User manual LIFT-MASTER MT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER MT. We hope that this LIFT-MASTER MT user guide will be useful to you.


LIFT-MASTER MT : Download the complete user guide (2618 Ko)

Manual abstract: user guide LIFT-MASTER MT

Detailed instructions for use are in the User's Guide.

[. . . ] FACTORY SET C2 Wiring See page 8 for other wiring configurations OWNER'S MANUAL MODEL MT MEDIUM DUTY DOOR OPERATOR 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intermittent duty HORSEPOWER: . . . . . . . . . . . . . . . . 1/2 Horsepower SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . 115V, 1 Phase, 60Hz 230V, 1 Phase, 50Hz CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate LIMIT ADJUST: . . . . . . . . . . . . . . . . Linear driven, fully adjustable screw type cams. WIRING TYPE: . . . . . . . . . . . . . . . . . C2 (Factory Shipped) Momentary contact to OPEN & STOP, constant pressure to CLOSE, plus wiring for sensing device to reverse. See page 8 for control wiring options. ELECTRICAL TRANSFORMER:. . . . . . . . . . . . . 24VAC CONTROL STATION: . . . . . NEMA 1 three button station. OPEN/CLOSE/STOP MECHANICAL DRIVE REDUCTION:. . . . . . . . . . . . . Primary: Heavy duty (4L) V-Belt. [. . . ] Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. W If other problems persist, call our toll-free number for assistance - 1-800-528-2806. CAUTION Sensor for Auxiliary Reversing System OPEN Limit Switch Retaining Plate CLOSE Limit Switch Aux. Close) Limit Switch 6 POWER WIRING CONNECTIONS Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. NING WARNING DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND PERMANENTLY WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. POWER WIRING 1. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Using the 1-1/16" dia conduit access hole as shown below, bring supply lines to the operator and connect wires to the terminals indicated on the WIRING CONNECTIONS DIAGRAM. DO NOT TURN POWER ON UNTIL YOU HAVE FINISHED MAKING ALL POWER AND CONTROL WIRING CONNECTIONS AND HAVE COMPLETED THE LIMIT SWITCH ADJUSTMENT PROCEDURE. TION WARNING WARNING TO AVOID DAMAGE TO DOOR AND OPERATOR, MAKE ALL DOOR LOCKS INOPERATIVE. IF THE DOOR LOCK NEEDS TO REMAIN FUNCTIONAL, INSTALL AN INTERLOCK SWITCH. WARNING IMPORTANT: THIS UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. IF CONTROL STATION CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. WARNING IMPORTANT: Mount WARNING NOTICE beside or below the push button station. Control Station MOUNT WARNING NOTICE OPEN CAUTION Push Buttons WARNING CLOSE WARNING STOP TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR WARNING Notice 8 CONTROL WIRING Radio Controls On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the radio transmitter. However, for complete door control from a transmitter, a commercial three-channel radio set (with connections for OPEN/CLOSE/STOP) is recommended. WARNING DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. IN ADDITION, IF A SINGLE CHANNEL CONTROL IS USED, THE USER WILL NOT BE ABLE TO STOP THE DOOR FROM THE TRANSMITTER. W CAUTION Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. [. . . ] OPEN-A CAPACITOR MOTOR * O/L Y R BK L2 BK L1 BR R BK CLOSE-C OPEN-C 3 STOP 4 MOVE JUMPER WIRE TO TERMINAL #2 FOR MOMENTARY CONTACT ON CLOSE BRAKE SOLENOID BL/BK PR1. R BL Y W R3 WIRE NUT HAND CHAIN INTERLOCK SW. 12 BL CLOSE-A C N. O. R BR R1 BR OR OPEN-B 1 OPEN SAFETY EDGE GY OPEN L. S. OR OP OR N. C. W C 11 AUX. BOARD (When Present) 5 W 4 3 2 1 Y PULL SWITCH OPEN & CLOSE 7 R TO Y R2 Y AUX. C W 2 * TO REVERSE MOTOR ROTATION INTERCHANGE RED AND YELLOW MOTOR WIRES. 14 WIRING DIAGRAM for BMT 1754 CLOSE W W COM OPEN OR P N. C. COM OR N. C. Y AUX. OPEN P N. O. N. C. AUX. CLOSE GY COM GY W Y BR R3 R2 R1 RADIO REC'R TO REVERSE MOTOR DIRECTION INTERCHANGE RED & YELLOW WIRES. RESISTOR MOTOR Y Y Y O/L BRAKE SOLENOID BR CAPACITOR R R R W PRIMARY R BK BL W BL/BK WIRE NUT BL/BK B NC NO C C NC NO C A W B NC NO C C NC NO C A BL BK OR BR XFMR Y SECONDARY OP BL/BK N. O. CL BL R P P Y COM ** INTLK. Y GY 5 4 3 2 1 R OR P BR Y Y GY W BL BK BK OR 1 2 3 4 7 10 11 12 L1 L2 GROUND See Close Control Wiring Options Below A. R. S. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER MT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER MT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.