[. . . ] conditioner that carry refrigerant by piercing or performating the air conditioner's tubes Consult your local authorities for the name with sharp or pointed items, crushing or and address of the waste materials collecting twisting any tubes, or scraping the coatings centers and waste paper disposal services off the surfaces. out and gets into eyes, it may result in serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. [. . . ] same time.
CAUTION
PROHIBITION Do not install the unit near a fireplace or other heating apparatus.
STRICT ENFORCEMENT Check good condition of the installation stand
PROHIBITION Do not pour water onto the unit for cleaning
PROHIBITION Do not place animals or plants in the direct path of the air flow
PROHIBITION Do not place any objects on or climb on the unit.
PROHIBITION Do not place flower vase or water containers on the top of the unit.
PROHIBITION
PROHIBITION
PROHIBITION
4
Parts and Functions
Indoor Unit
Display board Inlet Air Purifying Filter (inside) Inlet grille Horizontal flap (adjust up and down air flow. Don't adjust it manually) Anion generator (inside) Vertical blade (adjust left and right air flow) Outlet Air filter(inside) Power plug
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Outdoor Unit
HSU-09HEA03 HSU-12HA03(B)
OUTLET INLET
HSU-18HEA13(T3) HSU-18HEA03(T3) HSU-12HEA03 HSU-18LEA13(T3) HSU-18LEA03(T3)
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
5
Parts and Functions
Remote controller
1 2 5 3
23 24 13 18
HEALTH ON/OFF
Display board
10
6 7 8 9 4
11
FAN
MODE
SWING TIMER CLOCK SET
LOCK
15 20 14
12 21 19 17
SLEEP
RESET
16 22
1. Operation mode display
O Operation mode AUT COOL DRY HEAT FAN
Remote controller
Display board
2. SIGNAL SENDING 7. TIMER OFF display
AUTO
LO
MED
HI
Clock set
23 26 1 789 1 8. Ambient temp. display When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
25
1
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal. 6
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. r When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover:
HEA LTH ON/ OFF FAN DE MO
ING SW
ER TIM
CLO
CK
SET
K LOC
EP SLE
RES
ET
Slightly press " Load the battery:
" and push down the cover.
Be sure that the loading is in line with the" + "/"-" pole request as illustrated. Put on the cover again Confirmation indicator: In disorderation, reload the batteries or load the new batteries after 6 mins.
Note:
Use two new same-typed batteries when loading. After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
further 3 hours then stops. setting so that room temperature won't be too high for your sleep.
Temp. setting 1 hr 1 hr
O
Use of SLEEP function
Unit stop
Decreases 2 C
O
ON/OFF
Decreases 2 C 3 hrs Rises 1 C 3 hrs SLEEP SLEEP operation stops operation starts In HEAT mode
O
FAN
MODE
SWING
TIMER CLOCK SET
LOCK
SLEEP
RESET
Operation Mode
1. setting so that room temperature won't be too Iow for your sleep. .
SLEEP operation stops SLEEP operation starts Approx. 6hrs 1 hr 1 hr Rises 1 C
O O
4. When quiet sleeping function is set to 8 hours , the quiet sleeping time can not be adjusted. When TIMER function is set, the quiet sleeping function can't be set up . After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time , either of their operation time is ended first , the unit will stop automatically, and the other mode will be cancelled.
The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.
3. In AUTO mode
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running. press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds. 13
Rises1 C
Unit stop Temp. setting In COOL, DRY mode
1 hours after SLEEP mode starts, temp will become 2OC lower than temp. setting. In HEAT mode
Note to the power failure resume:
Operation
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost. [. . . ] The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit.
5. Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months.
The bacteria-killing medium air purifying filter will be used for a long time, no need for replacement. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced.
17
Trouble shooting
Before asking for service, check the following first.
Phenomenon The system does not restart immediately. [. . . ]