User manual LIFT-MASTER LA400

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER LA400. We hope that this LIFT-MASTER LA400 user guide will be useful to you.


LIFT-MASTER LA400 : Download the complete user guide (4750 Ko)

Manual abstract: user guide LIFT-MASTER LA400

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL MODEL LA400 MEDIUM DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # Primary Arm Serial # Secondary Arm Serial # Box Installation Date TABLE OF CONTENTS TABLE OF CONTENTS OPERATOR SPECIFICATIONS Tools Needed for Installation . . 4 WARNING Mechanical WARNING OPERATOR WARNINGS CAUTION Safety Installation Information . . 7 CAUTION WARNING WARNING Electrical WARNING CAUTION When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. [. . . ] The transformer can be plugged into a receptacle external to the control box. Alternatively, you can connect 120VAC directly to the box, and plug the transformer to the receptacle inside the control box. 120VAC POWER WIRE (STRANDED COPPER WIRE) Wire Gauge 16 10 Length 100' (30 m) 1000' (305 m) CONNECT ARM TO CONTROL BOX Connect the wires from the operator to connector P17 for the Gate 1 operator as shown in the wiring diagram on page 26. If connecting a second arm, follow the same instructions on connector P16. 24VAC TRANSFORMER (STRANDED COPPER WIRE) Wire Gauge 14 12 Length 500' (152 m) 1000' (305 m) Motor Wiring Power Wiring Control Wiring EARTH GROUND ROD INSTALLATION (OPTIONAL) When installing the optional earth ground rod, disconnect and remove the green/yellow ground wire connected to the screw terminal of the printed circuit board. For proper operation, Control Box the earth ground rod should not be connected to the ground of your power wiring. Ensure the power wiring ground connection remains securely connected to the Earth Ground 12 gauge green screw on the outlet Installation wire plate. Attach earth ground rod wire to the screw terminal of the printed circuit board marked . 13 WARNING CAUTION To AVOID damaging gas, power, or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18" (46 cm) deep. WARNING CONTROL WIRING P2 P1 R223 CAUTION J19 K6 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE J1 CLOSE EDGE R2Ø7 Z2Ø R227 To reduce the risk of FIRE or INJURY to persons, use ONLY Chamberlain part #K74-30762 for replacement batteries. ALARM NO C MAGLOCK K5 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 Z9 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING COM OVLD OVLD 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER BATT 2 B ATT 1 LOOP INPUTS R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 Q22 D22 SHADOW INTERRUPT CHGR OVLD F6 F2 D15 R4 C2 R196 COM 24 VAC/ SOLAR INPUT J4 F1 2ØA 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 BATTERY The main source of power for the operator is the batteries. The batteries can be charged in circuit by using a charging transformer or solar panels. 24 VAC/ SOLAR INPUT J4 MOV2 USE DEDICATED CIRCUIT CHARGING The 24VAC input can accept a charging transformer (26VAC, 29VA). OR SOLAR PANELS Optional solar panels may be used to charge the batteries. Solar Panels (LA400-SPK) must be a minimum of 27. 4V, 9W output. 14 BASIC CONTROL BOARD SETUP 20 19 17 26 1 P2 P1 R223 J19 K6 ALARM Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE J1 CLOSE EDGE R2Ø7 Z2Ø R227 14 MAGLOCK NO C K5 2 OPEN EDGE/ PHOTO 13 Z1 NO C NC 1 R2 L1 J18 U4 R224 Z22 R92 Z9 3 OPEN PHOTO O N S8 R1 10A 32V LEARN XMITTER 18 12 GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 4 CLOSE PHOTO DIAGNOSTIC R93 GATE 1 5 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 6* 22 7 ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING COM OVLD OVLD 11* 10 GATE 2 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED 10A 32V R1ØØ F4 SINGLE BUTTON ACCESSORY OVLD RESET STOP K4 F5 D21 K3 D8 MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 C12 D27 Z3 Z4 F7 C13 U3 C11 C4 LOOP INPUTS SHADOW INTERRUPT CHGR OVLD Q22 D22 8 COM D15 R4 C2 R196 F6 21 24 VAC/ SOLAR INPUT J4 F2 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 9 23 24 25 16 15 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 DESCRIPTION Connector P1 Connector P6 Connector P8 Connector P7 Connector P9 Connector P12 Connector P10 Connector P11 Connector P5 Connector P16 Connector P13 Connector P17 Connector P14 FUNCTION Antenna Input Close Edge Open Edge/Photo Open Photo Close Photo Switched Accessory Power* Control Inputs Loop Inputs 24Vac/Solar Input Gate 2 Accessory Power* Gate 1 Maglock/Solenoid ITEM 14 15 16 17 18 19 20 21 22 23 24 25 26 DESCRIPTION Connector P15 Connector Connector Dip Switch Pushbutton Pushbuttons Pushbutton Pushbuttons Pushbutton Potentiometer Potentiometer Potentiometer Connector FUNCTION Alarm Battery 1 Battery 2 S1 Learn Xmitter - Program Remote Gate 1 - Jog Learn Limit Learn Limits Gate 2 - Jog Learn Limit Single Button Force Bi-Part Delay Timer to Close Receiver *Maximum 300 mA combined output 15 SET DIP SWITCH FOR GATE TYPE 1. The Save switch must be set to the OFF position prior to setting or changing the switches. NOTE: When setting switches S2-5, the Save switch must be in the OFF position prior to setting or changing switches for the change to be saved. O N P2 P1 R223 J19 K6 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE CLOSE EDGE R2Ø7 Z2Ø R227 NO C MAGLOCK K5 OFF OFF SINGLE NO NO Z9 ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 S1 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING COM OVLD OVLD SINGLE BUTTON O N 24V R1Ø1 FORCE BIPART DELAY TIMER TO CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 LOOP INPUTS SHADOW INTERRUPT CHGR OVLD Q22 D22 OFF OFF SINGLE NO NO ON ON DUAL NC NC 12345 D15 R4 C2 R196 F6 COM 24 VAC/ SOLAR INPUT J4 F2 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 O N OFF OFF SINGLE NO NO ON ON DUAL NC NC 12345 16 PROGRAMMING REMOTE 1. Press remote button, the LED will flash, alarm output will activate twice. Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum). NOTE: For highest level of security, we recommend the Security® line of products. COMPATIBLE REMOTES - 315MHz PassportTM Remote CPT13 CPT23 CPT33 Security® Keyless Entry 376LM Security® Remotes 370LM 371LM 372LM 373LM 374LM R1 LEARN XMITTER 2 J19 K6 P2 P1 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE NO C MAGLOCK K5 NO C NC Z1 10A 32V L1 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 BRN GRN WHT YEL D1Ø K2 DIAGNOSTIC LiftM ast er BLU RED Z12 K1 Q9 GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WIRE STOP BUTTON (OPTIONAL) A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm). P2 P1 R223 J19 K6 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE CLOSE EDGE R2Ø7 Z2Ø R227 NO C MAGLOCK K5 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 Z9 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO CONTROL INPUTS OPEN GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING SINGLE BUTTON RESET STOP COM OVLD OVLD 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 COM LOOP INPUTS Q22 D22 SHADOW INTERRUPT CHGR OVLD F6 F2 COM POWER D15 R4 C2 R196 COM 24 VAC/ SOLAR INPUT J4 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 17 OPTIONAL CONTROL DEVICES SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence. Reset Control Input (N/O) The control box has a factory installed internal reset button. These terminals are intended for use with a single reset button that is installed within line of sight of the gate. Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input. PR ESE NC RE E LAY 2 Sa EXIT LOOP 5 62 ras ota X 62 SE NS FRE EQQ 5X IN DE MA A US OPEN COMMON AND/OR CONTROL INPUTS OPEN SINGLE BUTTON RESET STOP SINGLE BUTTON COMMON COM COM POWER AND/OR COMMON RESET P2 P1 R223 J19 K6 ALARM J1 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE CLOSE EDGE R2Ø7 Z2Ø R227 NO C MAGLOCK K5 NO C NC Z1 10A 32V OPEN EDGE/ PHOTO L1 J18 U4 R224 Z22 R92 Z9 1 R2 O N S8 R1 LEARN XMITTER GATE 1 2 F3 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO 12345 S1 OPEN PHOTO R91 R94 Z8 BRN GRN WHT YEL BLU RED Z12 K1 Q9 D1Ø K2 DIAGNOSTIC R93 CLOSE PHOTO GATE 1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS 24V SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON ACCESSORY POWER R9Ø GATE 2 TIMER RUNNING COM OVLD OVLD 24V R1Ø1 FORCE BIPART DELAY TIMER TO SINGLE BUTTON CLOSE BRN GRN WHT YEL BLU RED GATE 2 10A 32V R1ØØ F4 ACCESSORY OVLD K4 F5 D21 K3 D8 C12 RESET STOP MIN MAX OFF MAX OFF MAX COM COM POWER R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4 LOOP INPUTS SHADOW INTERRUPT CHGR OVLD Q22 D22 D15 R4 C2 R196 F6 COM 24 VAC/ SOLAR INPUT J4 F2 F1 20A 32V MOV2 MOV1 C64 JMPR2 U2 DB1 R9 D1 JMPR1 D6 D4 D2 FUSE OPEN BATT 2 BATT 1 18 LOOP INPUTS (P11) Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. [. . . ] Check the gate area to make sure all obstructions are removed. MAGLOCK DOES NOT WORK Maglock does not hold gates locked Check connections between the Maglock, its power supply, and the control board to make sure they are secure. Replace the control board. DIAGNOSTIC CODES # OF BLINKS 1 2 3 4 5 6 7 8 9 10 MEANING No Stop Switch Connected Gate 1 Arm Disengaged Gate 2 Arm Disengaged Both Gate Arms Disengaged RPM Reversal Force Reversal Processor Reset ROM Check Failed RAM Check Failed EEPROM Check Failed 28 REPAIR PARTS Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. CONTROL BOX LA400-CONT ITEM 1 2 3 4 5 6 7 8 Not Shown PART # K001A6039 K75-15480 K75-30764 K23-19380 K74-19499 K74-30762 K74-30763 K76-19446 K74-30941 DESCRIPTION Control Board Control Box & Cover with Gasket Control Board Bracket Reset Switch Antenna Battery Transformer Alarm ATC Fuse Kit Includes 20 Amp (1), 15 Amp (2) QTY 1 1 1 1 1 2 1 1 8 2 7 3 4 1 6 5 29 REPAIR PARTS ACTUATOR ARM KITS ITEM 1 2 3 4 Not Shown PART # 41ASWG-442SA 41ASWG-438SA 41ASWG-0014SA 41ASWG-454 41ASWG-0119 DESCRIPTION Release Lever Motor with Limit Switch Harness Rear Connector Cable 24V with Connector Release Key QTY 1 1 1 1 1 2 1 3 4 30 O P E R AT O R N O T E S 31 WARRANTY POLICY AND SERVICE LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LA400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LA400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.