User manual GENERAL ELECTRIC AGT05

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GENERAL ELECTRIC AGT05. We hope that this GENERAL ELECTRIC AGT05 user guide will be useful to you.


GENERAL ELECTRIC AGT05 : Download the complete user guide (3288 Ko)

Manual abstract: user guide GENERAL ELECTRIC AGT05

Detailed instructions for use are in the User's Guide.

[. . . ] This manual contains safety information to make you aware of the hazards and risks associated with this system and how to avoid them. We have made every effort to provide for a safe, streamlined and cost-effective installation. As each installation is unique, it is impossible to know of and advise of all conceivable procedures and methods by which installation might be achieved. We do not know all possible hazards and/or the results of each possible method or procedure. [. . . ] After opening the carton, carefully inspect the transfer switch components for any damage that may have occurred during shipment. If loss or damage is noted at time of delivery, have the person(s) making delivery note all damage on the freight bill and affix his signature under the consignor's memo of loss or damage. if loss or damage is noted after delivery , contact the carrier for claim procedures. The transfer switch enclosure must be installed with minimum NEMA 3R hardware for conduit connections. This can be done by placing washers between the enclosure and the mounting surface. NEVER install the switch or remote modules where any corrosive substance might drip onto the enclosure. Protect the switch at all times against excessive moisture, dust, dirt, lint, construction grit and corrosive vapors. It is best if the transfer switch is mounted near the utility meter, either inside or outside. The remote module can be located anywhere between the main distribution panel and its connected load, either inside or outside. Discuss layout suggestions/ changes with the owner before beginning the system installation process. Example of 240VAC heat pump load controlled by a dual low voltage remote module. Assign a different priority to each remote module for optimum operation. Despite the safe design of the system, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. To return to utility power, turn the utility service disconnect circuit breaker to the "ON" position. Utility Fail The generator senses when utility voltage is below 70 percent of nominal. Engine Warm-Up Time delay to allow for engine warm-up before transfer. Use jumper on transfer switch control board to select delay of 20 seconds or 50 seconds. Transfer Transfer from utility to generator supply occurs after voltage is above set levels. The transfer switch control board LED lights will change from green (utility) to red (generator) and the Symphony II status light will change blink status from Blink Blink_Pause_Blink Blink to Blink_Pause_Blink. Despite the safe design of the system, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. The Symphony II system can be tested under either utility power or generator power. Only one priority LED and associated remote module will be powered (ON) at a time during test mode. [. . . ] Generator is still running after utility power is restored Relay modules do not close after five minutes Minimum engine run time has not elapsed. Reset utility disconnect circuit breaker in transfer switch and wait five minutes (turn OFF breaker for ten seconds then turn it back ON). Status LED does not change wires are not connected between the illumination blinking pattern generator and transfer switch. Rewire remote module to opposite power line (L1 or L2) from that of problematic device. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GENERAL ELECTRIC AGT05




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GENERAL ELECTRIC AGT05 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.