User manual FLUKE MPG2-H WITH PG7302 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE MPG2-H WITH PG7302. We hope that this FLUKE MPG2-H WITH PG7302 user guide will be useful to you.


FLUKE MPG2-H WITH PG7302 INSTALLATION: Download the complete user guide (307 Ko)

Manual abstract: user guide FLUKE MPG2-H WITH PG7302INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Interconnection Kit For MPG2-H with RPM4 or PG7302 P/N 3367797 Instruction Sheet Interconnection kit for MPG2-H with RPM4 or PG7302, P/N 3367797, includes: DESCRIPTION PRESSURE RATING QTY PART NO. a RPM4 ­ Install glands and collars onto the 12 in. x 1/8 in. (127 mm x 3 mm), DH500, flexible Elbow DH500 Tee DH500 Union DH500 Plug DH500/DH700 Adaptor, DH500F x 1/8 in. [. . . ] Install the free end of the center nipple into RPM4 or PG7302: The center, 2. 75 in. Do not tighten the gland in the RPM4 or PG7302 yet, since it will be tightened when the system is primed. Install a DH500M to 1/8" NPT male adaptor in the DUT if necessary: The 1/8 in. If you intend to use the adaptor, 1 1 1 1 2 3068361 3068501 3068520 3068470 3068785 Introduction This kit provides the tubing and fittings necessary to connect an MPG2-H pressure controller to either an RPM4 reference pressure monitor or to a PG7302 piston gauge, and also to a device under test. This document contains instructions for connecting the fittings and tubing. Installation of Interconnections Remove Plugs from MPG2-H, Tee, Union and RPM4 or PG7302: Unscrew the glands from the test ports of the MPG2-H and RPM4 or PG7302. nipple: Slide a gland over a nipple so that the threads of the gland face outward. Use collars and glands from tee, elbow and union. wrap Teflon® thread tape around the NPT threads three times and install it into the DUT. The DUT will be connected to the test line with the remaining flexible 5 in. This nipple can be installed either in the 3-way tee, or in the port on top of the MPG2-H. Tighten the gland in the tee or MPG2-H, but do not tighten the gland that connects to the DUT. Plug the open test port: There is an open test port either on the top of the MPG2-H, or on the 3-way tee. Prime the system, tighten fittings: Pump fluid through the nipples by using the MPG2-H. [. . . ] High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. · ALWAYS use external tubing and fittings rated for pressures equal to or greater than the maximum pressure which MPG2-H will be used to generate. Figure 1: Nipples installed in 3-way tee, elbow and union Document 3367676 081001 DH Instruments, a Fluke Company 4765 East Beautiful Lane Phoenix AZ 85044-5318 USA Tel 602. 431. 9100 Fax 602. 431. 9559 dhi@dhinstruments. com www. dhinstruments. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE MPG2-H WITH PG7302




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE MPG2-H WITH PG7302 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.