User manual FLUKE PPCH-G

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUKE PPCH-G. We hope that this FLUKE PPCH-G user guide will be useful to you.


FLUKE PPCH-G : Download the complete user guide (3523 Ko)

You may also download the following manuals related to this product:

   FLUKE PPCH-G INSTRUCTION SHEET (182 ko)

Manual abstract: user guide FLUKE PPCH-G

Detailed instructions for use are in the User's Guide.

[. . . ] Operation and Maintenance Manual PPCH-GTM High Gas Pressure Controller/Calibrator © 2007 DH Instruments, a Fluke Company High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. This instrument is not to be operated in any other manner than that specified by the manufacturer. © 2007 DH Instruments, a Fluke Company All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, a Fluke Company 4765 East Beautiful Lane, Phoenix AZ 85044-5318, USA. [. . . ] PPCH-G goes through its power up sequence after any type of reset is executed. PPCH-G reset functions will change current settings to factory defaults. These may include settings vital to PPCH-G operation and affecting the calibration of the quartz reference pressure transducers (Q-RPTs). Reset functions should only be used by qualified personnel with knowledge of reset consequences. Reset functions should not be used experimentally. Page 75 © 2007 DH Instruments, a Fluke Company PPCH-GTM OPERATION AND MAINTENANCE MANUAL OPERATION To access the RESET menu, press [SPECIAL], <4reset>. The display is: RESET menu choices include: <1set> <2units> <4cal> <5all> to reset general system operating parameters (see Section 3. 5. 4. 1). 1sets 2units 3ATest 4cal 5all <3ATest> to reset AutoTest parameters and clear the AutoTest data log (see Section 3. 5. 4. 3). to reset internal calibration coefficients and modes (see Section 3. 5. 4. 4). to reset all settings except ID and security password to factory default values (see Section 3. 5. 4. 5). 3. 5. 4. 1 <1SETS> PURPOSE Sets most general operating parameters back to default values. Does not affect calibration coefficients, remote interfaces or AutoRange ranges. Reset ­ Sets RESET [UNIT] [MODE] [RANGE] [HEAD] Control Mode Control Limits Upper Limit Resolution AutoZ Leak Check Screen Saver Key Sounds TPC Config RESULT Returns pressure unit of measure to first of six available. Medium Return to factory control coefficients SEE SECTION 3. 3. 2 3. 3. 3 3. 3. 1 3. 3. 7 3. 4. 6 3. 4. 6. 1 3. 4. 4 3. 4. 2 3. 5. 1 3. 3. 9 3. 5. 5. 1 3. 5. 5. 2 3. 5. 7. 1 3. 5. 4. 2 <2UNITS> PURPOSE Sets the six pressure units available under the UNIT function to the SI or US default selections depending on whether the PPCH-G has been factory set for SI or US (see Section 3. 3. 2). Sets the user defined unit to 1. 000/Pa (see Section 3. 5. 6). © 2007 DH Instruments, a Fluke Company Page 76 3. OPERATION 3. 5. 4. 3 · · <3ATEST> PURPOSE Resets Quick Test and Q-DUT Tests to default (see Section 3. 3. 6). Clears AutoTest data log (see Section 3. 4. 5). 3. 5. 4. 4 <4CAL> PURPOSE The Reset - Cal function will reset Q-RPT, utility sensor and barometer calibration coefficients and settings and reset AutoZ values to zero. This will change the PPCH-G calibration and could cause it to make out of tolerance measurements. Clears all user values affecting the calibration of Q-RPTs, utility sensor and the on-board barometer. Reset ­ Cal RESET All Q-RPT user calibration coefficients Q-RPT absolute mode Utility Sensor calibration coefficients On-board barometer calibration coefficients Calibration date AutoZ values AutoZ function RESULT PA to zero, PM to 1. All Poffset values to zero for absolute mode and 101325 Pa for gauge modes. SEE SECTION 5. 2. 1. 1, 5. 2. 7 5. 2. 5 5. 4 5. 3 5. 2. 7, 5. 4, 5. 3 3. 5. 1 3. 5. 1 3. 5. 4. 5 <5ALL> PURPOSE The reset - all function clears and deletes large amounts of user defined information including critical calibration data. Combines all resets in one global reset command that clears the entire user section of non-volatile memory returning PPCH-G to the "as delivered" condition except the ID function (see Section 3. 5. 5. 4) and the security level password (see Section 3. 5. 5. 5). The Reset ­ All resets are itemized in Table 12. Page 77 © 2007 DH Instruments, a Fluke Company PPCH-GTM OPERATION AND MAINTENANCE MANUAL Table 12. [. . . ] The difference between a Q-RPT reading and the AutoZero reference at the time AutoZ is run. Used by the AutoZ function when Auto Z is ON to compensate Q-RPT readings for changes in zero over time. Value indicated by the device against which the Q-RPT is zeroed by AutoZ. Pressure adder, used to offset a Q-RPT, utility sensor or barometer to calibrate it. Pstd, 0 PA Page 149 © 2007 DH Instruments, a Fluke Company PPCH-GTM OPERATION AND MAINTENANCE MANUAL PM Q-RPT (Reference Pressure Transducer) Pressure multiplier, used to adjust span of a Q-RPT, utility sensor or barometer to calibrate it. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE PPCH-G




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE PPCH-G will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.