User manual LG R5209

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LG R5209. We hope that this LG R5209 user guide will be useful to you.


LG R5209 : Download the complete user guide (949 Ko)

Manual abstract: user guide LG R5209

Detailed instructions for use are in the User's Guide.

[. . . ] · If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Do not modify power cord length or share the outlet with other appliances. · It will cause electric shock or fire due to heat generation. Do not operate with wet hands or in damp environment. · It will cause electric shock. Do not direct air flow at room occupants only. · This could lead to health problems. 3 Safety Precautions When the air filter is to be removed, do not touch the metal parts of the unit. · They are sharp and may cause an injury. Do not clean the air conditioner with water. When the unit is to be cleaned, switch the unit off, and unplug it. · Since the fan rotates at high speed during operation, it may cause an injury. · Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not operate the unit without the air filter or when the front intake grille has been removed. · It could cause dust to accumulate on the heat exchanger. Do not put a pet or house plant where it will be exposed to direct air flow. · This could injure the pets or plants. Do not use for special purposes. · Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc. Do not operate switches with wet hands. · It may cause an electric shock. Do not apply an insecticide or flammable spray. · It may cause a fire or deformation of the cabinet. SHARP EDGES! [. . . ] The top of the wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside. Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strips are not necessary. INNER SILL WOOD STRIP MOUNTED ON TOP OF INNER SILL 1" MAX. /4" CLEARANCE STORM WINDOW FRAME 3 Features and Installation INNER SILL OUTER SILL INDOORS Fig. 5-1 WOOD STRIP FOR L BRACKET OUTER SILL OUTDOORS INDOORS Fig. 5-2 OUTDOORS Installation HARDWARE TYPE A: 11EA (SHORT SCREW) 10mm TYPE B: 5EA (WOOD SCREW) 16mm TYPE C: 3EA (L BRACKET) TYPE D: 1EA (SEAL STRIP) TYPE E: 1EA (SASH SEAL) TYPE F: 2EA (GUIDE PANEL) TYPE G: 1EA (SUPPORT BRACKET) (Adhesive backed) (Not adhesive backed) 8 A. Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. LOCATING UNIT IN WINDOW Open the window and mark center line on the center of the inner sill, as shown in Fig. Install the L brackets behind the inner window sill, with short side of bracket as shown. 8 INNER SILL TYPE A OUTER SILL INSIDE CAUTION During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. IMPORTANT : When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening as shown in Fig. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Fig. 9 8" 8" OUTSIDE L BRACKET CENTER LINE Features and Installation Fig. 10 WINDOW FRAME UPPER GUIDE CENTER LINE SEAL ABOUT 1/4" BOTTOM GUIDE Fig. SECURE THE GUIDE PANELS Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. [. . . ] Repairs when your LG product is used in other than normal, single-family household use. Damage resulting from accident, alteration, misuse, abuse, or improper installation. If the product is installed outside the normal service area, any cost of transportation involved in the repair of the product, or the replacement of a defective parts, shall be borne by the owner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG R5209




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LG R5209 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.