User manual HAWKE MEJB 1 ASSEMBLY

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAWKE MEJB 1. We hope that this HAWKE MEJB 1 user guide will be useful to you.


HAWKE MEJB 1 ASSEMBLY: Download the complete user guide (58 Ko)

Manual abstract: user guide HAWKE MEJB 1ASSEMBLY

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly Instructions for: EJB 1& EJB 2 Junction Boxes MEJB 1 & MEJB 2 Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Terminal Box CAT II 2G for use in Zone 1. Service Temperature EJB 1 & 2 -60°C to +80°C MEJB 1 & 2 -60°C to +80°C Minimum Installation Temperature: -5°C International Assembly Instructions AI 290 / Issue A - 06/10 Certification Details Box Type: EJB 1 & 2 and MEJB 1 & 2 Exe II/ExtD A21 IP66 Baseefa No: 08ATEX0208X II 2 GD T** T* Tamb *** IP66 IEC Ex No: BAS08. 0065X EJB 1 = 148 / EJB 2 = 178 EJB 1 = 126 / EJB 2 = 156 EJB 1 = 126 / EJB 2 = 156 ø1 0 Adjustable Terminal Insulation Clamp 0. 5 ± 0. 5mm Fixed Terminal Clamp EJB 1 = 81. 5 / EJB 2 = 91. 5 W = Maximum Dissipated Wattage N = No. of Terminals Fitted F = Combined Terminal Resistance I = Maximum Current I = Sqrt (W / N x F) W = N x F x I² N = W / F x I² Note: Combined Terminal Resistance = Resistance of Maximum Conductor Length (see BS 6360 and table below) + Terminal Resistance Maximum Power Dissipation (Watts) Box Type T* T6 T** T*** T* T** T*** T* T** T*** T* T** T*** T* T** T*** T* 80°C -40/+40°C T6 80°C -40/+55°C T6 80°C -40/+65°C T5 80°C -40/+40°C T5 80°C -40/+55°C T5 Max. [. . . ] b) Where other certified components are part of the assembly, the user must take account of any limitations listed on relevant certificates. c) If an optional Breather/Drain as listed on the enclosure certificate is fitted the enclosure must be sited such that the Breather/Drain is pointing vertically downwards from the bottom of the box, and the IP rating of the selected Breather/Drain shall match the IP rating of the enclosure. Where the customer drills cable entries they must be installed in accordance with the component certificates Baseefa 08ATEX0207U or IEC Ex BAS 08. 0064U and enclosure limitations, these specify a maximum clearance on the entry thread of 0. 7mm for plain holes and where adjacent cable entries are installed sufficient clearance must be maintained to allow for the fitting of sealing/retaining washers and the rotation of the cable gland hexagons, and leave a minimum of material between adjacent holes inline with the above certificate number(s). e) All unused entry apertures must be sealed using a stopping plug as listed on the enclosure certificate and also the IP rating of the junction box shall be maintained for the zone of use. f ) The apparatus must not be modified in anyway without reference to Hawke, as this will invalidate the certification, except for EI d) and e) and TW j) and k). g) When document pocket is fixed to the inside of the lid, care must be taken by installer / end-user to prevent static build-up i. e. TERMINAL WIRING (TW) a) All wiring must be carried out in accordance with the relevant code of practice and/or instructions e. g. b) The voltage and current and maximum dissipated power shown on the label must not be exceeded. c) When used as a general purpose junction box or marshalling box the circuits carrying currents 1A shall be individually protected against over current such that the protective device operates effectively at no more than 1. 45 times the current carrying capacity of the smallest conductor used in that circuit. d) Where a major portion of the terminals are carrying maximum rate current the temperature at the branching point of the conductors may exceed 70°C. Under these circumstances the installer must ensure that the limiting temperature for the cable insulation used is acceptable e. g. e) Not more than one single or multiple stranded lead shall be connected into either side of the terminals, unless the relevant component certificate allows more, or unless the multiple conductors have been previously joined in a suitable manner (for example with an insulated crimped boot lace ferrule, mounted in a vertical position) such that they form a single cohesive item for insertion into the terminal way. The installer must ensure that the conditions of use for the terminals outlined are complied with. h) The installer shall ensure creepage and clearance distances are not reduced, especially between intrinsically safe (is) and non-is circuits (e. g. i) The use of any cross connection devices between adjacent terminal ways shall be in accordance with the requirements of the relevant component certificate listed on Drg. j) Use of the terminal box at ambient temperatures below ­20°C is dependant upon the minimum service temperature of the terminals. [. . . ] Amps Combined Terminal Resistance (Ohms) Insulation Terminal Stripping Tightening Torque Length (Nm) (mm) WDU2. 5 WDU2. 5 WDU4 WDU6 WDU10 SAKK4 ** SAKK10 ** BK6 MK6/6 0. 5 0. 5 0. 5 0. 5 1. 5 0. 5 0. 5 1. 0 1. 0 2. 5 2. 5 4. 0 6. 0 10. 0 6. 0 10. 0 4. 0 6. 0 420 550 690 550 550 275 275 275 420 12 12 10 7 6 7 5 1 1 15 15 20 11 9 20 35 21 26 9 9 8 6 5 7 5 1 1 17 17 22 29 40 20 35 - 0. 001731 0. 001701 0. 001163 0. 000850 0. 000539 0. 001193 0. 000419 0. 000920 0. 000700 10 10 10 12 12 9 9 8 9 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 0. 5 - 1. 0 2. 0 - 2. 4 0. 5 - 0. 7 1. 2 - 2. 0 Note: Terminals listed (with the exception of **) are only suitable for a minimum operating temperature of -50°C SAKK terminals are suitable for -60°C EJB 2 Terminal Capacity Data Terminal Type Conductor Size mm² Min Max Max. Volts Maximum Physical Reduced Terminal Content Terminal Content at Maximum Terminal Amps Term. Amps Combined Terminal Resistance (Ohms) Insulation Stripping Length (mm) Terminal Tightening Torque (Nm) WDU2. 5N WDU2. 5 WDU4 WDU6 WDU10 WDU16 SAKK4 ** SAKK10 ** BK6 MK6/6 0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 0. 5 0. 5 1. 0 1. 0 2. 5 2. 5 4. 0 6. 0 10. 0 16. 0 6. 0 10. 0 4. 0 6. 0 420 550 690 550 550 690 275 275 275 420 18 18 15 11 9 7 11 8 1 1 13 13 18 24 34 47 20 35 21 26 11 11 10 8 6 5 11 8 1 1 17 17 22 29 40 53 20 35 21 26 0. 002049 0. 002019 0. 001361 0. 000982 0. 000617 0. 000412 0. 001391 0. 000497 0. 001052 0. 000832 10 10 10 12 12 16 9 9 8 9 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 2. 0 - 4. 0 0. 5 - 1. 0 2. 0 - 2. 4 0. 5 - 0. 7 1. 2 - 2. 0 Note: Terminals listed (with the exception of **) are only suitable for a minimum operating temperature of -50°C SAKK terminals are suitable for -60°C AI 290 - Issue A / Page 3 of 3 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE MEJB 1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE MEJB 1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.