User manual GE INTERLOGIX SIMON 2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GE INTERLOGIX SIMON 2. We hope that this GE INTERLOGIX SIMON 2 user guide will be useful to you.


GE INTERLOGIX SIMON 2 : Download the complete user guide (1064 Ko)

Manual abstract: user guide GE INTERLOGIX SIMON 2

Detailed instructions for use are in the User's Guide.

[. . . ] 466-1574 Rev E Dated March 1999 Table of Contents Simon® Basic : 2 Special Installation Requirements 3 Requirements for UL-Listed Installations 3 Canada Listings (pending) 3 California State Fire Marshall Listing 3 Introduction 4 System Components 4 Planning Sensor Types & Locations 7 Planning Control Locations 10 Planning for Lamp*, Appliance*, Wallswitch*, and Universal/Garage Door* Module Control 10 Setting the House Code and Unit Number 10 Programming Overview 26 Programming Sensors 27 Programming the House Code and Unit Numbers* 28 Programming Light and Appliance Controls* 28 Programming Options 29 Programming System Access Codes 30 Installing the System 31 Control Panel General Information 31 Control Panel Specifications 31 Installation Guidelines 31 Sensor Installation 32 Testing the Control Panel 32 Planning System Access Codes 12 Utility Access Code 1 12 Utility Access Code 2 12 Master Access Code 12 Access Codes (1 - 5) 12 Panic Code 12 Testing the System 32 Testing Sensors 33 Sensor Tripping Instructions: 33 If a Sensor Fails the Sensor Test 34 Planning System Options 12 Reset Memory to the Factory Defaults 20 Wiring the Control Panel 23 Connecting Hardwire Interior Sirens 23 Connecting a Hardwire Exterior Siren 23 Connecting Hardwire Sensors 23 Connecting the Universal/Garage Door Opener Module* 24 Connecting the Power Transformer 24 Connecting the Backup Batteries 24 Installing a Non-rechargeable Battery 24 Installing a Rechargeable Battery 25 Connecting the Phone Line to the Control Panel 25 Installing an RJ-31X Jack 25 Connecting the Phone Line to the Control Panel 25 Testing Phone Communication 34 Testing Central Station Communication 34 Testing the X-10 Lamp Modules* 35 Siren and X-10 Lamp Module Functions* 35 Panel Tamper 35 Troubleshooting 36 Typical Backup Battery Life of the 9 Volt UltraLife 38 Notices 39 Index 40 Quick Reference Guide 44 Attachment: 466-1622, Booklet of Installation Instructions for SAW Sensors 1 . Simon® Basic : Features not Available with the Simon® Basic ITI # 60-776-02-95R Modules that Cannot be Used with Simon® Basic Interrogator 200 Audio Verification Module® (AVM) (60-787) X-10 Lamp (13-403) 2-Way Voice Remote Phone Control Speaker Volume Control Chime Special Motion Light Control Wireless Sirens Appliance (13-402) Powerhorn/Remote (13-398) Universal/Garage Door (13-399) Wall Switch Modules (13-397) Touchtalk 2-Way RF Touchpad (60-788-95R) Supervised Wireless Siren SWS (60-736-95) Options not for Use with Simon® Basic Option 33: 2-Way Voice Option 36: Sensor Activated Light Lockout Start Time Option 37: Sensor Activated Light Lockout Stop Time Option 42: Speaker Level Option 46: Fire Shutdown - AVM Option 47: AVM Mode Option 48: Panic Talk 2 Installation Instructions Document No. 466-1574 Special Installation Requirements This security system can be used as a fire warning system, an intrusion alarm system, an emergency notification system, or any combination of the three. Some installations may require certain configurations dictated by city codes, state codes, or insurance requirements. The following information indicates the components of various listings. Residential Fire Alarm System Unit (UL 985) Basic system above, plus: · System Sensor Smoke Sensor (60-506-95) Canada Listings (pending) Residential Burglary Alarm System Unit (ULC-S309) Basic system as described for UL-listed installations, plus: · Door/Window Sensor (60-670-95R) Requirements for UL-Listed Installations This section describes the minimum system configurations for UL-listed, Grade A (supervised) systems. [. . . ] Option 53: Hardwire Siren Supervision Add turns hardwire siren supervision on. Turn this option on if installing a hardwire siren and supervision is desired. See the "Wiring the Control Panel" on page 23 for the correct EOL resistor connection. Delete turns hardwire supervision off and is the appropriate setting if hardwire sirens are not being connected. Reset Memory to the Factory Defaults If it becomes necessary to set all programming back to the factory defaults, do the following: 1. Restore power to the panel with either the battery or the transformer while pressing these three buttons. Plug in the transformer or connect the battery. NOTE: If Phone Lock is on, options 04, 05, 06, 08, 09, 12, and 13 will not reset to their defaults. 20 Installation Instructions Document No. 466-1574 Table 18 Programmable Options Who Can Change: U1 - Utility Access Code 1; U2 - Utility Access Code 2; M - Master; U1 U2 M U1 U2 M U1 U2 M U1 U1 U1 U1 U2 U1 U1 U1 U2 U1 U2 U1 U1 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 Option # Function Default Delete Range Installer Settings 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Panel Piezo Beeps Panel Voice Latchkey Option Primary Phone Number Secondary Phone Number Downloader Phone Number Account Number Phone Lock Downloader Code Entry Delay Exit Delay Phone Mod 1 Phone Mod 2 DTMF No Activity Report Auto Phone Test (Must be enabled for UL Listed systems) Dialer Delay Alarm Cancel Report Supervisory Time (SUPSYNC) Manual Phone Test Opening Reports Closing Reports Force Armed Report AC Power Failure Report (Must be enabled for UL Listed systems) CPU Low Battery Report (Must be enabled for UL Listed systems) Fail to Communicate (Must be enabled for UL Listed systems) Ring/Hang/Ring On On Off None None None 00000 Off 12345 030 sec 030 sec 0 0 On Off Off Off Off 12 hrs On Off Off Off Off On On 1 Off Off Off None None None 00000 Off 12345 005 sec 005 sec 0 0 Pulse Off Off Off Off 02 hrs Off Off Off Off Off Off Off Off On/Off On/Off 12:00 AM11:59 PM 22 digits 22 digits 22 digits 0000099999 On/Off 0000099999 005-120 sec 005-120 sec 0-3 0-9 On/Off 02-24 hrs 001-254 days 001-120 sec 001-255 min 02-24 hrs On/Off On/Off On/Off On/Off On/Off On/Off On/Off 1-4 21 Installation Instructions Document No. 466-1574 Table 18 Programmable Options Who Can Change: U1 - Utility Access Code 1; U2 - Utility Access Code 2; M - Master; U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 M U1 U2 M U1 U2 U1 U2 Option # Function Default Delete Range Installer Settings 28 29 30 31 32 33 34 35 36 37 38 39 No Delay from KeyChain Touchpad Panel Piezo Alarm Panic Alarms Day of Week 300 Baud Central Station Communications Audio Verification* Fail to Open Fail to Close Sensor Activated Light Lockout Start Time* Sensor Activated Light Lockout Stop Time* Auto Arm Siren Time Out Off On Off 0 On Off Off Off Off Off Off 04 min Off Off Off 0 110 Baud Off Off Off Off Off Off Siren never times out Off Off Low Off 9 Off Off Off Off Off Off Off Off Off On/Off On/Off On/Off 0-6 On/Off On/Off 12:00 AM 11:59 PM 12:00 AM 11:59 PM 12:00 AM 11:59 PM 12:00 AM 11:59 PM On/Off 01 - 30 minutes On/Off On/Off On/Off 22 digits 8 or 9 On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Trouble Beeps Chime Voice Speaker Level* Pager Phone Number Pager Phone Mod 3 Sensor Alarm Restoral Fire Shutdown - AVM* Audio Verification Mode* Panic Talk - AVM* Rechargeable Battery RF Jam Detect 24 Hour Battery Test High Level Status Hardwire Siren Supervision On Off On Off 9 Off Off Off Off Off Off Off Off Off U1 U2 U1 U2 M U1 U2 M U1 U2 M U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 U1 U2 22 * = Not Available with Basic Model Installation Instructions Document No. 466-1574 Wiring the Control Panel This section describes how to: · connect hardwire interior and exterior sirens (if being installed) · connect hardwire sensors · connect garage door opener module · connect the power transformer · connect the backup battery · connect a phone line Connecting a Hardwire Exterior Siren The following ITI exterior siren may be used with this Control Panel: · Hardwire Exterior Siren (13-046) Connecting Hardwire Interior Sirens The following ITI interior sirens may be used with this Control Panel: · · LD105 Siren (13-374) Phone Jack Siren (60-683) Turn option 53 on for siren supervision. When option 53 is on and a hardwire interior siren is not connected, a 47k ohm resistor (two 47k ohm resistors are shipped with the Control Panel) must be connected across the positive and negative terminals. If a 47k ohm resistor or a siren is not connected to the interior siren terminals, SYSTEM STATUS will say Module 2 failure. Wire sirens to be supervised by using a 4. 7k ohm EOL resistor, included with the siren. See figure 3 below for wiring connections. Note: Two 47k ohm resistors are included with the Control Panel. These should not be used for EOL resistors when wiring sirens. All inputs are Class II power-limited circuits. HARDWIRE INPUTS/SIREN Hardwire Hardwire Input 1 Hardwire Input 2 or or and Exterior Interior Power Siren Common Siren ­ ­ + Turn option 53 on for siren supervision. When option 53 is on and a hardwire exterior siren is not connected, a 47k ohm resistor (two 47k ohm resistors are shipped with the Control Panel) must be connected across the positive and negative terminals. If a 47k ohm resistor or a siren is not connected to the exterior siren terminals, SYSTEM STATUS will say Module 1 failure. Follow the siren installation instructions included with the siren for siren specific EOL resistor connections. See figure 2 below for a generalized wiring connection. HARDWIRE INPUTS/SIREN Hardwire Hardwire Input 1 Hardwire Input 2 or or and Exterior Interior Power Siren Common Siren ­ ­ + AC POWER 9 VAC BLACK RED 4. 7k OHM RESISTOR 47k OHM RESISTOR HARDWIRE EXTERIOR SIREN PART NO. 13-046 8988G20E. DS4 All inputs are Class II power-limited circuits. Supervised Exterior Siren Connections Connecting Hardwire Sensors This section shows how to wire hardwire sensors to the Control Panel. For more programming information on installing hardwire devices, "Programming Sensors" on page 27. Wire sensors to be supervised by using a 47k Ohm resistor (included with the Control Panel). [. . . ] Load Number: _____________ Acceptability Number: ____________ "AVIS: - L ´étiquette du ministère des Communications du Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme a certaines normes de protection, d ´ exploitation et de sécurité des réseaux de télécommunications. Le ministère n ´ assure toutefois pas que le matériel fonctionnera a la satisfaction de l ´ utilisateur. Avant d ´ installer ce matériel, l ´ utilisateur doit s ´ assurer qu´ il est permis de le raccorder aux installations de l ´ enterprise locale de télécommunication. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE INTERLOGIX SIMON 2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GE INTERLOGIX SIMON 2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.