User manual LYNX C DA 3000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LYNX C DA 3000. We hope that this LYNX C DA 3000 user guide will be useful to you.


LYNX C DA 3000 : Download the complete user guide (844 Ko)

Manual abstract: user guide LYNX C DA 3000

Detailed instructions for use are in the User's Guide.

[. . . ] LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product. THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. [. . . ] Remote control interface. Page 7 Reference Manual C DA 3000 Version 2. 0 The module has a built in micro-controller with local controls, status and alarm indicators and well as internal flash ram for storing setups. Any operational parameters configured and stored into the module are recalled when powered up. Remote control and remote status monitoring is possible when used with the rack frame option and host controller. The C DA 3000 is part of the 3000 series of MiniModules, which offer high quality, modularity and flexibility in a very small form factor ideal for applications where space is at a premium. The modules can be used either stand alone using the optional power supply brick, or as part of a tightly integrated space saving system where up to 10 MiniModules can be mounted utilizing the optional LYNX R FR 3005 / 3010 rack housing. This includes integrated power supply and optional remote control interfaces. Page 8 Reference Manual C DA 3000 Version 2. 0 Functional Diagram Figure 1 below is the basic functional diagram for the C DA 3000 MiniModule. SDI LOOP 1 DRV SDI LOOP 2 SDI IN EQ PLL SER PAR G or Y B / U / Y (S) R / V / C (S) Color Bars DAC CVBS CVBS CVBS Remote Micro Controller Switch Alarm Status Figure 1- C DA 3000 Functional Diagram Module Layout Figure 2 shows the physical layout of the C DA 3000 MiniModule. Module configuration is set via a small dip-switch located behind an access hole in the bottom of the module. If the module is being used in a stand alone application then the optional power supply (R PS 3001 E, R PS 3001 U, R PS 3001-3 or R PS 3004) is required to power the module (not shown) Page 9 Reference Manual C DA 3000 Version 2. 0 Figure 2 ­ Module Layout Page 10 Reference Manual C DA 3000 Version 2. 0 Connections Video Connections The C DA 3000 MiniModule is configured with standard 75 Ohm BNC connectors. We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation. Due to the compact design of the module it will be necessary to use a connection tool to secure the BNC video connectors to the module. Page 11 Reference Manual C DA 3000 Version 2. 0 Power Connections If using the module in a stand-alone application use the separate R PS 3001 E (for Europe), R PS 3001 U (USA) power brick option, the R PS 3001-3 desk power supply or the R PS 3004 desk power supply for 4 MiniModules. DC Power Connector The MiniModule has a captive power lead fitted to the module, with a male 5 pin locking bayonet connector. This connection provides DC power and also data connectivity to the module. Connector wiring is shown below. Data Connection Power Connection i2C-SDA (data) i2C-SCL (clock) 4 5 3 2 1 GND + 5V Male Connector (view looking into connector from front) ! Page 12 Caution Only use the optional LYNX R PS power modules. Ensure the 5-pin power connector is locked securely in place. Reference Manual C DA 3000 Version 2. 0 Installation Mechanical Stand Alone Operation The C DA 3000 MiniModule can be used in a stand alone application. This allows up to any 10 of the MiniModules to be secured onto a rack frame assembly for 19 inch rack mounting. The rack frames are designed for installation in the back of 19-inch racks where there is normally plenty of available space. Ideal for mobile truck installations and facility expansions where space is at a premium. Page 14 Reference Manual C DA 3000 Version 2. 0 Electrical Installation. Stand Alone Operation The MiniModule requires the R PS 3001 power brick option for stand-alone operation. Four versions are available: R PS 3001 E for European markets, R PS 3001 U for the US markets, the R PS 3003-3 desk power supply or the R PS 3004 desk power supply for four MiniModules. The connection to the module is made with a small 5pin connector, which has a twist bayonet securing system. A strain relief is included within the module to prevent excessive strain on the connection. Signal connections should be made with care, please ensure connections are correct and compatible equipment is feeding / receiving the signals from the module or damage can result. ! [. . . ] This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 3010. This is a card cage with integrated central power supply, optional redundant power supply and optional controller, which can accommodate 10 MiniModules. Can be combined with R FR 3005 1. 5m cable extension to connect one MiniModule to R FR 3010 2. 5m cable extension to connect one MiniModule to R FR 3010 Redundant power supply for the R FR 3010 card cage Rack controller for the R FR 3010 rack frame Master controllerwith TCP/IP Interface for the R FR 3010 rack frame Rack Bus Extension for R FR 3010 rack frame. In combination with R CT 5020 Service Adapter for remote configuration of one MiniModule via PC or Palm R PS 3001 U R PS 3001-3 R PS 3004 R FR 3004 R FR 3005 R FR 3010 R PS C15 R PS C25 R PS 5010 R CT 5020 R CT 5030 R CT 5010 R CT 3000 Page 22 Reference Manual C DA 3000 Version 2. 0 Parts List Due to the very dense design and high level of integration there are no user serviceable electronic assemblies within the C DA 3000 module. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LYNX C DA 3000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LYNX C DA 3000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.