User manual GRACO SDM15

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO SDM15. We hope that this GRACO SDM15 user guide will be useful to you.


GRACO SDM15 : Download the complete user guide (2065 Ko)

You may also download the following manuals related to this product:

   GRACO SDM15 (1997 ko)
   GRACO SDM15 REV 10-2010 (2426 ko)
   GRACO SDM15 REV 10-2010 (2951 ko)
   GRACO SDM15 REV 10-2010 (2873 ko)

Manual abstract: user guide GRACO SDM15

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS SDM5 & SDM15 (Manual); SDP5 & SDP15 (Preset) Meters Not for use in explosive atmospheres. Maximum Working Pressure: 1500 psi (10 MPa, 103 bar) Maximum Working Pressure (50:50 antifreeze/water mix): 900 psi (6. 2 MPa, 62 bar) Maximum Flow Rate:14 gpm (53 lpm) 312865G ENG For metered dispense of oils and 50:50 antifreeze/water mix fluids. For professional use only. List of Models page 2 Preset Meter shown Important Safety Instructions Read all warnings and instructions in this manual. NOTICE This dispense valve is designed to dispense petroleum-based lubricants and antifreeze only. Do not dispense windshield washer solvent with this dispense valve. ti11821 US Patent No: D594, 490S India Patent No: 219652 Korea Patent No: 30-555779 Taiwan Patent No: D130836 Models Models SDM5 Manual Dispense Electronic Meters Model Number 255348 255349 255350 255802 255803 Swivel 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) Extension Description Flexible Extension Gear Lube Extension Rigid Extension Rigid Extension Flexible Extension Nozzle Automatic, non-drip, quick close None-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Fluid Type Oil Gear Lube Oil Anti-freeze Anti-freeze SDM15 Manual Dispense Electronic Meters Model Number 255800 255801 255836 255837 Swivel 3/4" npt(f) 3/4" npt(f) 1/2" npt(f) 1/2 npt(f) Extension Description Rigid Extension Flexible Extension Rigid Extension Flexible Extension Nozzle Automatic, non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Fluid Type Oil Oil Oil Oil SDP5 Preset Dispense Electronic Meters Model Number 255200 255351 255352 255355 255356 Swivel 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) 1/2" npt(f) Extension Description Rigid Extension Flexible Extension Gear Lube Extension Rigid Extension Flexible Extension Nozzle Automatic, non-drip, quick close Automatic, Non-drip, quick close Non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Fluid Type Oil Oil Gear Lube Anti-freeze Anti-freeze 2 312865G Models SDP15 Preset Dispense Electronic Meters Model Number 255353 255354 256838 256839 Swivel 3/4" npt(f) 3/4" npt(f) 1/2" npt(f) 1/2" npt(f) Extension Description Rigid Extension Flexible Extension Rigid Extension Flexible Extension Nozzle Automatic, non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Automatic, non-drip, quick close Fluid Type Oil Oil OIl Oil 312865G 3 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. [. . . ] Use the RIGHT ARROW button to skip fields or if you do not need to use all 11 spaces, to return curser to the Wrench icon. After 11th character has been confirmed, curser automatically moves to Wrench icon (D). Use the center, ENTER button, to return to the Main Setup Screen. FIG. Language field/button: When curser is over this button, each time UP or DOWN arrow is pressed, the name of the Language displayed on the button changes. Use the LEFT or RIGHT ARROW to move the curser to the Language field/button (T). When the name of your language is displayed on the field/button (T), press the center ENTER button to confirm selection. The selected language is then displayed on screen in Language field (S). After you press the center, ENTER button, the name on the field/button will also change from "SPANISH" to "EPANOL" and will appear this way on both the Language button (T) and in the Language field (S) on the screen. 4. When you have finished making changes, use the LEFT OR RIGHT ARROW button to move curser over Wrench icon. Press center, ENTER button, to return to Main Setup Screen. 312865G 17 Dispensing Fluid and Operation Mode Screens Dispensing Fluid and Operation Mode Screens FIRE HAZARD: Conductive metal surfaces on the meter must not make contact with any positively charged metal surface, including (but not limited to), the starter solenoid terminal, alternator terminal or battery terminal. If you are in the Setup Mode, to display the Operation Mode Screens use the UP or DOWN ARROW button to select HOME from the list. Press the Center ENTER button to display the Operation Mode Home Screen shown in FIG. A complete description of the Setup Mode Screens begins on page 11. Home Screen (FIG. 18) All Meters Manual Meters D Preset Meters A D MOBIL1 5W-20 MOBIL1 5W-20 A MANUAL TOTALS C B B C MANUAL PRESET TOTALS ti12184a ti12175a FIG. Screen Identifier Icon: House displays when user is on the Home Screen. Operation Screen choices include: Manual Meters · · MANUAL TOTALS 1. Press center, ENTER button to confirm selection and display the screen. Data is input on Setup Mode Banner Screen, page 17. Preset Meters · · · MANUAL PRESET TOTALS 18 312865G Dispensing Fluid and Operation Mode Screens Manual Dispense (FIG. 19) All Meters D To dispense in Manual Mode: If display was asleep, press any button to wake it up. MOBIL1 5W-20 Preset shown MOBIL1 5W-20 QTS H 10. 56 G E F ti12178a MANUAL PRESET TOTALS ti12180a FIG. Unit of Measurement: Identifies unit of measurement, pint, quart, gallon or liter. Press center, ENTER button to confirm selection. The Manual Dispense screen (FIG. If using a Preset meter, trigger may be locked during the dispense. Fluid flows. The amount displayed counts up from zero or from the previously dispensed amount (FIG. [. . . ] At 2. 5 gpm (9. 5 lpm), at 70°F (21°C), with 10-weight oil and 1 gallon dispensed. May require calibration; out-of-box accuracy is +/- 1. 25 percent. 312865G 41 Graco Extended Metered Dispense Valve Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. Graco will, for a period of five (5) years from the date of sale, repair or replace any non-electronic part of the equipment determined by Graco to be defective. Graco will also for a period of three (3) years from the date of sale, repair, or replace any meter electronic components determined by Graco to be defective. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO SDM15




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO SDM15 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.