User manual HAIER HSU-10HA03(B)

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-10HA03(B). We hope that this HAIER HSU-10HA03(B) user guide will be useful to you.


HAIER HSU-10HA03(B) : Download the complete user guide (886 Ko)

Manual abstract: user guide HAIER HSU-10HA03(B)

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT AIR CONDITIONER OPERATION MANUAL AS102AMARA AU102ACARA (HSU-10HA03(DB)) AS102ALARA AU102ACARA (HSU-10H03(DB)) AS122AYARA AU122ACARA (HSU-12HA03(DB)) AS122AVARA AU122ACARA (HSU-12H03(DB)) Digital DC Variable Frequency Healthy Split Air Conditioner Please read this manual carefully before use. No. 0010540438 I Contents Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Name of Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation Hints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 Notes for Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18 Trouble Shooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-21 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-30 Installation Check and Trial Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use. Unplug the air conditioner in order to avoid the risk of child entrapment. [. . . ] If the remote controller cannot run normally or doesn't work at all, use a sharp pointed item to press the reset button (with the mark ). Liquid hose Gas hose 3. Put on nut 4. Expand Hose A Hose dia. 6. 35 mm(1/4") 9. 52 mm(3/8") 12. 7 mm(1/2") Refrigeration Oil Connector Nut Piping Connection Hose Expander 1. Connecting Method To ensure the efficiency, the pipe should be as short as possible. Spanner To bend a pipe, five the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to the Drawing. Correct Be careful not to let foreign matters, such as sands enter the pipe. Tilting Fastening Torque Liquid pipe 6. 35mm(1/4") 18 N. m Gas Pipe 9. 52mm(3/8") 42 N. m Gas Pipe 12. 7mm(1/2") 50 N. m 26 + /- as illustrated. Spanner Not Correct cracks on expanded mouth burr incomplete too long 7 Operation Installation 1. Drill through Wall Small Hints: Remove the batteries in case the unit won't be in use for a long period. The remote controller will be self-checked after loading the new batteries by displaying all the symbols and resume working very soon. 4. After turning on the air conditioner, set to the desired mode: The remote controller displays the mode selected, the power light on the indoor unit lights up. Install Outdoor Unit is displayed and ion the power or healthy operation indicator turns from orange color to green. Now the air conditioner is operating the healthy function, meanwhile the anion generator in the indoor unit begins to release anion to clean the air and eliminate dust. Cancel Healthy Operation: Press the button Health again to stop the display, then the healthy operation stops. Notes: When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. Brief Introduction to Health Operation The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of posion and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. Check Drainage TEMP ON/OFF SWING FAN POWER RESET HEALTH 3 2 10. Wind up Pipes The step 4 and step 5 above can be adjusted according to the practical situation. This procedure is a reference to the installation person and customer, it can be adjusted according to the practical situation. 8 25 Installation To enable the air conditioner to work well, please install it as required by this manual. height difference between the indoor unit and outdoor unit is 7 meters for AS122 AVARA/AU122 ACARA(HSU-12H03(DB)) AS122AYARA/AU122ACARA(HSU-12HA03(DB)) and 5 meters for AS102ALARA/AU102ACARA (HSU-10H03(DB)) AS102AMARA/AU102ACARA(HSU-10HA03(DB)). After installation, please operate the air conditioner as per this manual. Electrical Requirements A specialized power supply wire, which shall be installed by a competent person as per the rules of the national standard. And the socket must have an earth to make the air conditioner be grounded through the power supply socket. [. . . ] After electric wiring , the air conditioner shall be electrified to check for electric leakage. Trouble Shooting The followings are not malfunction: Water flowing sound is heard. When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped. It is the flowing sound of the refrigerant, and it is not a trouble. Hu Hua a Cracking sound is heard. This is caused by heat expansion or contraction of plastics. The smell results from residents of tobacco smoke or cosmetics stuck inside of unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-10HA03(B)




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-10HA03(B) will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.