User manual ICOM IC-R6

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ICOM IC-R6. We hope that this ICOM IC-R6 user guide will be useful to you.


ICOM IC-R6 : Download the complete user guide (9670 Ko)

You may also download the following manuals related to this product:

   ICOM IC-R6 BROCHURE (3620 ko)

Manual abstract: user guide ICOM IC-R6

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL COMMUNICATIONS RECEIVER iR6 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE C E L L U L A R R A D I OT E L E P H O N E S E RV I C E S I G N A L S I S PROHIBITED UNDER FCC RULES AND FEDERAL LAW. FOREWORD Thank you for purchasing this Icom product. The IC-R6 communications receiver is designed and built with Icom's superior technology and craftsmanship. [. . . ] 30 6 SCAN OPERATION Programming scan name Each pair of scan edge channels can be programmed with an alphanumeric scan name for easy recognition, and can be displayed during scan selection. e Hold down [S. MW](V/M) for 1 second to enter the select memory write mode. · 1 short and 1 long beep sounds. · The " " icon and memory channel number blink. t While holding down [FUNC], rotate [DIAL] to select a desired character. · The selected character blinks. y Rotate [DIAL] to move the cursor to the left or to the right. u Repeat steps t and y until a desired 6-character scan name is displayed. i Hold down [S. MW](V/M) for 1 second to program the name and exit the programming mode. · 3 beeps sound. r While holding down [MODE], rotate [DIAL] to select the "S NAME" item. · The item can also be selected by repeatedly pushing [MODE]. · After releasing [MODE], a line blinks under the first digit, and the " " icon blinks. · Available characters A to Z, 0 to 9, ( , ) , *, +, ­, , , /, |, = and space. Therefore, the programmed scan name is automatically assigned to another edge channel. 31 SCAN OPERATION 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Programming other contents The programmed scan can store the scanning step, receive mode and attenuator settings. e Hold down [S. MW](V/M) for 1 second to enter the select memory write mode. · 1 short and 1 long beep sounds. · The " " icon and memory channel number blink. t Rotate [DIAL] to select a desired option. Or, select the "-- -- -- --" display when erasing the contents -" from the option. · If "-- -- -- --" is selected in this step, the program scan uses the -" VFO settings. yHold down [S. MW](V/M) for 1 second to program the name and exit the programming mode. · 3 beeps sound. During the full/band scan: The selected tuning step, received mode and attenuator settings in each frequency band are used. During the programmed/programmed link scan: The programmed tuning step, received mode and attenuator settings in each programmed scan edge are used. r While holding down [MODE], rotate [DIAL] to select the "TS, " "MODE" or "ATT" item when programming the tuning step, the receive mode or the attenuator setting. · The item can also be selected by repeatedly pushing [MODE]. Attenuator setting After released. 32 6 SCAN OPERATION Memory/all bank/bank link/bank scan q Push [V/M] to select the memory mode. e Hold down [SCAN](MODE) for 1 second to enter the scan type selection mode. r Rotate [DIAL] to select a desired scanning type. · Select "M-ALL" for all memory scan, "B-ALL" for all bank scan, "B-LINK" for bank link scan or "BANK-x" for bank scan (x= A to R, T, U, W, Y; only programmed bank groups are displayed). t To start the scan, push [SCAN](MODE). · The scan pauses when a signal is received. During memory/ all bank/bank link scan During bank scan [DIAL] Hold down for 1 sec. Rotate · All memory scan · Bank link scan IMPORTANT: To perform a memory or bank scan, two or more memory/bank channels MUST be programmed, otherwise the scan will not start. · All bank scan · Bank scan Selectable between "A" to "R, " "T, " "U, " "W" or "Y, " if programmed (p. 20) See page 53 for details of the bank link programming. 33 SCAN OPERATION 6 Auto memory write scan This scan is useful for searching a specified frequency range, and automatically storing busy frequencies into memory channels. The same frequency ranges used for a program scan are also used for an auto memory write scan. Hold down [SCAN](MODE) for 1 second to enter the scan type selection mode. Rotate [DIAL] to select a desired scanning type. · Select "ALL" for full scan, "BAND" for band scan, "P-LINK x" for programmed link scan (x= 0 to 9), "PROGxx" for programmed scan (xx= 0 to 24; only programmed scan edge numbers are displayed). D During auto memory write scanning: · When a signal is received, the scan pauses for approximately 5 seconds and the frequency is stored into an auto memory write channel group (AW000­AW199). - 2 short beeps sound when stored. · The scan resumes after frequency storing. · When all channels are stored, the scan automatically stops and 1 long beep sounds. 6 D Re-calling the stored frequencies: q Push [V/M] to select the memory mode. w Push [BAND] repeatedly, or while holding down [BAND], rotate [DIAL], to select the auto memory write channel group. · "AW" appears. Push [SCAN](MODE) to start the scan. w Push [V/M] to turn the auto memory write function ON or OFF. · The " " icon blinks. [. . . ] · CT-17 ci-v level converter For receiver remote control using a PC. Approved Icom optional equipment is designed for optimal performance when used with an Icom receiver. Icom is not responsible for the destruction or damage to an Icom receiver in the event the Icom receiver is used with equipment that is not manufactured or approved by Icom. 79 q Cut w Fold e Complete POCKET GUIDE 16 Important operating instructions are summed up on this and the following page for your simple reference. By cutting along the line and folding on the dotted line, it will become a card sized operating guide which can easily be carried in a card case or wallet, etc. iR6 VFO and memory mode selection Push [V/M] to toggle between the VFO and the memory mode. Receive mode selection Push [MODE] repeatedly to select a desired mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-R6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-R6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.