User manual LIFT-MASTER ROBO SLIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER ROBO SLIDE. We hope that this LIFT-MASTER ROBO SLIDE user guide will be useful to you.


LIFT-MASTER ROBO SLIDE : Download the complete user guide (5768 Ko)

Manual abstract: user guide LIFT-MASTER ROBO SLIDE

Detailed instructions for use are in the User's Guide.

[. . . ] copyright © 2004 chamberlain professional products - www. eliteaccess. com TABLE OF CONTENTS 2 3 4-6 7 8 9 10 10 11 11 12 13 14 15 16 17 17 18 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33-34 35 35 36 36 37 38 39 40 41 Role of Specifiers. . . , Role of Dealers. . . . Role of End Users/Home Owners, Horizontal Slide Gate Systems Warnings and Precautions Safely Operating Gate Important Notice Configuration and Specifications Warnings and Precautions Step 1: Getting Started Step 2: Mounting Operator Step 3: Chain Installation Step 4: Gate Movement Direction Step 5: Earth Ground Rod Step 6: DC Power Supply Connection Step 7: "Optional" Solar Panel Step 8: Surge Suppression Terminal Connections Step 9: Adjusting Gate Travel Distance Step 10: Timer Step 11: 2-Way Adjustable Reversing Sensor Step 12: Mounting Warning Placards "Optional" Fire Release Box "Optional" Input Board Maglock Wiring Connection "Optional" 12 VDC Photocell Wiring 3-Push Button Wiring Connection 3-Push Button Wiring Master / Slave "Optional" Edge Sensor Wiring Single Operator Loop Size and Placement Master / Slave Loop Size and Placement Loop Installation and Number of Wire Turns Wiring Loop Detector to Operator Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions LED Descriptions Troubleshooting How to Reset Breaker Switch How to Check Fuses Gate will not close!If you hear a "BEEP" sound (Audio Alarm) Robo Slide Parts Robo Slide Parts List Elite Robo Slide Accessories Owners Checklist of Installation Please DO NOT Touch me!. . Unless you are an Authorized Service Technician! © COPYRIGHT 1992-2003 BY ELITE ACCESS SYSTEMS, INC. [. . . ] After the beeps, check the "Charge OK" LED. . . . . . it must be "ON". Motor Harness Alarm Sensor LED will flash 3 times during power connection. This means the board is OK. CHECK CHARGINGFUSE BOARD POWER POWER Beep!Beep! SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD HEAVY GATE POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA Battery Connected Only: Power LED on Transformer Connected Only: Power LED on Charge OK LED on CENTRAL CONT FIRE DEPT ROL OPEN STRIKE OPEN STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE 14 STEP BY STEP INSTALLATION STEP 7: Optional Solar Panel Connection If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the solar panel to the power input connection on the surge suppressor (Polarity does not matter). This solar panel will charge up to 1000 Mamp/Hr in optimum conditions & 300 Mamp/Hr in light overcast conditions. For further details about Elite's solar panel, consult the "Solar 3" Installation sheet that is included with the solar panel. ® ® CAUTION Do Not use solar panel and plug-in transformer at the same time. AC ­ AC ACCESS SYSTEMS INC R Solar Panel (Elite Part # SOLAR 3) No Stand POWER INPUT 18 VAC ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ + RADIO RECEIVER Polarity Does Not Matter POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON CLASS 2 SUPPLY Energizing this operator with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery . Elite recommends using a larger battery (12 VDC, 30 AHr) (Elite Part # A 12330) in this operator when using the optional solar panel. CAUTION 12 VDC r 30 AH For More Details, contact your Local Dealer 15 STEP BY STEP INSTALLATION STEP 8: Surge Suppressor Terminal Connections The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER CLASS 2 SUPPLY 4 Wire -12 VDC Radio Receiver To 115 VAC Polarity does NOT Matter 13 12 11 11 + Red Radio (+12 VDC) Grey Radio (Relay) ­ Black Radio (-) ­ Grey Radio (Relay) AC AC Plug-In Transformer 18 VAC 1 4 External "Safety" Loop Detector 12 VDC 10 9 Card Reader 10 9 Push Button 1 4 Photo Beam (Safety) 12 VDC 10 9 Phone Entry 1 4 7 HELP 2 5 8 0 3 6 9 5 6 External "Exit" Loop Detector 12 VDC 8 7 Fire or Any Key Switch 16 STEP BY STEP INSTALLATION STEP 9: Adjusting Gate Travel Distance Adjustment is done by limit switches which are located on the Robo Slide chassis. By pressing the plate down and spinning the adjustment nuts, set your limit switches for open and close cycles. Limit Switches Each notch of the nut indicates an estimated 1 inch of gate travel STEP 10: Timer If you want to use the automatic close for the gate system, the timer switch should be set to the "ON" position. If you want to use the push open or push close command, the timer should be set to the "OFF" position. CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON TIMER Set Timer 0 to 60 seconds UP PW STOP OVERLOAD POWER J2 ALARM SENSOR REVERSE SENSOR ON 60 OFF HEAVY GATE 0 CLOSE CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONT FIRE DEPT ROL OPEN STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC ON 60 OFF 0 TIMER ON UP PW STOP OPEN TO RIGH T 60 0 CLOSE OFF 17 W1 CLOSE STOP TIMER UP PW STEP BY STEP INSTALLATION STEP 11: Two-Way Adjustable Reversing Sensor Adjust the "Reverse Sensor" pot on the upper portion of the control board. The level of reverse sensitivity depends on the weight of the gate and the condition of installation. Not sensitive enough = if the gate hits an object and does not stop or reverse. Do Not Touch Alarm Sensor Pot Minimum Sensitivity HEAVY GATE CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Important Note! There is a "Heavy Gate" LED which will light up when the gate is heavier than normal. This is a diagnostic LED and the operator will still function normally when this indicator is on. SYSTEM ON ALARM SENSOR ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW REVERSE SENSOR OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO FIRE DEPT STRIKE OPEN L STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIGHT Maximum Sensitivity STEP 12: Warning placards need to be permanently mounted on BOTH sides of the gate. W1 OPEN NOW YOUR INSTALLATION IS COMPLETE 18 For Toll Free Technical Support: 1-888-ELITE-10 35483 "OPTIONAL" FIRE RELEASE BOX The "Fire Release Box", is designed for use on sliding gates. The doors can be locked with your own padlock, or the fire department's padlock. A steel cable with a t-handle runs from the box to the release mechanism at the rear end of the chain. The release mechanism, is placed where the chain bolt would normally be. To reset, simply reinsert the pin into the housing for normal operation. (Elite Part # A CP-17) Pull firmly on the "T" Handle to release the chain. Contact your local dealer for more information. The chain is held in place by a spring loaded pin. 19 "OPTIONAL" INPUT BOARD The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. [. . . ] Low battery Open relay is energized Close relay is energized If dimmed down 1. Bad Charging power fuse 3 Battery Low normally off - it will indicate low battery Battery OK Battery voltage is over minimum required limit 4 Heavy Gate will work only when the gate is in motion Gate weight and condition are OK 5 Open Relay 6 Close Relay 7 System On Open relay is not energized Close relay is not energized 1. No motor current detected will work only when the gate is in motion 8 Alarm Sensor Detecting motor current when LED goes on you will hear a "beep" sound for about 20 seconds LED will flash 3 times for "board OK" during power connection. 1. Unwanted object has physically stopped gate System is OK Note: Circled red numbers indicates location on control board, identified on page 32. 33 LED DESCRIPTION LED On - CONTINUED LED Off No obstruction is detected LED Description 9 Reversing Sensor Sensor is detecting obstruction 10 Central Control Acknowledgement of receiving open command from one of the surge suppressor terminals · Fire Department 7 & 8 · Strike Open 9 & 10 · Safety Loop 1&4 · Exit Loop 5&6 · Radio Receiver 11 & 12 Receiving signal at the surge suppressor terminal block 7&8 Receiving signal at the surge suppressor terminal block 9 & 10 Receiving signal at the surge suppressor terminal block 1&4 Receiving signal at the surge suppressor terminal block 5&6 Receiving signal at the surge suppressor terminal block 11 & 12 Not receiving any command 11 Fire Dept Not receiving signal at the surge suppressor terminal block 7 & 8 Not receiving signal at the surge suppressor terminal block 9 & 10 Not receiving signal at the surge suppressor terminal block 1 & 4 Not receiving signal at the surge suppressor terminal block 5 & 6 Not receiving signal at the surge suppressor terminal block 11 & 12 12 Strike Open 13 Safety Loop 14 Exit Loop 15 Radio Rec 16 Timer PW Timer power is on Timer is not on 17 Timer UP Output signal to close relay Not receiving signal to close relay Note: Circled red numbers indicates location on control board, identified on page 32. 34 TROUBLESHOOTING How to Reset the Breaker If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker will kick-out. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER ROBO SLIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER ROBO SLIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.