Detailed instructions for use are in the User's Guide.
[. . . ] E SeriesTM Broadband Services Routers
E120 and E320 Hardware Guide
Release
11. 3. x
Published: 2010-09-29 Copyright © 2010, Juniper Networks, Inc.
Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www. juniper. net Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. [. . . ] One port provides direct CLI access from a console terminal; the other Auxiliary port provides debug access from a console terminal.
·
The management port is considered a data terminal equipment interface (DTE). Direct connection to a terminal or PC (which also have DTE interfaces) requires a crossover cable. See "Accessing E Series Routers" on page 59 for more information about management access.
Connecting to the Network
To connect the router to the network:
1.
Insert an Ethernet cable (RJ-45) connector into the 10/100Base-T (RJ-45) port on the SRP IOA until it clicks into place.
2. Connect the other end of the cable to the appropriate Ethernet network for an
out-of-band connection.
Connecting to a Console Terminal
When you connect a console directly to the SRP IOA, use a cable appropriate for your terminal connector. The cable must have a female DB-9 connector to attach to the RS-232 port on the SRP IOA. To connect the console to the SRP IOA:
1.
Insert the female DB-9 connector into the RS-232 port, and tighten the screws.
CAUTION: Do not overtighten the screws.
2. Connect the other end of the cable to your terminal's serial port (VT100/ANSI).
Cabling IOAs
This section describes the common connector types used with IOAs.
LC Duplex Connectors
In accordance with EN60825-1, Safety of Laser Products - Part 1: Equipment Class, Requirements, and User's Guide (2001), multimode IOAs with LC connectors are defined as follows:
Copyright © 2010, Juniper Networks, Inc.
49
E120 and E320 11. 3. x Hardware Guide
CLASS 1 LED PRODUCT. In accordance with EN60825-1, Safety of Laser Products - Part 1: Equipment Class, Requirements, and User's Guide (2001), single-mode IOAs with LC connectors are defined as follows: CLASS 1 LASER PRODUCT.
WARNING: Do not look directly into LC-style fiber connectors. The fiber-optic laser used in single-mode fiber (SMF) meets the regulatory requirements for casual exposure to the eye; however, looking directly into a laser can cause eye damage.
WARNING: EN60825-1, Class 1 laser fiber connectors are for connection only to Class 1 laser devices.
SFPs
See "IOAs Requiring SFPs" on page 32 and the E120 and E320 Module Guide for information on small form-factor pluggable transceivers (SFPs) used on IOAs.
Cabling the Router for Power
After you have correctly cabled the SRP IOA, you must attach grounding and electrical wires before you attempt system power-up. Three main tasks are involved:
1.
Switch all router power switches to OFF.
CAUTION: Switches may have inadvertently flipped to ON during shipping and installation.
2. Connect the grounding wires to the chassis.
WARNING: Always connect the grounding wires first (before connecting the power cables) and disconnect them last when installing or servicing the router.
3. Connect the power cables to the PDUs.
See "System Specifications" on page 89 for the power requirements for the router. Table 8 on page 51 identifies the cabling requirements.
50
Copyright © 2010, Juniper Networks, Inc.
Chapter 5: Cabling the Router
Table 8: E320 Router PDU Cables and Wires Needed
Cable/Wire
One 6-AWG ground wire Two 4-AWG wire leads Two 4-AWG wire leads
From
PDU ground terminal PDU Power A 48 VDC and RTN leads PDU Power B 48 VDC and RTN leads
To
Termination ground Appropriate leads on power source No. 1 Appropriate leads on power source No. 2
Figure 27 on page 51 shows the main components of a PDU.
Figure 27: PDU
Task 1: Turn Off All Router Power
Before starting to cable the router, push all router power switches to OFF to turn off the router.
Copyright © 2010, Juniper Networks, Inc.
51
E120 and E320 11. 3. x Hardware Guide
Task 2: Connect the Grounding Cables
The router has two grounding studs located in the rear of the chassis, near the power inputs. To ground each power unit:
1.
Locate the grounding studs on the router (Figure 27 on page 51).
2. Remove the nuts and locking washers from the grounding studs.
NOTE: We recommend a minimum of 6-AWG ground wire with a ring-style terminal.
3. Place the grounding cable lead on one of the grounding studs and tighten the nuts to
secure the connection.
4. Connect the other end of the ground cable to the appropriate ground termination
lead.
5. Repeat Steps 34 for the remaining grounding stud.
NOTE: When grounding the router, leave a service loop in the grounding cable to ensure that the grounding cable is the last cable to disconnect from the shelf if strain is placed on the electrical cables.
Task 3: Connect the Power Cables
To connect power cables to the router, follow these steps. See Figure 27 on page 51 as needed.
NOTE: Juniper Networks has qualified an AC power supply unit for use with the router. Contact your account representative for more information.
WARNING: Before you begin this procedure, be sure the power source is turned off, the router is turned off, and proper grounding wires are attached.
1.
Be sure you have completed "Task 1: Turn Off All Router Power" on page 51 and "Task 2: Connect the Grounding Cables" on page 52.
2. If applicable, loosen the screws from the clear power input module cover and remove
it.
WARNING: The wiring color code of the power cables depends on the color coding of the DC power source installed at your site. Color code
52
Copyright © 2010, Juniper Networks, Inc.
Chapter 5: Cabling the Router
standards for DC wiring do not exist. [. . . ] See Table 19 on page 108 for the pinouts of the Ethernet cable's RJ-45 connector.
Table 19: SRP IOA RJ-45 Connector Pinout
Pin
1
Signal
TX +
108
Copyright © 2010, Juniper Networks, Inc.
Appendix C: Cable Pinouts
Table 19: SRP IOA RJ-45 Connector Pinout (continued)
Pin
2 3 4 5 6 7 8
Signal
TX RX + no connect no connect RX no connect no connect
To facilitate connecting the system to a terminal, the system is shipped with one of each of the following cable adapters:
· ·
DB-9 female to RJ-45 female crossover null modem adapter DB-9 female to RJ-45 female straight-through adapter
Table 20 on page 109 lists the pinouts for the crossover adapter.
Table 20: DB-9 RJ-45 Crossover Adapter Pinout
DB-9 Pin
1 2 3 4 5 6 7 8 9
Signal
DCD RXD TXD DTR GND DSR RTS CTS RNG
RJ-45 Pin
1 3 2 6 5 4 8 7 no connect
Table 21 on page 110 lists the pinout for the straight-through adapter.
Copyright © 2010, Juniper Networks, Inc.
109
E120 and E320 11. 3. x Hardware Guide
Table 21: DB-9 RJ-45 Straight-Through Adapter Pinout
DB-9 Pin
1 2 3 4 5 6 7 8 9
RS-232 Signal Name
DCD RXD TXD DTR GND (signal) DSR RTS CTS RNG
RJ-45 Pin
1 2 3 4 5 6 7 8 no connect
Ethernet Signal Name
TX + TX RX + no connect no connect RX no connect no connect none
110
Copyright © 2010, Juniper Networks, Inc.
APPENDIX D
Contacting Customer Support and Returning Hardware
See the Juniper Networks Web site for complete customer service information:
·
http://www. juniper. net/support/guidelines. html
This appendix contains the following sections:
· · · · · ·
Contacting Customer Support on page 111 Return Procedure on page 111 Locating Component Serial Numbers on page 112 Information You Might Need to Supply to JTAC on page 113 Tools and Parts Required on page 114 Returning Products for Repair or Replacement on page 114
Contacting Customer Support
For your convenience, we provide multiple options for requesting and receiving technical support from the Juniper Networks Technical Assistance Center (JTAC):
·
By the Web using Juniper Networks, Inc. Case Manager:
https://www. juniper. net/cm/index. jsp
·
By telephone: From the US, Canada, and Mexico at 1888314JTAC From all other locations at 4087459500
Return Procedure
When you need to return a component, follow this procedure:
1.
Determine the part number and serial number of the component. For instructions, see "Locating Component Serial Numbers" on page 112.
Copyright © 2010, Juniper Networks, Inc.
111
E120 and E320 11. 3. x Hardware Guide
2. Obtain a Return Materials Authorization (RMA) number from the Juniper Networks
Technical Assistance Center (JTAC). [. . . ]