User manual LA CROSSE TECHNOLOGY WS-2310

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-2310. We hope that this LA CROSSE TECHNOLOGY WS-2310 user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-2310 : Download the complete user guide (448 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY WS-2310 QUICK START (203 ko)
   LA CROSSE TECHNOLOGY WS-2310 SOFTWARE MANUAL (1542 ko)
   LA CROSSE TECHNOLOGY WS-2310 OPERATION MANUAL (907 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-2310

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual Professional Remote Weather Station Table of Contents Page Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features of the rain sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] It represents not the real measured but the temperature a person feels in open area under the influence of wind and cold. Windchill is laid out in tables for various temperatures and wind speeds. 46. 4°F and calm winds a person moving at a speed of 13 mph will already feel a windchill temperature of 32°F. Wind Data (LCD Section 3) The current wind direction will be displayed on the LCD compass on the wind section. Press the WIND key to toggle between wind direction as numerical (e. g. SW) as well as numerical wind speed display inside the compass circle. 12. Operation keys ALARM - key The base station has 8 keys for easy operation. Please refer to the following table for use and function of each key: Further descriptions of the key functions with regard to their immediate range of application can be found in the Programming modes: SET - key - In normal mode to enter the manual basic programming mode - In basic programming mode to select the following setting modes: - LCD contrast setting - Manual time setting (hours/minutes) - 12/24 time format display - Calendar setting (year/month/date) - Time zone setting - °C/°F temperature setting - Wind speed unit setting - Rainfall unit setting - Pressure unit setting - Relative air pressure setting - Weather picture threshold setting - Storm warning setting - Audible storm alarm setting - In setting modes confirmation of the selected values - In alarm modes alarm ON/OFF - In alarm mode to enter programming of alarm values (long pressing) - To exit MIN/MAX modes - Toggle between Absolute and Relative air pressure displays - Toggle between the following current/ maximum/ minimum display modes: - Indoor temperature and humidity - Outdoor temperature and humidity - Outdoor wind chill - Outdoor dew point - Rainfall (24h, 1h, total) To toggle between the following settings: - Wind speed - Wind direction - Wind direction display in degrees MIN/MAX - key PLUS (+) ­ key PRESSURE - key DISPLAY - key MINUS (-) ­ key WIND - key - In normal mode to enter the alarm programming mode - In alarm programming mode to select the following setting modes: - Time alarm setting - Indoor temperature alarm (high & low) - Outdoor temperature alarm (high & low) - Indoor humidity alarm (high & low) - Outdoor humidity alarm (high & low) - Outdoor wind chill alarm (high & low) - Outdoor dew point alarm (high & low) - Rainfall alarm (24h, 1h) - Pressure alarm (high & low) - Wind speed alarm (high & low) - Wind direction alarm - In setting modes confirmation of the selected values - To exit MIN/MAX modes - To reset general alarm symbol - In normal display mode to toggle between display of MIN/MAX values - To toggle between MIN/MAX values in MIN/MAX mode - To exit any programming mode - In normal display mode to toggle between format of date display, seconds, time alarm and time zone - To increase the values in the setting modes - To exit MIN/MAX modes - In normal display mode to re-enter data learning mode (long pressing for 2 seconds) - In normal display mode to enable/disable the buzzer alarm (long pressing) - To decrease the values in the setting modes - In basic programming mode audible storm alarm ON/OFF - To snooze the alarms off 24 hours when the alarm is sounding - In MIN/MAX modes to reset recorded values and recorded dates and times 13. Basic Programming Modes Manual Setting modes The manual setting mode allows the user to change several basic settings, which is done by accessing one mode after the other simply by pressing the SET key. After the final mode, or if no key is pressed for 30 seconds, the manual setting returns to the normal display mode. Time zone setting from 0 to +12 hrs, -1, -2, -3, AT -4, ET -5, CT -6, MT -7, PT -8, AL -9, HA -10, -11, -12 (default ET -5) 6. Temperature display unit degree Celsius or Fahrenheit (default degree Fahrenheit) 7. Wind speed display units in m/s, km/h, mph, Beaufort, knots (default setting mph) 8. Relative air pressure setting from 27. 10 inHg ­ 31. 90 inHg (default 29. 98 inHg) 11. Weather forecast sensitivity setting 6, 9, 12 inHg (default setting 9 inHg) 12. Storm warning sensitivity setting 9, 12, 15, 18, 21, 24, 29 inHg (default 9 inHg) 13. Audible storm alarm On/OFF (default ON) To change any of the above values, once your are in the setting mode, use the PLUS (+) or MINUS (-) keys to select the values followed by the SET key to enter the next setting. Continue to press the SET key to toggle through the setting mode until the LCD returns to the normal display mode or press the MIN/MAX key at any time to exit. Keeping the PLUS (+) or MINUS (-) key depressed when setting certain units in the manual setting mode will increase/decrease digits in greater steps. Manual time setting The base station will continue to scan for the radio controlled time signal from 12am-6 am (1am-6pm summer time) each day despite it being manually set. · · If reception has been unsuccessful, then the WWVB tower icon will not appear but reception will still be attempted the following hour within the time frame If reception has been successful, the received time and date will overwrite the manually set time and date and no further reception is attempted until the following day MIN/MAX Programming Modes 14. MIN/MAX display Mode The MIN/MAX Mode provides the user with information about the MIN/MAX values of all weather data together with the time and date at which these values were recorded. the indoor temperature and humidity, press MIN/MAX key to toggle the display between the maximum, minimum and current records. While the maximum or minimum values are shown press the DISPLAY key once to show the time and date that value was received. Now press the MIN/MAX key to toggle from the minimum and maximum readings and the time and dates the records were received are also shown. Still in the MIN/MAX mode (where the time and date for a value are shown), press the DISPLAY key to move through each respective unit as follows: · · · · · · · · Indoor temperature (max or min with time and date) Indoor humidity (max or min with time and date) Outdoor temperature (max or min with time and date) Outdoor humidity (max or min with time and date) Outdoor wind chill (max or min with time and date) Outdoor dew point (max or min with time and date) Rainfall 24 hours (max or min with time and date) Rainfall 1 hour (max or min with time and date) · Rainfall total (max only with time and date) When in any of the above modes, press the MIN/MAX key to toggle between the maximum or minimum values of those records and their respective time and dates will also be shown. [. . . ] This may bear the danger of water entering the unit's inner parts and cause damages. Should there be damage to this product, please do not attempt to make any repairs. Opening or improper handling of the units will invalidate any guarantee. Outdoor data Transmission Distance in Open Field: Temperature Range : Resolution Measuring Range Rel. Humidity : : - Rain Volume Display : Resolution Wind Speed Resolution Wind Direction : : : : 21. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-2310




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-2310 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.