User manual LIFT-MASTER BG3100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER BG3100. We hope that this LIFT-MASTER BG3100 user guide will be useful to you.


LIFT-MASTER BG3100 : Download the complete user guide (1747 Ko)

Manual abstract: user guide LIFT-MASTER BG3100

Detailed instructions for use are in the User's Guide.

[. . . ] (01Doc 6001343 (01-20299) Rev B INSTALLATION AND OPERATION INSTRUCTIONS FOR THE 3100MODEL BG 3100-X1 BARRIER GATE OPERATOR (-73 BOARD) TABLE OF CONTENTS THE LIFTMASTER MODEL BG 3100-X1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 BASIC INSTALLATION HINTS AND RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PART 1 SITE PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Using the manual controls (Figure 6), initiate gate opening, then stop the gate about one foot short of its fully open position. After about one minute the gate should start opening and stop at its fully open limit. Using the manual controls, initiate gate closing, then stop the gate about one foot short of its fully closed position. After about one minute the gate should start closing and stop at its fully close limit. Set Power Fail switch S2 to the direction you desire the gate to move after a power outage. Rev B Doc 6001343 (01-20299) 13 of 40 L. Wire all external control devices to their connections on the control board as shown. See Appendix A for details on how each control input affects the gate operator. Master/Slave Installation Only: Connect Master/Slave interconnect cable (see Installation and Operation of X1 Series Master/Slave System, Doc. Disconnecting the STOP terminal from the COMMON terminal stops the gate and prevents all commands from having any effect. If gate(s) are used for bi-directional traffic, the Exit Loop should be a directional loop detector. Inside and Outside Interrupt Loops: For maximum safety, Inside and Outside Interrupt loops require separate loop detectors. If only one loop detector is used, the Outside loop must also be connected to the Inside loop detector. Master/Slave systems only: To enhance safety in Bi-Parting and Bi-Parting Latch Master/Slave systems, the Interrupt loops, Shadow loops and Interrupt Bar switches may be connected to both gates. If this is done, when connecting the two control boards, do not interchange input and common terminals. If terminals are interchanged, inputs will not be detected and controller boards may be damaged. If AC power to the controller board is cut off, the battery will retain the correct time and date. M. BASIC GATE OPERATOR PROGRAMMING Even if you plan to program the gate operator by telephone, you may want to enter some immediate instructions during installation. The following list of instructions will help you set basic controls so the gate will operate properly until you have time for full programming, either directly or by telephone. For complete programming instructions, refer to the enclosed manual SL 1000, SW 2000, BG 3000 and BG 3100-X1 Programming (-73 Bd), Doc. To access programming mode: enter 000000 (3 asterisks, 6 zeroes) To program a command: a) enter step number, b) enter required data, c) enter # (pound sign) To exit programming mode: enter 00# (2 zeroes, 1 pound sign) Step 01 02 03 04 05 06 07 08 09 10 11 13 14 15 Gate Type Operator Type Pair Type Warn When Warn Time Before Moving Anti-Tailgate Enable (ATG) Latch Delay Time Reclose Time (RT) Maximum Retry Count Retry Pause Time Reverse Sense Backup Inches Safety Bar Backup If Closing Safety Bar Backup If Opening Return to Factory Set Defaults Purpose # of Digits 1 1 1 1 2 1 3 Up to 3 1 Up to 2 Up to 3 Up to 3 Up to 3 6 Default 1 0 0 0 0 0 6 30 0 30 3 12 0 N/A Acceptable Input 0 = Slide, 1 = Swing, 2 = Barrier 0 = Single, 1 = Master, 2 = Slave 0= Bipart, 1=Latch, 2=Trap, 3=Tandem 0 = Moving, 1 = Closing, 2 = Not Closed, 3 = Alerts Only 0 ­ 30 Seconds 0 = Disabled, 1 = Enabled 0 ­ 250 Seconds (. 4 sec. Increments) 0 ­ 250 Seconds (0 = Disabled) 0 ­ 2 (0 = Do not retry) 30-99 Seconds 0 ­ 499 Inches See note below. 101010 (partial), 191919 (full) IMPORTANT NOTE: BARRIER GATE BACKUP DISTANCES Barrier gates move in degrees per second, so it is the length of the gate that determines how far the edge of the gate moves each second. [. . . ] Loop sensor: A wire embedded in the ground for magnetically sensing large metallic objects (cars). Interrupt or Reverse or Reopen Loop: activation reverses or stops the gate. Shadow Loop: activation prevents a fully open or close gate from moving while a vehicle is inside the arc of a swing gate. Loop detector: An electronic device that is activated by a loop sensor sensing a metallic object. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER BG3100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER BG3100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.