User manual FLUKE MPG1 WITH PG7302 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE MPG1 WITH PG7302. We hope that this FLUKE MPG1 WITH PG7302 user guide will be useful to you.


FLUKE MPG1 WITH PG7302 INSTALLATION: Download the complete user guide (95 Ko)

Manual abstract: user guide FLUKE MPG1 WITH PG7302INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Interconnection Kit For MPG1 with RPM4 or PG7302 P/N 402265 Instruction Sheet INTERCONNECTION KIT FOR MPG1 WITH RPM4 OR PG7302, P/N 402265, INCLUDES: DESCRIPTION PRESSURE RATING QTY PART NO. Nipple, 6 in. (127 mm x 3 mm), DH500 tips Tee DH500 Plug DH500/DH700 Adaptor, DH500F x 1/8 in. [. . . ] nipples: Slide a gland over a nipple so that the threads of the gland face outward. Allow two nipple threads to show between the collar and nipple tip. a Figure 1: Two nipples installed in 3-way tee. Optional: Extend the front feet on RPM4: The front feet of the RPM4 can be extended so that the RPM4 is inclined for easier reading and display access. Wrap Teflon® thread tape around the NPT threads of the adaptor three times, and install the adaptor into the RPM4. Install the free end of the center nipple into RPM4 or PG7302: The center, thin, 5 in. The nipple can be bent slightly to ensure that nipple enters straight into the test port. Do not tighten the gland in the RPM4 or PG7302 yet, since it will be tightened when the system is primed. RPM4 ­ Install glands and collars onto the 6 in. Install a DH500M to 1/8" NPT male adaptor in the DUT if necessary: The 1/8 in. If you intend to use the adaptor, wrap Teflon® thread tape around the NPT threads three times and install it into the DUT. The DUT will be connected to the test line with the remaining thin 5 in. This nipple can be installed either in the 3-way tee, or in the port on top of the MPG1. Tighten the gland in the tee or MPG1, but do not tighten the gland that connects to the DUT. Plug the open test port: There is an open test port either on the top of the MPG1, or on the 3-way tee. [. . . ] Energy stored in pressurized fluids can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. ALWAYS use external tubing and fittings rated for pressures equal to or greater than the maximum pressure which MPG1 will be used to generate. Document 560080b 070208 DH Instruments, Inc. 4765 East Beautiful Lane Phoenix AZ 85044-5318 USA Tel 602. 431. 9100 Fax 602. 431. 9559 dhi@dhinstruments. com www. dhinstruments. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE MPG1 WITH PG7302




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE MPG1 WITH PG7302 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.