User manual LIFT-MASTER 90 T1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER 90 T1. We hope that this LIFT-MASTER 90 T1 user guide will be useful to you.


LIFT-MASTER 90 T1 : Download the complete user guide (322 Ko)

Manual abstract: user guide LIFT-MASTER 90 T1

Detailed instructions for use are in the User's Guide.

[. . . ] Timer will close door (after a preset, adjustable interval) when the door is opened from certain or all devices, but will leave door open when the door is opened by any other means. These devices are designated by the terminal points to which they are connected. Any device wired to activate the timer (as described above) will also reset the timer to the preset interval if it is energized during the timing period. [. . . ] Mount the 4 position TERMINAL BLOCK on the back wall above the 10 position terminal block, use the holes that are 1" from the top lip of the box. Use (2) #10-32 x 5/8" long self tapping screws to secure in place. Refer to electrical box layout below for location of components in the box. RED ORANGE ORANGE COIL PURPLE PURPLE RED NEW R1 RELAY (wires from old R1 relay) TYPICAL ELECTRICAL BOX LAYOUT MOV RADIO TERMINAL BLOCK (if supplied) A1 CONTACTOR 1 2 4 POLE TERMINAL BLOCK 10 POLE TERMINAL BLOCK TIMER 3 4 5 7 10 L1 L2 L3 A2 XFMR AUX. WIRING CONNECTIONS Refer to the illustrations and instructions describe below to wire new components. NOTE: If a residential radio is wired to the operator to open and close door, the receiver must be re-wired to open only (see diagram below). Determine which limit switch is the open auxiliary switch and remove all three wires (yellow, orange and purple) from the switch and the terminals they are attached to, discard wires. From the new R1 relay remove the red wire (that goes from coil of the relay to the R3 terminal on 3 position radio block) from the coil of the relay and install on common of the auxiliary open limit switch. From the new R1 relay install a new 24" red wire from the coil to the normally closed on the auxiliary open limit switch. From the new R1 relay remove red wire from coil that goes to terminal #1 and discard wire. From the new R1 relay connect new 12" red wire from coil to terminal #11. Install the 12" grey wire to the normally open on the new R1 relay that corresponds to the orange wire in step (i) and connect to terminal #11. Install the 3" brown jumper wire between terminals #11 and #12 (if timer defeat switch is going to be used put switch in place of brown jumper wire). Install the 13" blue wire from the #3 on the timer to the orange wire nut. Install the 13" yellow wire from #5 on the timer to terminal #12. Locate MOV (Metal Oxide Varsitor #76-29V30500) this looks like two orange wires with black heat shrink tubing and install from A1 to A2 on the open contactor coil (see figure on pg. For "T1" type wiring install the 14" brown jumper between terminals #1 an #11. Refer to control wiring features on back page to determine desired wiring type. If open and a start timer is not desired move the yellow wire from terminal #7 to terminal #1. [. . . ] Audible/visible Warning device may be light, strobe, horn, buzzer, or other simular device. Separate power source is required. STOP button requiring momentary contact RADIO RECEIVER to open only (24VAC, 3-screw mount) EXTERNAL INTERLOCK switch to open only (24VAC, 3-screw mount) Safety Device (2) to REVERSE while closing Audible/Visible Warning Device (3) on 10 sec. before closing the timer REVERSE (if closing) with momentary contact on OPEN control AUTOMATIC TIMER closes when door is open from any device AUTOMATIC TIMER closes when door is open from selected devices T2 CONTROL WIRING WARNING LIGHT 115V POWER ON OFF TIMER DEFEAT SWITCH OPEN WITH TIMED CLOSING 14 13 12 11 1 2 3 4 5 7 10 1O POWER IN L1 L2 L3 oo T1 CONTROL WIRING WARNING LIGHT 115V POWER ON OFF TIMER DEFEAT SWITCH OPEN WITH TIMED CLOSING OPEN WITH TIMED CLOSING 14 13 12 11 1 2 3 4 5 7 10 1O POWER IN L1 L2 L3 ** Remove jumper when switch is used. oo Remove jumper when timer defeat switch is used. OPEN#2 CLOSE ** *STOP ** CLOSE *STOP EXTERNAL INTERLOCK SAFETY EDGE 3O POWER IN EXTERNAL INTERLOCK SAFETY EDGE ** 3O POWER IN NOTES: * If no STOP button is used, provide a jumper (2 instances) between terminals 3 and 4. NOTES: * If no STOP button is used, provide a jumper (2 instances) between terminals 3 and 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 90 T1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 90 T1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.