User manual MAXDATA MPL 2210R CASE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXDATA MPL 2210R CASE. We hope that this MAXDATA MPL 2210R CASE user guide will be useful to you.


MAXDATA MPL 2210R CASE : Download the complete user guide (8607 Ko)

You may also download the following manuals related to this product:

   MAXDATA MPL 2210R CASE (8541 ko)

Manual abstract: user guide MAXDATA MPL 2210R CASE

Detailed instructions for use are in the User's Guide.

[. . . ] MAXDATA PLATINUM 2210R Server Chassis User`s Manual 2 Contents Contents 1 Chassis Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Feature Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Chassis Front Panel and Peripheral Bays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chassis Back I/O Ports and Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Hard drive bays (6) Flex bay (1) DVD/CD-ROM drive/floppy disk drive module Tape drive Hard disk drive Hot Swappable SCSI Hard Drives The chassis ships with four drive carriers for mounting SCSI hard drives in the hard drive bays. When a drive fails, the SCSI backplane detects the failure, reports it, and powers down the failed drive. After the failed drive is removed and a new drive is inserted, there is a short wait before power is applied to the drive and the drive fault LED becomes a random blinking green light. NOTE Drives can consume up to 17W of power each. Drives must be specified to run at a maximum ambient temperature of 50°C. MAXDATA PLATINUM 2210R Server Chassis 9 Flex Bay The flex bay can be used with either the optional DVD/FDD module, CD-ROM/FDD module, or a seventh hot swappable SCSI HDD. The DVD/CD-ROM/FDD module may only be inserted or removed from the flex bay when system power is turned off. It is NOT hot swappable. 500 Watt Redundant Power Supply The power supply consists of the power supply bay and one power supply module. A second power supply module can be purchased to provide a redundant, 1+1 system. With either configuration, the power supply provides 500 W of power and is designed to minimize EMI. · Each kit contains instructions for installation into a rack or cabinet Equipment Rack Precautions CAUTION Anchor The Equipment Rack: The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The equipment rack must be installed according to the manufacturer's instructions. You must also consider the weight of any other device installed in the rack. Main AC Power Disconnect: You are responsible for installing an AC power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s). Grounding The Rack Installation: To avoid the potential for an electrical shock hazard, you must include a third wire safety grounding conductor with the rack installation. If server power cords are plugged into AC outlets that are part of the rack, then you must provide proper grounding for the rack itself. If server power cords are plugged into wall AC outlets, the safety grounding conductor in each power cord provides proper grounding only for the server. You must provide additional, proper grounding for the rack and other devices installed in it. Over Current Protection: The server is designed for an AC line voltage source with up to 20 amperes of over current protection. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server. If more than one server is installed in the rack, the power source for each server must be from a separate branch circuit. CAUTION Temperature: The operating temperature of the server, when installed in an equipment rack, must not go below 5°C (41°F) or rise above 35°C (95°F). Extreme fluctuations in temperature can cause a variety of problems in your server. Ventilation: The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling. [. . . ] While pushing on the tab, lift up on the module to clear the retention stub. Lift the fan module out of the chassis. Figure 12. Removing the Fan Blank MAXDATA PLATINUM 2210R Server Chassis 19 11. Insert the top of a new fan into the fan module and rotate the bottom in until tab (B) locks it in place. Figure 14. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXDATA MPL 2210R CASE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXDATA MPL 2210R CASE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.