User manual FLUKE PG7202 V2.03

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE PG7202. We hope that this FLUKE PG7202 user guide will be useful to you.


FLUKE PG7202 V2.03: Download the complete user guide (2109 Ko)

You may also download the following manuals related to this product:

   FLUKE PG7202 V3.0 (3120 ko)
   FLUKE PG7202 V2.07 (3482 ko)

Manual abstract: user guide FLUKE PG7202V2.03

Detailed instructions for use are in the User's Guide.

[. . . ] 2. 03 and Higher) Operation and Maintenance Manual PG7000TM PISTON GAUGES PG7102TM, PG7202TM, PG7302TM, PG7601TM ©1998-2002 DH Instruments, Inc. PG7000TM OPERATION AND MAINTENANCE MANUAL High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. © 1998 - 2002 DH Instruments, Inc. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, Inc. [. . . ] These values will be used by PG7000 in calculating defined pressure, piston-cylinder range and pressure to mass and mass to pressure values when the piston-cylinder module is made active by selecting pressing [P-C]. The information needed can be found in the calibration report for the piston-cylinder module. © 1998-2002 DH Instruments, Inc. Page 94 3. GENERAL OPERATION Setting up or editing a piston-cylinder module requires specifying, in sequential order, the following: Serial number (S/N) [nnnn]. OPERATION Adding or editing a piston-cylinder module requires the user to specify a large number of variables in a series of data entry screens described below. For a summary of the piston-cylinder module data requirements in the order they are edited see PRINCIPLE in this section. PG7000 can store up to 18 piston-cylinder module (PC) files. When <3add> is selected and all the files have already been used, a warning is displayed. To create a new piston-cylinder module press [SPECIAL] and select <1PC/MS>, <1PC>, <3add>. Edit each menu to reflect the correct information on the piston-cylinder module being added. Pressing [ESCAPE] at any point offers an <Abandon edits?> query and then returns to the <1PC> menu without saving any of the edited data or returns to the add piston-cylinder module process. The data entry screens to add or edit a piston-cylinder module are, in order: · · Serial number (S/N): Edit the serial number using four digits. Effective area at 0 pressure and 20 °C: Edit the value of the pistoncylinder effective area at 0 pressure and 20 °C. This value is reported in the calibration report for the piston-cylinder module. Piston temperature coefficient: Edit the value of the piston material linear thermal expansivity. The value must be entered in terms of relative change per degree centigrade [nnE-6/°C]. This value is reported in the calibration report for the piston-cylinder module. The default is 00. Page 95 © 1998-2002 DH Instruments, Inc. · PG7000TM OPERATION AND MAINTENANCE MANUAL · Cylinder temperature coefficient: Edit the value of the cylinder material linear thermal expansivity. The value must be entered in terms of relative change per degree centigrade [nn x 10-6/°C]. This value is reported in the calibration report for the piston-cylinder module. Effective area pressure coefficient: Edit the value of the piston-cylinder change in effective area in terms of relative change per MegaPascal [n. nn x 10-6/MPa]. This value is reported in the calibration report for the piston-cylinder module. Piston-cylinder surface tension effect: Edit the value of the surface tension effect of the pressurized fluid on the piston. This value is reported in the calibration report for the piston-cylinder module. [. . . ] The mass loaded on the piston in terms of the nominal values written on the individual masses. Piston-cylinder, piston-cylinder module. Absolute by vacuum, avac Absolute by atmosphere, aatm Adder Ae ATM Head Crossfloat Differential DUT (Device Under Test) DUT Head FS (Full Scale) g, gl Gauge He Head High Line Differential HSTOP, LSTOP InHg InWa kcm 2 Line Pressure Measurement Mode MS (Mass Set) Mass Bell Mass Entry Mode (mass to pressure) Medium, pressurized Multiplier N2 Nominal Mass Normal PC Page 189 © 1998-2002 DH Instruments, Inc. PG7000TM OPERATION AND MAINTENANCE MANUAL Pressure Entry Mode (pressure to mass) PISTON head PRT Ready/Not Ready Reference Level Reference PG7000 SETUP file Static Pressure Tare PG7000 True Mass User Level Operating mode in which the user enters the pressure to be defined and PG7000 calculates the mass to load. Fluid head correction based on the difference between the piston's current position and the reference level. The element used in the piston-cylinder mounting post to measure temperature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE PG7202




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE PG7202 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.