User manual GRACO PROBLER P2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO PROBLER P2. We hope that this GRACO PROBLER P2 user guide will be useful to you.


GRACO PROBLER P2 : Download the complete user guide (2615 Ko)

Manual abstract: user guide GRACO PROBLER P2

Detailed instructions for use are in the User's Guide.

[. . . ] Probler P2 Delayed Air Purge / Dispense Counter Guardian Series Options For use with Probler P2 dispense gun. USER MANUAL S EQ UIP Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. M EN T IS PR TE O CTED B Y T HI U. S. A. PATENT PENDING Table Of Contents Warnings Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Section 1 Installation 1:1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 1:2 Model - Delayed Air Purge Standard Equipment GC1966 313286 DELAYED AIR PURGE ASSEMBLY USER MANUAL Model - Dispense Counter Standard Equipment GC1967 313286 DISPENSE COUNTER USER MANUAL 6 Section 1 - Installation: Specifications Sec. 1:3 DELAYED AIR PURGE FEATURES When the control box receives a signal from the gun air purge is shut off via the Air Purge control Valve (APCV); this valve is held in with the Delay Spool Valve (DSV). When the trigger is released the gun signal is cancelled to the DSV and the DSV counts down to reset mode. Using a small flat head screw driver, turn clockwise to increase delay time or counter-clockwise to decrease delay. To ensure the gun does not prematurely set up, the operator is responsible for recognizing the air purge delay time verses gel time of materials being processed with this equipment. The Red eye on the front panel indicates when the APCV is open, allowing air purge to the gun. The on/off switch will by-pass the signal air to the DSV, allowing the gun to be operated normally with out the delay action of air purge. DISPENSE COUNTER FEATURES The control box receives a signal when the gun trigger is activated, which activates the timer. Pneumatic drive systems use a 3-way check valve and receive signal from both upper and lower switches, making the timer a "stroke counter". Hydraulic drive systems use a single signal, typically to the lower signal switch, making the timer a "cycle counter". When the predetermined count is reached the timer activates the bimba cylinder in the back of the gun to overcome the trigger at the gun, the operator will need to recognize this "feel" of the trigger and release the trigger. When the gun trigger is released the signal air is cancelled to a delay spool valve (DSV) located in box assembly. The timer will reset to the set point and cancel the air to the actuation cylinder. The on/off switch will by-pass the counter signal allowing the system to operated independent of the counter. COUNTER CALCULATIONS Stroke output = . 021 gallon Cycle output = . 042 gallons 7 Section 1 - Installation: Equipment Assembly Sec. Remove o-ring from handle and install plug. 8 Section 1 - Installation: Equipment Assembly gun barrel. Reinstall side blocks after initial system start up is Section 1 - Installation: Equipment Assembly The box can be remote mounted to the operators discretion. Bracket kit GC1897 allows both the delay box and timer box to be mounted to Guardian series systems (refer to the options section of this manual to install the kit BEFORE beginning with step 1. ). Sec. Main air: Connect air hose from an accessory port on the Guardian air manifold, or line source to the air inlet regulator. 2. nps fitting on box assembly to main hose assembly air line (going to gun). 10 Section 1 - Installation: Equipment Assembly 3. 1:4 tubing to gun tubing to gun to elbow on back side of inlet regulator, run tubing with the main hose assembly up to gun, see gun installation. 4. port on bottom of box, run tubing with the main hose assembly up to gun, see gun installation. 11 Section 1 - Installation: Equipment Assembly Sec. Set air regulator to 100 psi (0. 7 MPa, 7. 0 bar); this is recommended operation pressure. The minimum recommended set point is 90 psi (0. 63 MPa, 6. 3 bar). 3. [. . . ] If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO PROBLER P2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO PROBLER P2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.