User manual LG PQRCVCL0QW

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG PQRCVCL0QW. We hope that this LG PQRCVCL0QW user guide will be useful to you.


LG PQRCVCL0QW : Download the complete user guide (2291 Ko)

You may also download the following manuals related to this product:

   LG PQRCVCL0QW (2356 ko)

Manual abstract: user guide LG PQRCVCL0QW

Detailed instructions for use are in the User's Guide.

[. . . ] ① Reclamation to the surface of the wall ② Upper part guide groove ③ Right part guide groove <Wire guide grooves> Ownerʼs & Installation Manual 5 Installation instruction 3. Please connect indoor unit and remote controller using connection cable. Please check if connector is normally connected. FAN SPEED TEMP OPER MODE Indoor Unit side Connecting cable 4. Please use extension cable if the distance between wired remote controller and indoor unit is more than 10m. Please fix remote controller upper part into the setup board attached to the surface of the wall, as the picture below, and then, connect with setup board by pressing lower part. - Please connect not to make a gap at the remote controller and setup boardʼs upper and lower, right and left part. <Connecting order> Wall Side Wall Side When separating remote controller from setup board, as the picture below, after inserting into the lower separating hole using screw driver and then, spinning clockwise, remote controller is separated. - There are two separating holes. [. . . ] - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. • Precaution shall be taken not to alter the E. S. P value corresponded to each air flow section. • In the case of going to the next air flow rate stage by pressing the fan-speed button during the setup of the E. S. P value, the E. S. P value of previous air flow rate will be maintained by remembering the E. S. P value prior to the shift. Ownerʼs & Installation Manual 11 Installation instruction Installer Setting -Thermistor This is the function to select the temperature sensor to judge the room temperature. button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the thermistor sensor setting code value by pressing the button. * Thermistor sensor selection code value : 04 OPER MODE FAN SPEED TEMP OPER MODE 2 Select the desired setting value with the temperature up(▲), down(▼) button. Code value Value *Setting value 01: Remote controller 02: Indoor unit 03: 2TH button, currently 3 When pressing the sensor location established thermistor will be set up. 4 When pressing the button and button simultaneously for more than 3 seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. OPER MODE • As the characteristic of the ʻ2THʼ function can be different in accordance with the products, refer to the product instruction manual for its detail. 12 Wired Remote Controller Installation instruction ENGLISH Installer Setting -Ceiling Height Selection This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product) button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the button. * Ceiling height setting code value : 05 OPER MODE 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE Code value Value *Setting value 01: Low 02: Standard 03: High 04: Very high currently 3 When pressing the heightbutton, will be established ceiling value set up. button 4 When pressing the for moreand 3 button simultaneously than OPER MODE • As the ceiling height setting standard can be different in accordance with the products, refer to the product instruction manual for its detail. seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. <Ceiling Height Selection Table> 01 02 03 04 Ceiling Height Level Low Standard High Very high Description Decrease the indoor airflow rate 1 step from standard level Set the indoor airflow rate as standard level Increase indoor airflow rate 1 step from standard level Increase indoor airflow rate 2 steps from standard level • Ceiling height setting is available only for some products. • Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit. Ownerʼs & Installation Manual 13 Installation instruction Installer Setting -Static Pressure Setting This function is applied to only duct type. Setting this in other cases will cause malfunction. button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the oper-mode button. * Static pressure setting code value : 06 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE Code value Value *Setting value 01:V-H 02:F-H 03:V-L 04:F-L button, currently 3 When pressing pressure value will be established static set up. button 4 When pressing the for moreand 3 button simultaneously than OPER MODE seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. <Static Pressure Setting Table> Pressure selection 01 02 03 04 V-H F-H V-L F-L Function Zone state Variable Fixed Variable Fixed ESP standard value High High Low Low 14 Wired Remote Controller Installation instruction ENGLISH Installer Setting-Remote Controller Master/Slave Setup It is a function for settings in group control, or 2-remote controller control. button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the oper-mode button. * Remote controller master/slave setting code value : 07 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE *Setting value 00:Slave 01:Master Code value Value button, currently 3 When pressing thepressure value will be established static set up. 4 When pressing the forbutton and 3 button simultaneously more than OPER MODE seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. Remote controller Master Slave Function Indoor unit operates based on master remote controller at group control. (Master is set when delivering from the warehouse. ) Setup all remote controllers except one master remote controller to slave at group control h Refer to the 'group control' part for details • When controlling in groups, basic operation settings, airflow strength weak/medium/strong, lock setting of the remote controller, time settings, and other functions may be restricted. Ownerʼs & Installation Manual 15 Installation instruction Installer Setting-Celsius / Fahrenheit Switching This function is used for switching the display between Celsius and Fahrenheit. (Optimized only for U. S. A) 1 When pressing the button and button simultaneously for more than 3 seconds, the system will be entered into the installer setting mode. [. . . ] operate cooling or 2 If one indoor unitmode while several indoor dehumidification units are operating heating mode, outdoor segment and cooling segment are blinking. button, 3 If pressing runs at theindoor unit different automatically mode that indoor units are running after about 5 seconds and operates. FAN SPEED TEMP OPER MODE • If the product is not compatible with the different mode operation, LCD will be displayed ʻCH07ʼ. • Different mode operation is not error. Ownerʼs & Installation Manual 27 Owner's instruction Checkups before reporting breakdown Please first check the items below for product's defects before consulting to service center. • Please set up desired temperature lower than current temperature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG PQRCVCL0QW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG PQRCVCL0QW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.