User manual KONICA MINOLTA CM-2600D BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KONICA MINOLTA CM-2600D. We hope that this KONICA MINOLTA CM-2600D user guide will be useful to you.


KONICA MINOLTA CM-2600D BROCHURE: Download the complete user guide (1789 Ko)

You may also download the following manuals related to this product:

   KONICA MINOLTA CM-2600D BROCHURE (821 ko)
   KONICA MINOLTA CM-2600D BROCHURE 2 (2216 ko)

Manual abstract: user guide KONICA MINOLTA CM-2600DBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] SPECTROPHOTOMETER CM-2600d Portable, Compact, Easy to Use Performs Like a Desktop Spectrophotometer World's first portable spectrophotometer equipped with automatic UV adjustment function. Advanced Numerical UV Control dramatically reduces evaluation time. The CM-2600d is a portable integrating sphere spectrophotometer designed for versatility in various applications. Simultaneous measurement of SCI (specular component included) and SCE (specular component excluded). Advanced Numerical Gloss Control. Simultaneous measurement of SCI and SCE displays data on the LCD in 1. 5 seconds. [. . . ] UV evaluation time has been reduced revolutionarily due to the introduction of advanced Numerical UV Control. Light sources including and excluding UV component flash sequentially to provide sample data taken with UV-included energy as well as UV-excluded energy (UV400nm cutoff filter) Since the instrument has a built-in instantaneous Example of data taken with UV-excluded energy Example of data taken after UV adjustment Measures at 10nm intervals for the full wavelength range. Excellent repeatability High-accuracy sensor Illuminated viewfinder UV adjustment function, data can be easily taken using the desired light source (e. g. UV calibration can be performed simply by measuring a standard with known fluorescent values under the desired light source. Once the UV calibration is completed, sample data can be taken by measuring UV included the sample under the desired light source. Since the conventional UV adjustment that requires the UV cutoff filter to be moved is not necessary, UV excluded measurement time can be reduced drastically. (Note on UV-Adjustment : Numerical UVFor textile, paper, fluorescent and consumerproducts calibration requires for the adjustment calculation SpectraMagic NX. ) TM Numerical Gloss Control Numerical UV Control Easy-to-carry, compact and lightweight 670g (without batteries) d/8 integrating sphere optics that conform to industry standards SpectraMagic NX enables you to perform comprehensive color inspection and analysis of incoming raw materials, in process production, and outbound color critical goods and materials in virtually any industry. With SpectraMagic NX you can insert digital images with measured data. Select from 15 illuminants, and up to 40 indices to determine specific color and appearance properties, such as strength, brightness, haze, yellowness, opacity and strength. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagic NX comes with predefined templates using skin technology, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's well known and respected "Precise Color Communication". SpectraMagic NX conforms to FDA 21 CFR Part 11 assuring integrity and reliability of data records. TM TM TM TM Allows measurement in any position. Compact, lightweight with an easy-to-operate navigation wheel and large LCD display. The battery-powered small, compact body allows the instrument to be placed in any position at the sample surface. The large LCD reverse video display provides easy reading, irrespective of which hand it is held in. Using your finger, the navigation wheel allows simple and user-friendly operation. ( Turn) ( Push) For paints, plastics, automobiles, ceramics, architectural interiors, textile, paper, food etc. Measures the target with high accuracy. [. . . ] * Total of the sample data for the COND and TASK modes and color difference target data Tolerance judgment Tolerance for color difference (both box and eliptical tolerances can be set) Power source 4 AA-size battery or AC adapter Size (WxHxD) 69 x 96 x 193mm Weight Approx. 670g (without batteries) Operating temperature/ 5 to 40°C, relative humidity 80% or less (at 35°C) with no humidity range (*1) condensation Storage temperature/ 0 to 45°C, relative humidity 80% or less (at 35°C) with no humidity range condensation Standard White calibration plate, Target mask ø8mm, Target mask ø3mm , accessories RS-232C cable, AC adapter, AA-size battery (x4) Optional Hard case, Dust cover set, Dust cover, Accessories SpectraMagic NX (software), Zero calibration box TM System Diagram Standard Accessories Optional Accessories Target mask ø3mm CM-A147 Target mask ø8mm CM-A146 AA-size AC Adapter AC-A17 battery (x4) AC Adapter AC-A23 (for Korea) Personal Computer (commercially available) RS232C cable IF-A16 CM-2600d White calibration plate CM-A145 SpectraMagic NX CM-S100w TM Zero calibration box CM-A32 Hard case CM-A148 Dust cover set Vinyl cover Dust cover CM-A149 CM-A152 Dimensions (Units:mm) CM-2600d 69 193 *1 Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation CM-3700d CM-3600d Color control network by spectrophotometer High inter-instrument agreement between the portable CM-2600d spectrophotometer and the desk top CM-3000 series make it easy to build a total color control network. CM-2600d R&D Quality Production R&D R&D CM-2600d Company A Quality control Production Quality Production Company B In-house color control Color control among companies * The specifications and drawings given here are subject to change without prior notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Using improper batteries may cause a fire or electric shock. Certificate No : YKA 0937154 Registration Date : March 3, 1995 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 ©2001 KONICA MINOLTA SENSING, INC. 9242-4879-11 AGMGPK 9 Printed in Japan 96 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA CM-2600D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA MINOLTA CM-2600D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.