User manual ICOM IC-F12

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-F12. We hope that this ICOM IC-F12 user guide will be useful to you.


ICOM IC-F12 : Download the complete user guide (473 Ko)

You may also download the following manuals related to this product:

   ICOM IC-F12 BROCHURE (933 ko)
   ICOM IC-F12 BROCHURE (173 ko)

Manual abstract: user guide ICOM IC-F12

Detailed instructions for use are in the User's Guide.

[. . . ] · 16CH version: Turn the selector knob to select the programmed operating channel. w VOLUME CONTROL [OFF/VOL] Turns power ON and adjusts the audio level. e DEALER-PROGRAMMABLE KEY [Upper] Can be programmed for one of several functions by your Icom dealer. t DEALER-PROGRAMMABLE KEY [Lower] Can be programmed for one of several functions by your Icom dealer. [. . . ] If you want to charge the battery pack more than 300 times, the following points should be observed: · Avoid overcharging­batteries must be removed from the charger to stop charging. Batteries should not be charged for more than 15 hours after the LED indicator turns green. · Use the battery until it becomes almost completely exhausted under normal conditions. D Battery pack life When the operating period becomes extremely short even after charging the battery pack fully, a new battery pack is needed. NOTE: The charger rapidly charges a battery pack to a specified level, not a completed level, to prevent overcharging. Leave the battery pack in the charger for a few more hours (up to 15 hours; depending on battery condition) after the LED indicator turns green, to charge the battery completely. 10 3 BATTERY PACKS ` Battery case (Option) When using a BP-208 OPTIONAL BATTERY CASE attached to the transceiver, install 6 AA (R6) size alkaline batteries as illustrated below. NOTE: Output power is automatically reduced to 1 W to retain sufficient power in case of an emergency, etc. D CAUTIONS · Use ALKALINE batteries only. · Make sure all battery cells are the same brand, type and capacity. Either of the above may cause a fire hazard or damage the transceiver, if ignored. · Never incinerate used battery cells since internal battery gas may cause them to rupture. If the battery case gets wet, be sure to wipe it dry before using it. 11 PROGRAMMABLE FUNCTIONS ` General 4 In the following explanations, programmable function names are bracketed, the specific switch used to activate the function depends on programming. D KEY LOCK FUNCTION1/2 This function locks access to all programmable switches (except the switch assigned for the lock function): Lock1: All Key Lock function; lockes all keys except Lock, PTT, CALL, Moni, Emergency keys and Channel selector SW. Lock2: Channel selector SW Lock function; lockes all keys except Lock, PTT, CALL, Moni and Emergency keys. Automatic pre-programmed transmission: Push the [DTMF Autodial] switch to send a DTMF code. D EMERGENCY FUNCTION The emergency function allows you to send your ID quickly and easily to your Base Station, etc. · The transceiver selects a pre-programmed channel, then sends an emergency signal to your Base Station. · The pre-programmed channel remains selected until a control signal is received from the Base Station, or power is turned OFF. · The emergency call is repeatedly transmitted at pre-programmed intervals. D MR-CH1, MR-CH2, MR-CH3, MR-CH4 This function temporarily allows you to select one of memory CH1 to CH4, when you push the [MR-CH1­4] key. 15 PROGRAMMABLE FUNCTIONS 4 D CODE SQUELCH This conveniently eliminates unwanted audio and is useful in group activities or security related activities where unwanted output can be a problem. In order to use the above functions, cloning is necessary via a PC using the optional CS-F11 cloning software. Using this software, the transceiver's model, individual RX Code CH, TX Code CH, Special Tone Link2 (must be `E') in 5Tone screen, 5Tone Signaling Form in Memory-CH screen, Log, RX C-No, Key&Display, Common AutoReset TimerB, and other settings related to operation can be set. Refer to the HELP file that comes with the CS-F11 CLONING SOFTWARE for available settings. 16 5 CONVENTIONAL OPERATION ` Receiving and transmitting NOTE: Transmitting without an antenna may damage the transceiver. [. . . ] · SP-13 EARPHONE Provides clear receive audio in noisy environments. · AD-98FSC ANTENNA CONNECTOR ADAPTER Allows you to connect a BNC-type antenna. · OPC-474 CLONING CABLE Cloning cable for transceiver to transceiver 22 8 CE CE Versions of the IC-F12/S, F22/S which display the "CE" symbol on the serial number seal, comply with the essential requirements of the European Radio and Telecommunication Terminal Directive 1999/5/EC. ABOUT CE This warning symbol indicates that this equipment operates in non-harmonised frequency bands and/or may be subject to licensing conditions in the country of use. Be sure to check that you have the correct version of this radio or the correct programming of this radio, to comply with national licensing requirement. INSTALLATION NOTES · When transmitting with a portable radio, hold the radio in a vertical position with its microphone 2. 5 to 5 centimeters away from your mouth. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-F12




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-F12 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.