User manual HAWKE MS4 ASSEMBLY AI 266 ISSUE K 03-09

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAWKE MS4. We hope that this HAWKE MS4 user guide will be useful to you.


HAWKE MS4 ASSEMBLY AI 266 ISSUE K 03-09: Download the complete user guide (98 Ko)

Manual abstract: user guide HAWKE MS4ASSEMBLY AI 266 ISSUE K 03-09

Detailed instructions for use are in the User's Guide.

[. . . ] of Terminals Fitted F = Combined Terminal Resistance I = Maximum Current I = Sqrt (W / N x F) W = N x F x I² N = W / F x I² Note: Combined Terminal Resistance = Resistance of Maximum Conductor Length (see BS 6360 and table below) + Terminal Resistance Max. Cable Length Per Terminal (M) T6 80°C -40/+40°C T6 80°C -40/+55°C T6 80°C -40/+65°C T5 80°C -40/+40°C T5 80°C -40/+55°C T5 80°C -40/+65°C T* T** T*** T* T** T*** T* T** T*** T* T** T*** T* T** T*** T* T** T*** Maximum Power Dissipation (Watts) Box Type Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Size 7 Size 8 Size 9 13. 95 18. 15 23. 70 29. 95 32. 85 40. 00 52. 00 65. 00 79. 35 8. 7 11. 3 14. 8 18. 7 20. 5 25. 0 23. 5 40. 6 49. 5 5. 2 6. 8 8. 8 11. 2 12. 3 15. 0 19. 5 24. 3 29. 7 19. 1 24. 9 32. 5 41. 1 45. 1 55. 0 71. 5 89. 3 109. 1 13. 95 18. 15 23. 70 29. 95 32. 85 40. 00 52. 00 65. 00 79. 35 10. 4 13. 6 17. 7 22. 4 24. 6 30. 0 39. 0 48. 7 59. 5 0. 307 0. 425 0. 515 0. 579 0. 662 0. 792 0. 945 1. 090 1. 238 AI 266 - Issue K / Page 1 of 6 Sales (UK): 0870 606 0105 Sales: +44 (0) 161 830 6698 Technical (UK): 0870 458 9358 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com Connection Solutions Hawke International is a division of Hubbell Ltd. Registered Office: Mitre House, 160 Aldersgate Street, London EC1A 4DD. [. . . ] Where the customer drills cable entries they must be installed in accordance with the component certificates BAS01ATEX2105U, Baseefa 08ATEX0207U or IEC Ex BAS 08. 0064U and enclosure limitations, these specify a maximum clearance on the entry thread of 0. 7mm for plain holes and where adjacent cable entries are installed sufficient clearance must be maintained to allow for the fitting of sealing/retaining washers and the rotation of the cable gland hexagons, and leave a minimum of material between adjacent holes inline with the above certificate number(s). e) All unused entry apertures must be sealed using a stopping plug as listed on the enclosure certificate and also the IP rating of the junction box shall be maintained for the zone of use. f) The apparatus must not be modified in anyway without reference to Hawke, as this will invalidate the certification, except for EI d) and e) and TW j) and k). TERMINAL WIRING (TW) a) All wiring must be carried out in accordance with the relevant code of practice and/or instructions e. g. IEC/EN 60079-14, IEC 60079-14, EN61241-0, EN 61241-1, IEC 61241-0 and IEC 61241-1. b) The voltage and current and maximum dissipated power shown on the label must not be exceeded. c) When used as a general purpose junction box or marshalling box the circuits carrying currents 1A shall be individually protected against over current such that the protective device operates effectively at no more than 1. 45 times the current carrying capacity of the smallest conductor used in that circuit. d) Where a major portion of the terminals are carrying maximum rate current the temperature at the branching point of the conductors may exceed 70°C. Under these circumstances the installer must ensure that the limiting temperature for the cable insulation used is acceptable e. g. e) Not more than one single or multiple stranded lead shall be connected into either side of the terminals, unless the relevant component certificate allows more, or unless the multiple conductors have been previously joined in a suitable manner (for example with an insulated crimped boot lace ferrule, mounted in a vertical position) such that they form a single cohesive item for insertion into the terminal way. The installer must ensure that the conditions of use for the terminals outlined are complied with. h) The installer shall ensure creepage and clearance distances are not reduced, especially between intrinsically safe (is) and non-is circuits (e. g. i) The use of any cross connection devices between adjacent terminal ways shall be in accordance with the requirements of the relevant component certificate listed on Drg. j) Use of the terminal box at ambient temperatures below ­20°C is dependant upon the minimum service temperature of the terminals. k) When connecting a terminal with a conductor that is below the maximum cross section area shown for the terminal, then the maximum amps / pole must be reduced in line with the maximum amps indicated for a terminal equivalent to the conductor size being fitted e. g. for a terminal that can take a maximum conductor size of 10mm² at 40 Amps, but is fitted with a 4mm² conductor then the current shall be reduced to a maximum a 22 Amps, or the rating on the junction box lid label (whichever is the lowest). [. . . ] Amps Combined Terminal Resistance (Ohms) Insulation Stripping Length (mm) Terminal Tightening Torque (Nm) WDU2. 5N WDU2. 5 WDU4 WDU6 WDU10 WDU16 WDU35 WDU70N WFF35 * SAKK4 ** SAKK10 ** 0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 2. 5 10 2. 5 2. 5 2. 5 4. 0 6. 0 10. 0 16. 0 35. 0 70. 0 35. 0 420 550 690 550 550 690 690 690 1100 275 275 112 112 94 72 56 48 36 14 11 72 50 7 7 9 13 19 25 41 90 76 11 21 19 19 17 15 12 11 8 6 11 21 18 17 17 22 29 40 53 87 134 76 20 35 0. 004176 0. 004146 0. 002684 0. 001866 0. 001142 0. 007420 0. 000370 0. 000198 0. 000310 0. 002710 0. 001020 10 10 10 12 12 16 16 22 Bolt Size M6 16 22 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 2. 0 - 4. 0 4. 0 - 5. 0 8. 0 - 12. 0 3. 0 - 6. 0 0. 5 - 1. 0 1. 2 - 2. 4 0. 5 6. 0 0. 5 10. 0 * Complete with cover Note: Terminals listed (with the exception of **) are only suitable for a minimum operating temperature of -50°C SAKK terminals are suitable for -60°C AI 266 - Issue K / Page 3 of 6 Size 4 Terminal Capacity Data Terminal Type Conductor Size mm² Min Max Max. Amps Combined Terminal Resistance (Ohms) Insulation Stripping Length (mm) Terminal Tightening Torque (Nm) WDU2. 5N WDU2. 5 WDU4 WDU6 WDU10 WDU16 WDU35 WDU70N WDU70/95 WDU70/95 WDU120/150 WDU120/150 WFF35 * WFF70 * WFF120 * WFF185 * WFF300 * SAKK4 ** SAKK10 ** 0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 2. 5 10. 0 16. 0 16. 0 35. 0 35. 0 2. 5 2. 5 6. 0 10. 0 25. 0 0. 5 0. 5 2. 5 2. 5 4. 0 6. 0 10. 0 16. 0 35. 0 70. 0 70. 0 95. 0 120. 0 150. 0 35. 0 70. 0 120. 0 185. 0 300. 0 6. 0 10. 0 420 550 690 550 550 690 690 690 690 690 1100 1100 1100 1100 1100 1100 1100 275 275 380 380 320 240 200 160 120 50 19 19 16 16 38 16 12 9 9 240 170 4 4 5 7 11 15 25 54 86 97 114 120 48 100 152 212 255 6 12 22 22 20 17 15 13 10 8 7 9 7 8 15 12 10 7 5 25 21 17 17 22 29 40 53 87 134 134 134 162 162 76 116 162 234 316 20 35 0. 006229 0. 006199 0. 003961 0. 002719 0. 001649 0. 001061 0. 000515 0. 000272 0. 000282 0. 000223 0. 000191 0. 000168 0. 000455 0. 000242 0. 000141 0. 000098 0. 000068 0. 003990 0. 001530 10 10 10 12 12 16 18 22 30 30 35 35 Bolt Size M6 Bolt Size M8 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 2. 0 - 4. 0 4. 0 - 5. 0 8. 0 - 12. 0 6. 0 - 12. 0 6. 0 - 12. 0 10. 0 - 20. 0 10. 0 - 20. 0 3. 0 - 6. 0 6. 0 - 12. 0 Bolt Size M10 10. 0- 20. 0 Bolt Size M12 14. 0 - 31. 0 Bolt Size M16 25. 0 - 60. 0 10 12 0. 5 - 1. 0 1. 2 - 2. 4 * Complete with cover Note: Terminals listed (with the exception of **) are only suitable for a minimum operating temperature of -50°C SAKK terminals are suitable for -60°C Size 7 Terminal Capacity Data Terminal Type Conductor Size mm² Min Max Max. Amps Combined Terminal Resistance (Ohms) Insulation Stripping Length (mm) Terminal Tightening Torque (Nm) WDU2. 5N WDU2. 5 WDU4 WDU6 WDU10 WDU16 WDU35 WDU70N WDU70/95 WDU70/95 WDU120/150 WDU120/150 WFF35 * WFF70 * WFF120 * WFF185 * WFF300 * SAKK4 ** SAKK10 ** 0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 2. 5 10. 0 16. 0 16. 0 35. 0 35. 0 2. 5 2. 5 6. 0 10. 0 25. 0 0. 5 0. 5 2. 5 2. 5 4. 0 6. 0 10. 0 16. 0 35. 0 70. 0 70. 0 95. 0 120. 0 150. 0 35. 0 70. 0 120. 0 185. 0 300. 0 6. 0 10. 0 420 550 690 550 550 690 690 690 690 690 1100 1100 1100 1100 1100 1100 1100 275 275 600 600 515 380 300 250 190 93 23 23 20 20 46 40 15 11 11 380 268 3 3 4 6 9 12 21 42 83 94 110 117 45 67 145 203 227 5 10 24 24 23 19 16 14 11 9 8 11 9 10 16 13 11 8 6 27 23 17 17 22 29 40 53 87 134 134 134 162 162 76 116 162 234 316 20 35 0. 007362 0. 007332 0. 004666 0. 003191 0. 001929 0. 001237 0. 000595 0. 000313 0. 000323 0. 000252 0. 000215 0. 000187 0. 000535 0. 000283 0. 000165 0. 000114 0. 000077 0. 004696 0. 001809 10 10 10 12 12 16 18 22 30 30 35 35 Bolt Size M6 Bolt Size M8 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 2. 0 - 4. 0 4. 0 - 5. 0 8. 0 - 12. 0 6. 0 - 12. 0 6. 0 - 12. 0 10. 0 - 20. 0 10. 0 - 20. 0 3. 0 - 6. 0 6. 0 - 12. 0 Bolt Size M10 10. 0- 20. 0 Bolt Size M12 14. 0 - 31. 0 Bolt Size M16 25. 0 - 60. 0 10 12 0. 5 - 1. 0 1. 2 - 2. 4 * Complete with cover Note: Terminals listed (with the exception of **) are only suitable for a minimum operating temperature of -50°C SAKK terminals are suitable for -60°C AI 266 - Issue K / Page 5 of 6 Size 8 Terminal Capacity Data Terminal Type Conductor Size mm² Min Max Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE MS4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE MS4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.