834192 August 1988 Rev. 8, 4/97 © 1988, 1989, 1990, 1992, 1993, 1994, 1997 Fluke Corporation. All product names are trademarks of their respective companies. Interference Information This equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. Operation is subject to the following two conditions: · This device may not cause harmful interference. [. . . ] In the 1 s High Accuracy MIN MAX Recording Mode, the recording speed is 1 second. 1 ms Peak MIN MAX Recording Mode Input changes of 1 millisecond or longer will be recorded. Automatically indicates negative inputs. Beeper Z RECORD Minimum, Maximum, and Average Recording W Continuity test is enabled. Items 24 through 31 describe math function annunciators and the annunciators that indicate the units of the value displayed. Readings are being recorded in the MIN MAX Recording mode. A maximum (MAX), minimum (MIN), or average (AVG) reading can be displayed. 27 MAX Maximum Value in MIN MAX Recording Mode X Relative Mode The value displayed is the maximum reading taken since the MIN MAX Recording mode was entered. The value displayed is the difference between the present measurement and the previously stored reading. See item 12. Y 16 100 ms Normal Recording Speed in MIN MAX Recording Mode Applications 28 MIN Minimum Value in MIN MAX Recording Mode The value displayed is the minimum reading taken since the MIN MAX Recording mode was entered. 29 AVG Average Value in MIN MAX Recording Mode The value displayed is the true average of all readings taken since the MIN MAX Recording mode was entered. 30 H Nanosiemens (1 x 10 siemens). Conductance (1/) % Percent Annunciator (for duty cycle readings only) Ohms. Capacitance nS 32 -9 Hold The meter is operating in a Display Hold mode. See item 10 for Display Holds. 31 The following annunciators indicate the unit of the Duty Not Used Not Used Holster and Flex-Stand The meter comes with a snap-on holster that absorbs shocks and protects the meter from rough handling. Some uses of the holster with Flex-Stand are shown in Figure 2. value displayed: AC DC V mV A mA uA Alternating current or voltage Direct current or voltage Volts -3 Millivolts (1 x 10 volts) Ampere (amps). Current -3 Milliampere (1 x 10 amps) -6 Microampere (1 x 10 amps) Applications This section discusses some common applications for your meter, and alerts you to some considerations to keep in mind when taking measurements. 17 87 Users Manual Holster With Flex-stand Bent Holster With Flex-stand Extended Holster With Probe In Clip POWER-UP OPTIONS PRESS 2 SEC. WHILE TURNING METER ON LOW, OHMS/HIGH RESOLUTION ZERO MIN MAX RANGE HOLD ALERT RPM DISABLE AUTOMATIC POWER-OFF HI ACCURACY, 1 SEC. RESPONSE AUTORANGE VDC, VAC HI IMPENDANCE mV DC INPUT TURN OFF BEEPER TEST ROTARY SWITCH WARNING TO AVOID ELECTRICAL SHOCK REMOVE TEST LEADS BEFORE OPENING CASE TO PREVENT DAMAGE OF INJURY INSTALL QUICK ACTING FUSES WITH AMP/VOLT RATINGS SHOWN. F 1A 600V MIN INTERRUPT RATING 10 000A F 15A 600V MIN INTERRUPT RATING 10 000A _ + 9V NEDA 1604 6F 22 006P JOHN FLUKE MFG. PATENTS PENDING FLUKE AND PHILLIPS THE T & M ALLIANCE Holster With Flex-stand Looped Over Car Door Meter In Holster Face Down For Protection (Store Quick Reference Card Under Meter) Holster With Flex-stand Looped Over Belt ep2f. eps Figure 2. Holster and Flex-Stand 18 Applications Measuring Voltage (AC/DC) To measure voltage, connect the meter in parallel with the load or circuit under test. Each of the five ac/dc voltage ranges presents an input impedance of approximately 10 M in parallel with less than 100 pF. To improve the accuracy of dc voltage measurements made in the presence of ac voltages, measure the ac voltage first. Note the ac voltage range and manually select a dc voltage range that is the same or higher than the ac voltage range. This method improves the dc voltage accuracy by ensuring that the input protection circuits are not being activated. A typical application is measuring the dc offset voltage of an amplifier in the presence of an ac signal. Measurement errors due to circuit loading can result when making either ac or dc voltage measurements on circuits with high source impedance. In most cases, the error is negligible (0. 1% or less) if the measurement circuit source impedance is 10 kilohms or less. Measuring Current Warning Do not attempt an in-circuit current measurement where the potential to earth is greater than 1000V. [. . . ] To locate an authorized service center, call Fluke using any of the phone numbers listed below, or visit us on the World Wide Web: www. fluke. com 1-800-443-5853 in U. S. A and Canada 31 40 267 8200 in Europe 206-356-5500 from other countries Replaceable Parts Note When servicing the meter, use only the replacement parts specified. Replaceable parts are shown in Figure 5 and listed in Table 7. To order outside the USA, contact the nearest Service Center. 33 87 Users Manual Table 7. Replaceable Parts Item BT1 F1 P F2 P H1 MP1 MP2 TM1 TM2 TM3 Description Fluke Part Number Quantity Battery, 9V 614487 1 Fuse, F44/100A, 1000 VAC/DC 943121 1 Fuse, F11A, 1000 VAC/DC 943118 1 Screw, Case 832246 3 Foot, Non-Skid 824466 2 O-Ring, Input Receptacle 831933 1 Users Manual, Fluke 87 (English) 834192 1 Users Manual, Fluke 87 (International) 834200 Service Manual, CAT III labeled meters 617826 all other meters 834168 TM4 Quick Reference Guide, Fluke 80 Series 844290 1 TL20** Industrial Test Lead Set (Optional) TL75** Test Lead Set 1 C81Y** Holster, Yellow 1 C81G** Holster, Gray (Optional) C25** Carrying Case, Soft (Optional) P To ensure safety, use exact replacement only. ** Items marked with two asterisks are Fluke accessories and are available from you authorized Fluke distributor. 34 Replaceable Parts F2 F1 C81Y, C81G TL75 MP2 BT1 H1 MP1 ep5f. eps Figure 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE 87 TRUE RMS MULTIMETER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE 87 TRUE RMS MULTIMETER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.