User manual LG AP1300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG AP1300. We hope that this LG AP1300 user guide will be useful to you.


LG AP1300 : Download the complete user guide (181 Ko)

Manual abstract: user guide LG AP1300

Detailed instructions for use are in the User's Guide.

[. . . ] There is risk of fire or electric shock. Always ground the product. · There is risk of fire or electric shock. Install the panel and the cover of control box securely. · There is risk of fire or electric shock. Always install a dedicated circuit and breaker. · Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse. · There is risk of fire or electric shock. Do not modify or extend the power cable. · There is risk of fire or electric shock. Do not install, remove, or reinstall the unit by yourself (customer). · There is risk of fire, electric shock, explosion, or injury. Be cautious when unpacking and installing the product. · Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator. Owner's Manual 3 Safety Precautions For installation, always contact the dealer or an Authorized Service Center. · There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. · It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. · If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. n Operation Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. · Moisture may condense and wet or damage furniture. Take care to ensure that power cable could not be pulled out or damaged during operation. · There is risk of fire or electric shock. Do not place anything on the power cable. · There is risk of fire or electric shock. Do not plug or unplug the power supply plug during operation. · There is risk of fire or electric shock. Do not touch(operate) the product with wet hands. · There is risk of fire or electrical shock. Do not place a heater or other appliances near the power cable. · There is risk of fire and electric shock. Do not allow water to run into electric parts. · It may cause There is risk of fire, failure of the product, or electric shock. Do not store or use flammable gas or combustibles near the product. · There is risk of fire or failure of product. Do not use the product in a tightly closed space for a long time. · Oxygen deficiency could occur. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. · Do not use the telephone or turn switches on or off. There is risk of explosion or fire If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. · There is risk of electric shock or fire. Stop operation and close the window in storm or hurricane. [. . . ] Do not expose occupants, pets, or plants to direct airflow for a long time. Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with stoves or other heating devices. Do not use this air conditioner for non-specified special purpose (e. g. Exposure to water can destroy the insulation, leading to electric shock. When cleaning the unit, first make sure that the power and breaker are turned off. There is a possibility of injury if the units power is triggered while cleaning inner parts of the unit. Service For repair and maintenance, contact your authorized service dealer. Introduction Symbols used in this Manual This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to the air conditioner. NOTICE This symbol indicates special notes. 6 Floor Standing-Type Air Conditioner Operating Instructions Safety Precautions ENGLISH Operating Instructions Features and Specifications 1. 3D Stereo Cooling This first developed 3D Stereo Cooling Method makes clear a dead zone to cool the indoor evenly within a early time. Edge Installation Design You can use the installation space in a effective way to adopt semi built-in type of 3D Diamond design. Magic Remote You can keep remote controller conveniently with separate holder on the side of the product. Base Panel (It is made of special materials of durability, rust-resistance and non-coating. ) 5. Press the Airflow Direction Control Button again to set the Vertical louver at the desired airflow direction. A/CL (Operation will start when the button is pressed, and stop when the button is pressed again. The vertical louver swing left and right. 18 Floor Standing-Type Air Conditioner Operating Instructions ENGLISH Plasma Air Purifying Operation Procedure 1 Air Purifying Operation only Press(Touch) the Plasma Air Purifying Operation On/Off Button(Key). 1 A/CL SET ROOM TURBO-Z TEMP. ON/OFF PLASMA (Operation will start when the button is pressed, and stop when the button is pressed again. ) 2 The display shows low fan speed at the initial condition. Select Fan speed. TURBO-Z High ROOM TURBO-Z TEMP. ON/OFF PLASMA Low ROOM TURBO-Z TEMP. ON/OFF PLASMA · You can operate the Plasma Air Purifying under the unit operation of cooling, heating, soft dry or Auto mode. 2 Air Purifying Operation with Cooling or any other Operation. 1. Set the fan speed. Owner's Manual 19 Operating Instructions OFF Timer Setting Procedure(OFF TIMER Setting, or CANCEL) 1 Press the on/off button. (or touch the anyplace of touch panel and touch the on/off key) TURBO-Z SET ROOM TURBO-Z TEMP. ON/OFF PLASMA 2 Press the Timer Button. A/CL SET ROOM TURBO-Z TEMP. ON/OFF PLASMA · If you press the button, the selected off timer is displayed as follows; · If you select , the Off Timer function will be cancelled. 3 When you finish the Off Timer setting, the Timer indicator lights off. After 4 seconds After 4 seconds SET ROOM TURBO-Z TEMP. ON/OFF PLASMA SET TEMP. TURBO-Z ON/OFF PLASMA ROOM TURBO-Z TEMP. ON/OFF PLASMA 4 During off-timer operation if you press the Timer Button, the rest time will be displayed. 20 Floor Standing-Type Air Conditioner Operating Instructions ENGLISH Child Lock Operation Procedure 1 Touched the fan speed and high temperature setting keys simultaneously for 3 seconds. The unit will respond with beep. ROOM TEMP. TURBO-Z ON/OFF PLASMA ROOM TURBO-Z TEMP. ON/OFF PLASMA ROOM TURBO-Z TEMP. ON/OFF PLASMA After 3 second, it will shift ROOM TURBO-Z TEMP. ON/OFF PLASMA After 3 second, it will shift 2 During Child Lock Operation Whenever you Touch any key on Touch panel, it will immediately display " ", which means Touch panel is Locked. But the key on the remote controller will work. 3 Touched the fan speed and high temperature setting keys simultaneously for 3 seconds again. For releasing child lock Operation The unit will respond with beep, Child Lock Operation will removed. ROOM TURBO-Z TEMP. ON/OFF PLASMA ROOM TURBO-Z TEMP. ON/OFF PLASMA ROOM TURBO-Z TEMP. ON/OFF PLASMA After pressing the buttons it will shift immediately ON/OFF PLASMA TURBO-Z ROOM TEMP. After 3 seconds, it will shift Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. Owner's Manual 21 Maintenance and Service Maintenance and Service Indoor Unit WARNING: Turn the system off before cleaning. Do not use bleach or abrasives. NOTICE Supply power must be disconnected before cleaning the indoor unit. How to Clean Plasma Deodorant Air Cleaner At the smoking area, it is better to clean more than once in a month, otherwise in the other places, once in every 3 months will be good. The antibiotic filter should be clean without disassembly as it is united with air inlet. Remove off green tape on the surface of plasma air cleaner and then pull out the knob of cleaner. The plasma air cleaner is located on the inner side of right air cleaner. Soak the plasma deodorant air cleaner in the mixed detergent water for 1to 2 hours and clean it throughout. Dry it in the shade throughout and insert its electrode into the spring correctly. - When the inner side color of air cleaner changes into yellowish, dry it under the sunlight. [. . . ] This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency. Water may be collected in the base pan in highly humid conditions or on rainy days. This is a normal operational feature. 24 Floor Standing-Type Air Conditioner Maintenance and Service ENGLISH Troubleshooting The air conditioner may be operating abnormally when: Problem Possible Causes n The air conditioner is unplugged. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG AP1300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG AP1300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.