User manual HAIER HSU-12H03(BP)1
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HSU-12H03(BP)1. We hope that this HAIER HSU-12H03(BP)1 user guide will be useful to you.
Manual abstract: user guide HAIER HSU-12H03(BP)1
Detailed instructions for use are in the User's Guide.
[. . . ] Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver Air filter Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually. ) A beeping sound is generated when a signal from remote controller is received.
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Operation mode indicator
Lights up during compressor running.
Outdoor Unit
OUTLET INLET
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
2
Parts and Functions
Operation
Buttons and display of the remote controller.
1. MODE
Used to select COOL, DRY and HEAT operation
1 2 3 4
ON/OFF TEMP
5 6 7 8 9
10
AUTO
HI
MED
LO
11 17
MODE SET
12
FAN TIMER
18
Used for unit start and stop.
13 14 15
POWER/SOFT
19
SWING CLOCK
13. [. . . ] For each press, fan speed changes as follows:
LOCK RESET
AUTO
LO
MED
HI
Unit runs at the speed displayed on LCD. setting, unit will run intermittently at LO speed regardless of FAN setting.
o
Hints
On cooling only unit, heating mode is not available. When starting it next time, just press ON/OFF button and unit will run in previous status.
5
Operation
(5) Air flow direction adjustment
After operation mode is selected, vertical flap will open automatically according to the mode. COOL About 10
o
HEAT About 60o
Up and down (Use remote controller)
Left and right air flow adjustment Press SWING button, vertical flap will move within (manual)
the range shown in the Fig. Vertical flap will resume original position one hour later in order to avoid condensate water. About 10o COOL About 45o HEAT About 60o Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig.
Cautions:
It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
Cautions:
When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.
(6) Unit stop
Press ON/OFF button. Vertical flap closes automatically.
Cautions:
Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. It is harmful to your health in summer to go frequently in and out of places where temp. More than this, unit's load can be reduced and power consumption cut down as well. in COOL mode.
6
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use this funciton.
ON/OFF TEMP
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed, display changes as follows:
BLANK POWER SOFT
MODE
SET
FAN
TIMER
Stop the display at
SWING
CLOCK
In POWER operation status:
In COOL mode, when room temperature is lower 4 C than temperature setting , compressor runs high-frequency for 15 min then returns to original status setting. In HEAT mode, when room temperature is higher 6 C than temperature setting , compressor runs high-frequency for 15 min then returns to original status setting.
o o
LOCK
POWER/SOFT
RESET
To cancel POWER operation
Press POWER/SOFT button twice , POWER/SOFT disappears.
SOFT Operation
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed, display changes as follows:
BLANK POWER SOFT
Stop the display at In SOFT operation mode, fan speed automatically takes"LOW"
To cancel POWER operation
Press POWER/SOFT button once , POWER/SOFT disappears. Hints: During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
7
Operation
TIMER Operation
Set Clock correctly before starting Timer operation
You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1)After unit start, select your desired operation mode. Power indicator on indoor unit lights up.
(2)TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
blank
OFF
ON
ON/OFF
TEMP
TIMER OFF TIMER ON
Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash.
MODE
1
SET
3
FAN
4
TIMER
(3)Timer setting
Press HOUR / button. (TIMER ON or TIMER OFF).
3
SWING
2
CLOCK
POWER/SOFT
LOCK
RESET
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Notice
Hints
Once the remote controller set the timer, the period is memorized. [. . . ] Cleaning of the air filter.
Once every two weeks
Proper temperature
Closing of doors and windows during operation
Effective use of the timer.
Curtains or blinds for windows
Avoid time-wasteful operation
Never fail to observe the followings
Do not sprinkle water over the unit. Do not block the inlet or outlet.
Do not pull power plug.
Do not use for other purposes.
Such as food preservation plant cultivation or animal breeding.
12
Trouble shooting
Before asking for service, check the following first.
Phenomenon The system does not restart immediately. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. [. . . ]