User manual GRACO PRODISPENSE 309301G

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO PRODISPENSE. We hope that this GRACO PRODISPENSE user guide will be useful to you.


GRACO PRODISPENSE 309301G: Download the complete user guide (2520 Ko)

Manual abstract: user guide GRACO PRODISPENSE309301G

Detailed instructions for use are in the User's Guide.

[. . . ] Instructions-Parts ProDispenseTM Not for use in explosive atmospheres. 309301G ENG Used to meter and dispense paints, coatings, solvents, water, and lubrication fluids. 244561 Electronic Preset Dispense System Important Safety Instructions Read all warnings and instructions in this manual. See page 4 for maximum working fluid pressure and system component information. Conforms to ANSI/UL standard 3121-1 CAN/CSA C22. 2 No 1010-1-92 Contents ProDispense System Components. . 39 40 40 41 42 43 46 48 50 52 54 56 62 64 65 66 67 68 69 Parts. [. . . ] Dispense fluid into a calibrated container (minimum 300 cc) by turning the Operator Station dispense switch to ON [and triggering the dispense valve]. Stop dispensing by [releasing the dispense valve trigger and] turning the dispense switch to AUTO. The amount the controller detected was dispensed appears on the screen in the Dispensed column. If the value in the column differs from the measured amount in the container, enter the measured value (in cc) in the Actual column. If nothing is entered in the Actual column, the K-factor remains unchanged. The controller will calculate the meter K-factor and display the new value in the K-factor column. Repeat the process for each of your fluid panels. 28 309301G Dispense Mode Dispense Mode Screen Navigation Dispense Mode Dispense Mode the alarms log. is used to dispense a fluid or recipe, check fluid dispense totals, and view RECIPE Fluid 1 Idle 005. 00 ltr 5. 00 ltr 5 0 Totals DISPENSE Fluid 2 Idle 050. 00 ltr 51. 00 ltr 5 +2 Alarms ID# Fluid 3 Idle 010. 10 ltr 10. 00 ltr 5 -1 Recipe Dispense screen Target Actual Tolerance % Difference % Run current screen 3 screen selections The name of the screen that is currently displayed is highlighted. The Operator Station dispense switch must be set to AUTO to dispense using the controller. AUTO Press the left or right arrow keys on the keypad to move through the screens. Press the up or down arrow keys to move through data fields on the Run screen. 309301G 29 Dispense Mode Run Run Screen Use the Run screen to dispense a recipe or individual fluids. The Run screen displays either Recipe Dispense or Fluid Dispense, depending on which Dispense Mode was selected in System setup. Idle, Dispense, and Alarm Status In each of the fluid columns, under the Fluid panel number, is a status line, which shows the status of the associated fluid panel. The three possible statuses are: Idle -- fluid panel is idle (not dispensing). Alarm -- controller has detected the fluid panel has an alarm condition. To view alarm information, press the right arrow key twice to move to Alarm screen. Refer to page 33. Status line Recipe Dispense RECIPE Fluid 1 Idle 005. 00 ltr 5. 00 ltr 5 0 Totals DISPENSE Fluid 2 Idle 050. 00 ltr 51. 00 ltr 5 +2 Alarms ID# Fluid 3 Idle 010. 10 ltr 10. 00 ltr 5 -1 Target Actual Tolerance % Difference % Run Recipe Dispense displays in the Run screen if "Recipe" is selected as the Dispense Mode. Recipe Dispense is used to dispense a set amount of fluid, typically from more than one fluid panel simultaneously. Place the dispense lines into the receptacle(s) you want to dispense into. Press the Start button on the Controller or on the Remote Operator Station to begin dispensing the recipe. Dispense Switch AUTO START DISPENSE AUTO ON 6. As the fluids dispense, their statuses on the screen change from Idle to Dispense and the amounts dispensed appear in the Actual row. Each fluid panel stops dispensing when its individual Target is reached. DISPENSE START ti1359a 30 309301G Dispense Mode Status line Fluid Dispense FLUID DISPENSE Fluid 1 Idle 005. 00 ltr 5. 00 ltr 5 0 Totals Fluid 2 Idle 050. 00 ltr 51. 00 ltr 5 +2 Alarms ID# Fluid 3 Idle 010. 10 ltr 10. 00 ltr 5 -1 Target Actual Tolerance % Difference % Run Fluid Dispense displays in the Run screen if "Fluid Station" is selected as the Dispense Mode. Fluid Dispense allows you to select a fluid panel and the amount to dispense on an individual basis. In the column for the fluid you want to dispense, type the desired amount of fluid in the Target field. Press the Start button on the Remote Operator Station to begin dispensing the fluid. STOP 5. [. . . ] . Accessories and Kits Part Number 239873 514037 198669 197902 198456 245248 244840 Description Printer kit Printer paper roll Printer cable 50 ft. (15. 24 m) Paint Shield For display screen, package of 10 Remote Station Extension Cable 20 ft. (6. 1 m) Software Upgrade Kit for Main PCB Includes main PCB chip with software upgrade, chip extractor, and grounding strap. Software Upgrade Kit for Display PCB Includes display PCB chip, chip extractor, and grounding strap. 309301G 73 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO PRODISPENSE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO PRODISPENSE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.