User manual FLUKE MFC SWITCHBOX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE MFC SWITCHBOX. We hope that this FLUKE MFC SWITCHBOX user guide will be useful to you.


FLUKE MFC SWITCHBOX : Download the complete user guide (279 Ko)

Manual abstract: user guide FLUKE MFC SWITCHBOX

Detailed instructions for use are in the User's Guide.

[. . . ] MFC SwitchboxTM User's Manual © 1997-2008 DH Instruments, a Fluke Company High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. © 1997-2008 DH Instruments, a Fluke Company All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, a Fluke Company 4765 East Beautiful Lane Phoenix AZ 85044-5318 USA. [. . . ] This is accomplished using the setup function to define the MFC profile. For details on the MFC profile definition, see the molbox1 or MFC-CB Operation and Maintenance Manual. In order to support MFM calibrations using the MFC Switchbox the device type is specified to the MFC profile. After entering the MFC range, you will be prompted to enter the device type. The device type for any voltage based profile can be either `measure' or `control'. If the profile indicates measure, then channel one will be used for control whenever the channel is selected that is associated with this profile. If the profile indicates control, then the selected channel will be used for both measurement and control. When calibrating MFMs, the range of the MFC setup for channel 1 must be wide enough to cover the range of all the MFMs being calibrated on the other channels. For details on configuring the MFC channels and profiles see the molbox1 or MFC-CB Operation and Maintenance Manual. Once the MFC channels have been configured using the setup menu, the MFC channel can be selected by pressing the MFC function key on the molbox1 or MFC-CB front panel. When the MFC function key is first pressed the screen prompts the operator to select the MFC channel (<0> disables). The MFC Switchbox must be connected to the molbox1 or MFC-CB at the time of this selection, but does not have to be connected during the MFC setup described above. Entering <1>, <2>, <3>, <4> or <5> selects the corresponding channel on the MFC Switchbox and enables the MFC function. When not using the MFC Switchbox, select Channel #1 when activating the MFC function. The profile number that is associated with the selected channel is automatically displayed. This screen allows the operator to override the profile selection made during setup. When the profile number desired is entered a summary of the profile is displayed. When [ENTER] is pressed again, the display returns to the main run screen and the MFC function is active using the MFC profile selected. The MFC Switchbox must be connected to the molbox1 prior to pressing [ENTER] or the message that actually triggers the switching inside the MFC Switchbox will be missed. With molbox1, the text <MFCn> or <MFMn> (where n is the channel number and the type depends on the channel configuration) will be displayed in the bottom right hand corner of the main run screen. With MFC-CB, the text <Dn, c> (where n is the number of the active MFC-CB channel and c is the number of the active MFC Switchbox channel. When the MFC function is active, pressing [ENTER] from the main run screen or an MFC run screen allows entry and execution of the MFC setpoint command. Page 7 © 1997-2008 DH Instruments, a Fluke Company MFC SWITCHBOX USER'S MANUAL When the selected channel is associated with a `measure' profile type, the control signal is sent to the device on channel 1. This setpoint must be set in voltage and will set flows according to the range specified in the profile for the device connected to channel 1. [. . . ] An MFC Switchbox can be connected to the output to switch between multiple devices. Command: "MFCCH=1, mA" Enables MFC for current Reply: "1, mA" Command: "MFCCH=3, V" Enables MFC on switchbox channel 3 for volts Reply: "3, V" Command: "MFCCH=0" Disables MFC interface (0 is used on molbox1 only) Reply: "0, V" Channel or mode arguments invalid ERR# 6: The MFC option is not installed (molbox1 only) ERR# 23: Channel greater than 1 and MFC Switchbox accessory is not installed ERR# 23: This command in molbox1 or MFC-CB Operation and Maintenance Manual. Page 9 © 1997-2008 DH Instruments, a Fluke Company MFC SWITCHBOX USER'S MANUAL NO T E S © 1997-2008 DH Instruments, a Fluke Company Page 10 5. MAINTENANCE AND ADJUSTMENTS 5. MAINTENANCE AND ADJUSTMENTS OVERVIEW 5. 1 There are no user maintainable parts or systems in the MFC Switchbox. Page 11 © 1997-2008 DH Instruments, a Fluke Company MFC SWITCHBOX USER'S MANUAL NO T E S © 1997-2008 DH Instruments, a Fluke Company Page 12 6. TROUBLESHOOTING 6. 6. 1 TROUBLESHOOTING SYMPTOMS / CAUSES / SOLUTIONS Table 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE MFC SWITCHBOX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE MFC SWITCHBOX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.