User manual FUTABA FSU2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FUTABA FSU2. We hope that this FUTABA FSU2 user guide will be useful to you.


FUTABA FSU2 : Download the complete user guide (65 Ko)

Manual abstract: user guide FUTABA FSU2

Detailed instructions for use are in the User's Guide.

[. . . ] Otherwise, move on to the next step, "How to change the activation voltage of B-F/S function". 3 Under this condition, push the setting switch How to change the activation voltage of B-F/S function FOREWORD Thank you for purchasing an FSU2 Fail Safe Unit. This FSU2 is simple to install - just connect it between the receiver and servo. Therefore, please read this manual carefully and use your FSU2 correctly. 1 Connect the FSU2 between the receiver and the throttle servo. 4 Now, turn off the power of the transmitter, 2 Turn on the power of the transmitter first. [. . . ] Do not connect the FSU2 to reverse polarity. * Repair may be impossible. NOMENCLATURE AND SETTING Monitor Lamp (LED) Monitor lamp will light at F/S condition and repeat turning on and off at B-F/S condition. At normal condition, monitor lamp will blink once or twice depending on the preset activation voltage of B-F/S function. It is adequate that the monitor lamp blinks once for a four-cell NiCd battery and twice for a five-cell NiCd battery. Setting Switch (Set) This is the switch to set the activation voltage of B-F/S function and to set the servo position for F/S function. Do not use the FSU2 where it will be directly exposed to water, oil, etc. *The FSU2 does not have waterproof construction. When using the FSU2 where it may be exposed to water, exhaust gas, etc. , waterproof it by placing the unit in a leakproof plastic bag and securing the open end of the bag with a rubber band. Do not connect more than one servo to the output side of the FSU2. Install the FSU2 where it will not directly touch other parts, even if the model crashes. Servo Connector To Receiver DESCRIPTION OF OPERATION NORMAL OPERATION The FSU2 relays the signal from wheel, triger, or stick to its corresponding servo without any delay under the normal operation. REPAIR SERVICE Before requesting repair, please refer to this instruction manual again and verify your settings. If you are still experiencing trouble, please request service as follows: Address Your nearest Futaba dealer. Repair information Describe the trouble in as much detail as possible. Digital proportional set used: Transmitter, receiver, and servo model numbers. SPECIFICATIONS Usable receiver power supply Nicd 4 cells (4. 8V): Cells with a capacity of 270mAh or more Nicd 5 cells (6. 0V): Cells with a capacity of 500mAh or more 6V supplied by BEC internal control amp or regulator Operating voltage 3-7V B-F/S detection voltage 4. 8V mode: 4. 0 ± 0. 3V 6. 0V mode: 5. 0 ± 0. 3V Current drain Approx. 10mA Input/output pulse width 900-2140µsec Input/output frame width 7. 8-22. 8msec Size / Weight 15. 8x21. 8x7. 7mm (excluding projecting parts) / 6g F/S FUNCTION OPERATION Operation by interference When the interference is weak, the servo horn will intermittently try to move to the F/S set position. If the set position is correctly set at the brake or throttle slow side, it will be difficult for the throttle to fly up and the FSU2 will return the servo to the throttle slow side. When interference is strong, the F/S function will hold the throttle servo in the preset position. When the interference disappears, the FSU2 will immediately return to the normal operation. When there is strong interference on the same band nearby and the F/S function is turned on instantly, the other transmitter will control the model. In this case, just because the FSU2 is installed does not mean that loss of control can be prevented. Be very careful during use. NOTE Most of the functions of this product are performed by CPU. [. . . ] Procedures which may lead to a dangerous condition or cause death or serious injury to the user if not carried out properly, or procedures where the probability of superficial injury or physical damage is high. Procedures where the possibility of serious injury to the user is small, but there is a danger of injury, or physical damage, if not carried out properly. WHEN POWER SUPPLY VOLTAGE DROPS TO 3V OR LESS Since the CPU does not operate normally, the connected servos do not operate normally. Of course, the F/S and B-F/S functions do not operate normally either. Special Markings; Pay special attention to the safety at the parts of this manual that are indicated by the following marks. Symbol: ; Prohibited ; Mandatory OTHERS This product is designed, manufactured, and sold for use with R/C models. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FUTABA FSU2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FUTABA FSU2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.